GCL System Integration Technology Co., Ltd.
Bring Green Power to Life
18
MECHANICAL INSTALLATION
The Modules may be installed and fixed with the following methods:
Mounting hole system: Use the corrosion-resistant M8 bolt, for fixing with the
installation support through the installation hole in the side frame of the module, as
shown in Fig. 5.
Clamping system: use proper clamp, and fix the module with the installation support, as
shown in Fig. 6.
Figure 5 Mounting holes
Figure 6 Mounting clamps
The mounting accessories recommended are listed below:
Bolt
Flat washer
Spring washer
Nut
Material: stainless
Steel material: stainless steel
Material: stainless steel
Material: stainless steel
Size: M8
Size: M8
Size: M8
Size: M8
The range of torque for screw tightening is 14N.m to 20N.m.