GCL System Integration Technology Co., Ltd.
Bring Green Power to Life
9
MECHANICAL INSTALLATION
Installation Method
1
、
Modules without frames
Installation with the mounting clamp
Table 2 Installation Method
Clamping
on the
long side
Installation Method A
Installation Method B
Table 3 Installation method and load capacity
Module Type
Module
dimensions
(mm)
Length of
the clamp
(
mm
)
Installation Method A
Installation Method B
Position of
clamp K
(mm)
Design load :
downward/
upward,
γm=1.5
(
Pa
)
Position of
clamp K
(mm)
Design load :
downward/
upward,
γm=1.5
(
Pa
)
GCL-P6/60GDXXX
GCL-M6/60GDXXX
1658*992*6
150
300-400
2400
1600
300-400
3600
1600
1680*1000*6
GCL-N6/60GXXX
1658*992*6
150
300-400
2400
1600
300-400
3600
1600
GCL-P6/72GDXXX
GCL-M6/72GDXXX
1968*992*6
200
400-500
2400
1600
400-500
3600
1600
2000*1000*6
GCL-N6/72GXXX
1968*992*6
200
400-500
2400
1600
400-500
3600
1600
GCL-P3/60GDXXX
GCL-M3/60GDXXX
1700*1000*6
150
300-400
2400
1600
300-400
3600
1600
GCL-P3/72GDXXX
GCL-M3/72GDXXX
2030*1000*6
200
400-500
2400
1600
400-500
3600
1600
GCL-M/P3/60GTXXX
1700*1034*6
150
300-400
2400
1600
300-400
3600
1600
GCL-M10/60GTXXX
1980*1166*6
200
400-500
2400
1600
400-500
3600
1600
Note:
Test load = γm(
safety factors)
× design load