GCI E84 Emulator Getting Started Manual

Version 2.4a

GCI E84 Emulator Getting Started Manual

6

To Zoom In:  Right-Click and drag to select Zoom Window

10:26:08 - 09/25/2000

Recorded E84 Signals

Test Area : Get Control, Inc.

Ref Voltage :  1.8 Volts

Tested By : AJG

Load Port # : 

Active Eq. Mfg : Get Control, Inc.

Passive Eq. Mfg :  Get Control, Inc.

Active Eq. Model : E84 Emulator 1

Passive Eq. Model : E84 Emulator 2

TA1 - TA3 : 2, 2, 2

TP1 - TP5 : 2, 2, 60, 60, 2

    Time      Signal  St

------------  ------  --

      04.904  CS_0     1
      05.039  VALID    1
      06.814  U_REQ    1
      07.039  TR_REQ   1
      08.324  READY    1
      08.554  BUSY     1
      08.554  CONT     1
      30.699  U_REQ    0
      30.929  BUSY     0
      30.978  TR_REQ   0
      31.117  COMPT    1
      31.606  READY    0
      31.780  COMPT    0
      31.880  VALID    0
      31.980  CS_0     0
      34.823  CS_0     1
      34.960  VALID    1
      35.868  L_REQ    1
      36.069  TR_REQ   1
      36.778  READY    1
      36.960  BUSY     1
   01:00.505  L_REQ    0
   01:00.740  BUSY     0
   01:00.783  TR_REQ   0
   01:00.928  COMPT    1
   01:01.386  READY    0
   01:01.584  COMPT    0
   01:01.684  VALID    0
   01:01.785  CS_0     0

0:00:00.0000

0:00:28.0000

0:00:56.0000

0:01:24.0000

0:01:52.0000

0:02:20.0000

Continuous Handoff Example

L_REQ 

U_REQ 

READY 

CS_0 

CS_1 

VALID 

TR_REQ 

BUSY 

COMPT 

CONT 

HO_AVBL 

ES 

Example Continuous Handoff Mode Transfer

The 15 passive mode tests provided by the 

E84 Emulator Application

 can be also run in Simultaneous

Handoff Mode as well as Single Handoff Mode. 

Continuous Handoff Mode

Continuous Handoff Mode is used to transfer multiple carriers sequentially to or from a specific Load Port. 
The AMHS equipment indicates a Continuous Handoff by setting the CONT signal during the first carrier
handoff, at the time the BUSY signal is turned ON.  The AMHS keeps the CONT signal ON through
subsequent carrier handoff’s, turning it OFF during the last carrier handoff.  

The figure at right shows E84 interface signals recorded
during a typical Continuous Handoff Mode transfer.  The
timing diagram shows a four carrier, Continuous
Handoff sequence: Unload CS_0, Load CS_0, Unload
CS_1, Load CS_1.  Note how the CONT signal turns
ON during the first carrier handoff, and remains ON until
the last carrier handoff. 

The 

E84 Emulator Application

 provides three

Continuous Handoff Mode tests; two active mode, and
one passive mode.  These tests are selectable from the

Continuous Mode Test Setup Screen

, which can be

reached from the 

Main Menu

 using the Continuous

Mode Testing button.

Содержание E84

Страница 1: ...GCI E84 Emulator Getting Started Version 2 4a...

Страница 2: ......

Страница 3: ...d Test Setup Screens 7 Select Default Tests Button 8 Select Unload Port Tests Button 8 De Select All Tests Button 8 Test Setup Option Buttons 8 Continuous Handoff Test Setup Screen 9 Defining the Cont...

Страница 4: ...ssive Equipment Female DB 25 connector 4 Example Single Handoff Mode Transfer 5 Example Simultaneous Handoff Mode Transfer 5 Example Continuous Handoff Mode Transfer 6 Main Menu 7 Automated Active Mod...

Страница 5: ...ndoff sequences are supported including Single Simultaneous and Continuous modes E84 Emulator Application Version 2 4a requires a USB Interface E84 Emulator whose hardware has been updated to version...

Страница 6: ...tory within the C Program Files or C Program Files x86 directory structure is not recommended and may cause unexpected application behavior When installation is complete a dialog box is displayed indi...

Страница 7: ...module It is labeled PC INTERFACE Powering Up the E84 Emulator Plug the provided standard power cord into the E84 Emulator and into a 100V 240V AC wall outlet Turn the power switch on The power switch...

Страница 8: ...lower left of the Main Menu It will display Communications Mode USB when the E84 Emulator Application is properly communicating with the E84 Emulator USB Interface When the user attempts to use any o...

Страница 9: ...doff sequence The figure at right shows E84 interface signals recorded during a typical Single Handoff Mode transfer The timing diagram shows the CS_0 signal turning ON to indicate a Single Handoff Mo...

Страница 10: ...1 VALID TR_REQ BUSY COMPT CONT HO_AVBL ES Example Continuous Handoff Mode Transfer The 15 passive mode tests provided by the E84 Emulator Application can be also run in Simultaneous Handoff Mode as we...

Страница 11: ...e Active entity Attach the female end of a straight through 25 pin male to female cable provided to the DB 25 connector labeled EMULATOR IS ACTIVE EQUIPMENT on the E84 Emulator Attach the male end of...

Страница 12: ...s to run This provides a quick method of selecting all tests For Passive Mode testing this is the only function of the Select Default Tests button For Active Mode testing this button has one additiona...

Страница 13: ...the end of this manual Defining the Continuous Mode Test Sequence List A DEFINE CONTINUOUS MODE TEST SEQUENCE box allows the user to define the specific order of handoff s to run during Continuous Han...

Страница 14: ...one step in the SELECTED CYCLES list The bottom button displayed as a downward pointing arrow moves the selected cycle down one step in the SELECTED CYCLES list Default Cycles Buttons A set of Defaul...

Страница 15: ...sage Continuous Handoff Mode testing involves running several separate handoff s sequentially An typical Continuous Handoff Mode test might first Unload the carrier on Load Port CS_0 then load a new c...

Страница 16: ...Pass Fail status of the test based on feedback unavailable to the E84 Emulator from the equipment being tested For example when testing passive equipment timeout settings the E84 Emulator will force...

Страница 17: ...t signals The Passive Mode Manual Control Screen allows toggling of all Passive E84 output signals The screen also displays the live status of the Active equipment s output signals No automated timing...

Страница 18: ...evious versions did not monitor the ES signal during timeout and port sensor tests This falsely passed load ports that dropped ES along with HO_AVBL on timeout errors This change properly implements t...

Страница 19: ...on numbers in your email along with the following details The Test Mode Active Passive or Continuous you are running The Test Number and State where the problem is occurring Any Error messages display...

Отзывы: