4. OPERATION
4.1 Power ON/OFF
4.2 Opera�on and Display Panel
The opera�on and display panel, shown in below chart, is on the front panel of the inverter.
It includes four indicators, four func�on keys and a LCD display, indica�ng the opera�ng status
and input/output power informa�on.
Chart 4-1 LED indicators
LED Indicator
DC
AC
Normal
Alarm
Green led solid light
Green led solid light
Green led solid light
Red led solid light
PV Connec�on normal
Grid Connec�on normal
Inverter opera�ng normal
Malfunc�on or warning
Messages
Chart 4-2 Func�on Bu�ons
Function Key
Esc
Up
Down
Enter
Description
To exit se�ng mode
To go to previous selec�on
To go to next selec�on
To confirm the selec�on
- 24 -
Once the unit has been properly installed and the ba�eries are connected well, simply press
On/Off bu�on(located on the le� side of the case) to turn on the unit. When system without
ba�ery connected, but connect with either PV or grid, and ON/OFF bu�on is switched off, LCD
will s�ll light up(Display will show OFF), In this condi�on, when switch on ON/OFF bu�on and
select NO ba�ery,system can s�ll working.(NOTE: Choose the correct country code. (refer to
sec�on 5.8 of this manual) No�ce: Different distribu�on network operators in different countries
have different requirements regarding grid connec�ons of PV grid connected inverters.
Therefore, it's very important to make sure that you have selected the correct country code
according to requirements of local authority. Please consult qualified electrical engineer or
personnel from electrical safety authori�es about this.)