GCI E84 Emulator Getting Started Manual

Version 2.4a

GCI E84 Emulator Getting Started Manual

5

To Zoom In:  Right-Click and drag to select Zoom Window

10:30:54 - 09/25/2000

Recorded E84 Signals

Test Area : Get Control, Inc.

Ref Voltage :  1.8 Volts

Tested By : AJG

Load Port # : 

Active Eq. Mfg : Get Control, Inc.

Passive Eq. Mfg :  Get Control, Inc.

Active Eq. Model : E84 Emulator 1

Passive Eq. Model : E84 Emulator 2

TA1 - TA3 : 2, 2, 2

TP1 - TP5 : 2, 2, 60, 60, 2

    Time      Signal  St

------------  ------  --

      03.853  CS_0     1
      03.991  VALID    1
      05.788  L_REQ    1
      05.990  TR_REQ   1
      06.653  READY    1
      06.897  BUSY     1
      35.881  L_REQ    0
      36.086  BUSY     0
      36.152  TR_REQ   0
      36.287  COMPT    1
      36.829  READY    0
      37.054  COMPT    0
      37.154  VALID    0
      37.254  CS_0     0

0

10

20

30

40

50

Single Handoff Example

L_REQ 

U_REQ 

READY 

CS_0 

CS_1 

VALID 

TR_REQ 

BUSY 

COMPT 

CONT 

HO_AVBL 

ES 

Example Single Handoff Mode Transfer

To Zoom In:  Right-Click and drag to select Zoom Window

10:35:03 - 09/25/2000

Recorded E84 Signals

Test Area : Get Control, Inc.

Ref Voltage :  1.8 Volts

Tested By : AJG

Load Port # : 

Active Eq. Mfg : Get Control, Inc.

Passive Eq. Mfg :  Get Control, Inc.

Active Eq. Model : E84 Emulator 1

Passive Eq. Model : E84 Emulator 2

TA1 - TA3 : 2, 2, 2

TP1 - TP5 : 2, 2, 60, 60, 2

    Time      Signal  St

------------  ------  --

      03.273  CS_0     1
      03.273  CS_1     1
      03.411  VALID    1
      04.865  L_REQ    1
      05.115  TR_REQ   1
      05.756  READY    1
      06.021  BUSY     1
      40.282  L_REQ    0
      40.508  BUSY     0
      40.550  TR_REQ   0
      40.692  COMPT    1
      41.067  READY    0
      41.251  COMPT    0
      41.352  VALID    0
      41.452  CS_0     0
      41.452  CS_1     0

0

10

20

30

40

50

Simultaneous Handoff Example

L_REQ 

U_REQ 

READY 

CS_0 

CS_1 

VALID 

TR_REQ 

BUSY 

COMPT 

CONT 

HO_AVBL 

ES 

Example Simultaneous Handoff Mode Transfer

E84 Handoff Modes

The SEMI

®

 E84 Specification defines three types of handoff modes, Single, Simultaneous, and

Continuous.  The 

E84 Emulator

 supports all three handoff modes.  This section briefly describes each

mode, and explains the associated testing capabilities of the 

E84 Emulator

Single Handoff Mode

Single Handoff Mode is used to transfer a single carrier to or from a Load Port.  The AMHS equipment
defines the target Load Port at the beginning of the handoff sequence, using one of the Load Port select
signals (CS_0, CS_1).  Only one of the two signals is activated during the handoff sequence.

The figure at right shows E84 interface signals recorded
during a typical Single Handoff Mode transfer.  The
timing diagram shows the CS_0 signal turning ON to
indicate a Single Handoff Mode transfer.

The 

E84 Emulator Application

 provides 17 active

mode tests (Emulator acts as the active equipment) that
can be run using Single Handoff Mode.  These tests are
selectable from the 

Active Mode Test Setup Screen

,

which can be reached from the 

Main Menu

 using the

Automatic Active Mode Testing button.  To configure a
Single Handoff Mode test, simply select either the CS_0
or CS_1 button from the 

LOAD PORT NUMBER

 field on the

Active Mode Test Setup Screen

.

The 

E84 Emulator Application

 provides 15 passive mode tests (Emulator acts as the passive equipment)

that can be run using Single Handoff Mode.  These tests are selectable from the 

Passive Mode Test Setup

Screen

, which can be reached from the 

Main Menu

 using the Automatic Passive Mode Testing button. 

The active equipment sets the Load Port select signals.  Therefor, in passive mode testing there are no
Load Port select options.  The Emulator simply provides the proper transfer handshaking, while monitoring
and verifying the Load Port select signals detected at the beginning of the transfer.

Simultaneous Handoff Mode

Simultaneous Handoff Mode is used to transfer two carriers concurrently to or from two separate Load
Ports.  The AMHS equipment indicates a Simultaneous Handoff by setting 

both

 Load Port select signals

(CS_0 and CS_1).  Both signals remain activated during the handoff sequence.

The figure at right shows E84 interface signals recorded
during a typical Simultaneous Handoff Mode transfer. 
The timing diagram shows the CS_0 and CS_1 signals
turning ON, indicating a Simultaneous Handoff Mode
transfer.

The 17 active mode tests provided by the 

E84

Emulator Application

 can be run in Simultaneous

Handoff Mode as well as Single Handoff Mode.  The
only difference between Single and Simultaneous
Handoff Modes is the use of the two Load Port select
signals.  This allows the 

E84 Emulator Application

 to

use the same pre-defined tests to verify both Single and
Simultaneous Handoff sequences.  To configure a
Simultaneous Handoff Mode test, simply select the
Simultaneous button from the 

LOAD PORT NUMBER

 field on the 

Active Mode Test Setup Screen

.

Содержание E84

Страница 1: ...GCI E84 Emulator Getting Started Version 2 4a...

Страница 2: ......

Страница 3: ...d Test Setup Screens 7 Select Default Tests Button 8 Select Unload Port Tests Button 8 De Select All Tests Button 8 Test Setup Option Buttons 8 Continuous Handoff Test Setup Screen 9 Defining the Cont...

Страница 4: ...ssive Equipment Female DB 25 connector 4 Example Single Handoff Mode Transfer 5 Example Simultaneous Handoff Mode Transfer 5 Example Continuous Handoff Mode Transfer 6 Main Menu 7 Automated Active Mod...

Страница 5: ...ndoff sequences are supported including Single Simultaneous and Continuous modes E84 Emulator Application Version 2 4a requires a USB Interface E84 Emulator whose hardware has been updated to version...

Страница 6: ...tory within the C Program Files or C Program Files x86 directory structure is not recommended and may cause unexpected application behavior When installation is complete a dialog box is displayed indi...

Страница 7: ...module It is labeled PC INTERFACE Powering Up the E84 Emulator Plug the provided standard power cord into the E84 Emulator and into a 100V 240V AC wall outlet Turn the power switch on The power switch...

Страница 8: ...lower left of the Main Menu It will display Communications Mode USB when the E84 Emulator Application is properly communicating with the E84 Emulator USB Interface When the user attempts to use any o...

Страница 9: ...doff sequence The figure at right shows E84 interface signals recorded during a typical Single Handoff Mode transfer The timing diagram shows the CS_0 signal turning ON to indicate a Single Handoff Mo...

Страница 10: ...1 VALID TR_REQ BUSY COMPT CONT HO_AVBL ES Example Continuous Handoff Mode Transfer The 15 passive mode tests provided by the E84 Emulator Application can be also run in Simultaneous Handoff Mode as we...

Страница 11: ...e Active entity Attach the female end of a straight through 25 pin male to female cable provided to the DB 25 connector labeled EMULATOR IS ACTIVE EQUIPMENT on the E84 Emulator Attach the male end of...

Страница 12: ...s to run This provides a quick method of selecting all tests For Passive Mode testing this is the only function of the Select Default Tests button For Active Mode testing this button has one additiona...

Страница 13: ...the end of this manual Defining the Continuous Mode Test Sequence List A DEFINE CONTINUOUS MODE TEST SEQUENCE box allows the user to define the specific order of handoff s to run during Continuous Han...

Страница 14: ...one step in the SELECTED CYCLES list The bottom button displayed as a downward pointing arrow moves the selected cycle down one step in the SELECTED CYCLES list Default Cycles Buttons A set of Defaul...

Страница 15: ...sage Continuous Handoff Mode testing involves running several separate handoff s sequentially An typical Continuous Handoff Mode test might first Unload the carrier on Load Port CS_0 then load a new c...

Страница 16: ...Pass Fail status of the test based on feedback unavailable to the E84 Emulator from the equipment being tested For example when testing passive equipment timeout settings the E84 Emulator will force...

Страница 17: ...t signals The Passive Mode Manual Control Screen allows toggling of all Passive E84 output signals The screen also displays the live status of the Active equipment s output signals No automated timing...

Страница 18: ...evious versions did not monitor the ES signal during timeout and port sensor tests This falsely passed load ports that dropped ES along with HO_AVBL on timeout errors This change properly implements t...

Страница 19: ...on numbers in your email along with the following details The Test Mode Active Passive or Continuous you are running The Test Number and State where the problem is occurring Any Error messages display...

Отзывы: