GDC Group Brazilia F 5 Скачать руководство пользователя страница 13

6.0 Annual Servicing

6.1

Servicing the Appliance

1. For reasons of safety and economy the appliance

should be serviced annually.
2. Before servicing please read Section 1.3 Important

Information.
3. Turn off the gas supply and ensure that the appliance

is cold.
4. On models not fitted with the Comfortstat control,

remove the control knob by pulling forward. 
5. Remove the case by easing upward and forward until

it is clear of its retaining lugs.
6. Undo the heat exchanger retaining nuts and washers

(Fig. 16) and draw the casting forward off the locating

studs.
7. Remove the three screws holding the burner

retaining plate to the airbox and undo the thermocouple

nut from the gas tap (Fig. 17 & 20).
8. Ease the thermocouple and electrode lead from the

rubber grommet (Fig. 18).
9. Disengage the burner from the injector and pull the

electrode lead off the spark electrode (Fig. 17).
10. Check that the insulation is undamaged. Replace if

necessary

(Fig. 19).

11. Remove and clean the injector and sealing washer.

The injector must not be cleaned with a needle or wire

(Fig. 20). If the sealing washer is damaged it must be

replaced.
12. Check that the flue outlet tube is clear (Fig. 19).
13. Brush away any dirt from the heat exchanger

casting. If necessary clean the viewing window.
14. With a light brush carefully remove deposits from

the spark electrode, burner flame ports and the burner

gauze (Fig. 17).
15. Replace the rope seal in the heat exchanger casting

if it is damaged in any way  (Fig. 16). Also examine the

thermocouple and replace if necessary.
16. Re-assemble the injector, washer and burner

assembly in reverse order of dismantling. Ensure that

the spark gap is correct ie. 3.5mm ± 0.5mm. Check that

the burner is horizontal and correctly positioned on the

injector with the gauze covering the primary aeration

hole.
17. Check the gas pressure at the test point on the gas

control tap. If the pressure is not within the tolerance,

(see Section 2.0 Technical Data) the gas supply to the

unit needs to be investigated.
18. Check that the burner ignition is satisfactory. Ensure

that the thermocouple/electrode lead grommet is

correctly positioned and re-fit the heat exchanger

casting.
19. Check for gas soundness.
20. Fit the case and control knob (where applicable)

and re-check that the ignition is satisfactory.

Burner Retaining Plate

Injector

Thermocouple nut

Gas Tap

Electrode Lead

Washer

Grommet

Electrode Lead

Thermocouple wires

Burner Flame Ports

Spark 

Electrode

Burner Gauze

Flue Outlet Tube

Insulation

Heat Exchanger Casting

Rope Seal

Outer Case

Control Knob

Fig. 15

Fig. 16

Fig. 17

Fig. 18

Fig. 19

Fig. 20

Installer Guide

13

Содержание Brazilia F 5

Страница 1: ...omfortstat 2 F 8ST Balanced Flue Gas Wall Heaters Installation and Owner Guide Please leave these instructions with the user 5131922 06 Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia...

Страница 2: ...m or database or transmitted in any form or by any means whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner Applications for the copyright...

Страница 3: ...roubleshooting 26 6 0 Warranty Service 27 28 7 0 Warning 27 Section Page s Contents Installer Before continuing any further with the installation of this appliance please read the following guide to m...

Страница 4: ...d flue arrangement Except for Comfortstat the appliance is controlled by a control knob which operates the ignition and alters the heat output The control knob has five positions giving a choice of th...

Страница 5: ...ons Failure to install the appliance correctly could lead to prosecution GAS SAFE REGISTER and CORGI require their members to work to recognised standards In the United Kingdom the installation must a...

Страница 6: ...ols Rotary thermostat allowing Comfortstat a lowt position and adjustment between low and high temperature settings Flame failure device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technic...

Страница 7: ...device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technical Data F 5 F 5S Propane When converted using kit No 5110284 Category of Appliance II2H3P The appliance is set for Gas Type G31 at...

Страница 8: ...de for Gas Installations in Timber Framed Dwellings 3 2 Clearances 1 The appliance must be fitted on a vertical flat non combustible wall Any combustible wall coverings should be removed from within t...

Страница 9: ...capable of being opened or any ventilation inlet or similar opening no part of the terminal shall be within 300mm 1 ft measured vertically from the bottom of the opening b Where the flue terminal of...

Страница 10: ...ntended for use in habitable rooms and must not be fitted in cupboards or confined compartments 3 6 Gas Supply 1 The inlet connection is located on the gas tap at the bottom right hand side of the app...

Страница 11: ...20mm 3 4in Adjust the distance from the back of the airbox and the joint between the terminal and air duct to this dimension Using the length of flue tape provided fix this dimension by taping up the...

Страница 12: ...ide are completed 1 Push in and turn the control knob back to the OFF position 2 On models not fitted with the Comfortstat control remove the knob from the appliance by gently pulling the knob forward...

Страница 13: ...xchanger casting If necessary clean the viewing window 14 With a light brush carefully remove deposits from the spark electrode burner flame ports and the burner gauze Fig 17 15 Replace the rope seal...

Страница 14: ...studs 2 Remove the three screws holding the burner retaining plate to the airbox and undo the thermocouple nut from the gas tap Fig 23 25 3 Ease the thermocouple and electrode leads from the rubber g...

Страница 15: ...ry aeration hole Fig 27 8 Reassemble in reverse order of dismantling 7 5 Injector 1 Remove the burner as described in sections 7 4 1 to 7 4 4 2 Undo the injector and sealing washer retaining the washe...

Страница 16: ...d undo the thermocouple nut from the gas tap Fig 31 33 3 Ease the thermocouple and electrode leads from the rubber grommet Fig 32 4 Disengage the burner from the injector and pull the electrode lead o...

Страница 17: ...to the burner inlet ensuring that it covers the primary aeration hole Fig 35 8 Reassemble in reverse order of dismantling 8 4 Injector 1 Remove the burner as described in sections 8 3 1 to 8 3 4 2 Und...

Страница 18: ...18 8 0 Fault Finding 3 5 0 5mm 7 1 5mm Fig 38 Ensure all installation criteria have been satisfied before performing Fault Finding e g flue terminal position Installer Guide...

Страница 19: ...enerator 042941 I 381941 Injector F 5 F 5S 224047 J 381942 Injector F 8S F 8ST 224104 K 205791 Washer For injector 082365 L 205844 Insulation F 5 F 5S 224048 M E01359 Insulation F 8S F 8ST 223971 N 15...

Страница 20: ...Owner Guide Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia F 8S...

Страница 21: ...covering adjacent to any heating appliance The likelihood of wall staining from convected air currents will be increased in environments where high levels of tobacco smoke or other contaminants exist...

Страница 22: ...gas to enter the burner ready for ignition Keep the knob pushed in for 20 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attem...

Страница 23: ...gnition Keep the knob pushed in for 10 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attempt to light the appliance may be req...

Страница 24: ...lish 3 2 Clearances 1 Internally the appliance must not be fitted under a shelf or sill that projects more than 150mm 6in 2 Curtains or a shelf must not be closer to the top of the outer case than 140...

Страница 25: ...ed for customers suffering from arthritis or similar conditions and provides the user with extra leverage when operating the control knob It is available from Spares Stockists 4 2 Running Costs 1 The...

Страница 26: ...ol knob not fully pushed in for sufficient period of time Keep the control knob pushed in for 20 secs and the burner should remain alight If not repeat the sequence Cold Start Up of Appliance Extreme...

Страница 27: ...ave the following information to hand 1 Fire serial number and fascia code Located on the information label See figure 4 on page 27 2 Date of installation 3 Your installer name and address details 4 F...

Страница 28: ...staller Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fax number Owner Guide Information label loca...

Отзывы: