GDC Group Brazilia F 5 Скачать руководство пользователя страница 9

Terminal Position with Minimum Distance 

(mm)

A* Directly below an openable window or other opening, e.g. an air brick. 300

B* Below gutters.

300

C* Below eaves, soil pipes or drain pipes.

300

D Below balconies or car port roof

600

E From vertical drain pipes and soil pipes.

300

F From internal or external corners.

600

G Above ground, roof or balcony level.

300

H From a surface facing a terminal.

600

I From a terminal facing a terminal.

600

J Vertically from a terminal on the same wall.

1500

K Horizontally from a terminal on the same wall.

300

L For an opening in a car port (e.g. door, window) into a dwelling.

1200

*In addition, the terminal should not be nearer than 300mm to an opening in the

building fabric formed for the purpose of accommodating a built-in element such

as a window frame or door frame (Fig. 8).

Fig. 5

Fig. 7

(side view). Angle of drop

shown exaggerated.

Fig. 8

3.3

Flue Position

1. The siting of the balanced flue terminal must

meet the following conditions:

a. Where the flue terminal of the appliance is

beneath any opening (that is to say, any part of a

window capable of being opened, or any

ventilation inlet or similar opening) no part of the

terminal shall be within 300mm (1 ft), measured

vertically from the bottom of the opening.

b. Where the flue terminal of the appliance is

less than 2m (6 ft) above the level of any ground,

balcony, flat roof or place to which any person

has access and which adjoins the wall in which

the flue terminal is situated, the terminal shall be

protected by a guard.

c. The guard must be screwed to the wall over

the flue terminal and be at least 50mm (2 in)

clear of any part of the terminal. A suitable guard

is available direct from the GDC Group service

dept., Part No. 080266 (Fig. 6).

d. Not within 300mm (1 ft) of ground level.

2. Fig. 4 shows the positioning of the flue

terminal relative to buildings and other

structures.

3. If the outer face of the outside wall is of

combustible material (timber, etc.) a metal or

other non-combustible material plate should be

fitted round the flue terminal so that it extends

not less than 50mm (2 in) around the terminal. A

179mm (7 in) square or a 230mm (9 in) diameter

circular plate will meet the requirement.

4. The flue should run horizontally, or with a

slight drop to the terminal, in order to prevent

rain entry (Fig. 7).

3.0 Site Requirements

Fig. 6

Installer Guide

9

Содержание Brazilia F 5

Страница 1: ...omfortstat 2 F 8ST Balanced Flue Gas Wall Heaters Installation and Owner Guide Please leave these instructions with the user 5131922 06 Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia...

Страница 2: ...m or database or transmitted in any form or by any means whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner Applications for the copyright...

Страница 3: ...roubleshooting 26 6 0 Warranty Service 27 28 7 0 Warning 27 Section Page s Contents Installer Before continuing any further with the installation of this appliance please read the following guide to m...

Страница 4: ...d flue arrangement Except for Comfortstat the appliance is controlled by a control knob which operates the ignition and alters the heat output The control knob has five positions giving a choice of th...

Страница 5: ...ons Failure to install the appliance correctly could lead to prosecution GAS SAFE REGISTER and CORGI require their members to work to recognised standards In the United Kingdom the installation must a...

Страница 6: ...ols Rotary thermostat allowing Comfortstat a lowt position and adjustment between low and high temperature settings Flame failure device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technic...

Страница 7: ...device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technical Data F 5 F 5S Propane When converted using kit No 5110284 Category of Appliance II2H3P The appliance is set for Gas Type G31 at...

Страница 8: ...de for Gas Installations in Timber Framed Dwellings 3 2 Clearances 1 The appliance must be fitted on a vertical flat non combustible wall Any combustible wall coverings should be removed from within t...

Страница 9: ...capable of being opened or any ventilation inlet or similar opening no part of the terminal shall be within 300mm 1 ft measured vertically from the bottom of the opening b Where the flue terminal of...

Страница 10: ...ntended for use in habitable rooms and must not be fitted in cupboards or confined compartments 3 6 Gas Supply 1 The inlet connection is located on the gas tap at the bottom right hand side of the app...

Страница 11: ...20mm 3 4in Adjust the distance from the back of the airbox and the joint between the terminal and air duct to this dimension Using the length of flue tape provided fix this dimension by taping up the...

Страница 12: ...ide are completed 1 Push in and turn the control knob back to the OFF position 2 On models not fitted with the Comfortstat control remove the knob from the appliance by gently pulling the knob forward...

Страница 13: ...xchanger casting If necessary clean the viewing window 14 With a light brush carefully remove deposits from the spark electrode burner flame ports and the burner gauze Fig 17 15 Replace the rope seal...

Страница 14: ...studs 2 Remove the three screws holding the burner retaining plate to the airbox and undo the thermocouple nut from the gas tap Fig 23 25 3 Ease the thermocouple and electrode leads from the rubber g...

Страница 15: ...ry aeration hole Fig 27 8 Reassemble in reverse order of dismantling 7 5 Injector 1 Remove the burner as described in sections 7 4 1 to 7 4 4 2 Undo the injector and sealing washer retaining the washe...

Страница 16: ...d undo the thermocouple nut from the gas tap Fig 31 33 3 Ease the thermocouple and electrode leads from the rubber grommet Fig 32 4 Disengage the burner from the injector and pull the electrode lead o...

Страница 17: ...to the burner inlet ensuring that it covers the primary aeration hole Fig 35 8 Reassemble in reverse order of dismantling 8 4 Injector 1 Remove the burner as described in sections 8 3 1 to 8 3 4 2 Und...

Страница 18: ...18 8 0 Fault Finding 3 5 0 5mm 7 1 5mm Fig 38 Ensure all installation criteria have been satisfied before performing Fault Finding e g flue terminal position Installer Guide...

Страница 19: ...enerator 042941 I 381941 Injector F 5 F 5S 224047 J 381942 Injector F 8S F 8ST 224104 K 205791 Washer For injector 082365 L 205844 Insulation F 5 F 5S 224048 M E01359 Insulation F 8S F 8ST 223971 N 15...

Страница 20: ...Owner Guide Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia F 8S...

Страница 21: ...covering adjacent to any heating appliance The likelihood of wall staining from convected air currents will be increased in environments where high levels of tobacco smoke or other contaminants exist...

Страница 22: ...gas to enter the burner ready for ignition Keep the knob pushed in for 20 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attem...

Страница 23: ...gnition Keep the knob pushed in for 10 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attempt to light the appliance may be req...

Страница 24: ...lish 3 2 Clearances 1 Internally the appliance must not be fitted under a shelf or sill that projects more than 150mm 6in 2 Curtains or a shelf must not be closer to the top of the outer case than 140...

Страница 25: ...ed for customers suffering from arthritis or similar conditions and provides the user with extra leverage when operating the control knob It is available from Spares Stockists 4 2 Running Costs 1 The...

Страница 26: ...ol knob not fully pushed in for sufficient period of time Keep the control knob pushed in for 20 secs and the burner should remain alight If not repeat the sequence Cold Start Up of Appliance Extreme...

Страница 27: ...ave the following information to hand 1 Fire serial number and fascia code Located on the information label See figure 4 on page 27 2 Date of installation 3 Your installer name and address details 4 F...

Страница 28: ...staller Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fax number Owner Guide Information label loca...

Отзывы: