APPLICATION: 

The AB Formulator is designed to be a unique water formulation 

and water filtration system.  Incoming water TDS levels are filtered 

and then formulated to specific TDS standards set at the factory, 

which is preferred by most customers.  The unit is compact with 

a  space  saving  rectangular  water  storage  tank.    The  Manifold 

provides  for  separate  connections  to  espresso/brewer  machine 

and ice machine.  The Manifold can be located on the left or right 

top side of the unit.  Pressure gauges are mounted on the front 

of the unit along with the bypass valve for easy monitoring.  The 

System  Control  Box  is  located  on  the  front  of  the  unit  as  well. 

Minerals can be added back into feed water of a Reverse Osmosis 

(RO) system or where the TDS levels are low, using The Formula.  

Created  by  Globals  R  &  D  team,  The  Formula  utilizes  a  specific 

combination of food grade mineral salts to bring the right blend of 

TDS and hardness for a great brew as well as valuable equipment 

protection.  The AB Formulator uses the same 18” x 24” footprint 

as many Global Reverse Osmosis (RO) systems; a Global standard 

known to many industries.

OPERATING PARAMETERS:

Open Flow Rate ............................................

4.5 GPM (17.034 LPM)

Service Flow Rate

 ..................................................

3 GPM (1.4 LPM)

Storage Tank Capacity

 ...............................

18 Gallons (128.7 Liters)

Maximum volume .............................................

Minimum 720 GPD

Output Pressure .....................................................

40 PSI (2.76 bar)

FEED WATER and POWER REQUIREMENTS:

Pressure ..................................................

40 to 90 PSI (2.7- 6.2 bars)

Temperature .........................................................

50-80°F (10-26°C)

Max TDS  .............................................................................

125 ppm

Maximum Chlorine ...............................................

1 ppm (1.0 mg/L)

Electrical*

 .................................

110 vac. 50/60 hz, 3 amps (0.7kVA)

* Power conversion required if 220 V or higher

Sound Emission ..............................................................

<50dB max

SIZE/WEIGHT:

 

Height (with wheels) ...........................................

 43” (1,092.2 mm)

Width  ......................................................................

19” (482.6 mm)

Depth 24” 

 ..................................................................

25” (635 mm)

Ship weight ..............................................................

 93 lbs (42.2 kg)

 

Wet weight .........................................................

255 lbs (115.74 kg)

PERFORMANCE DATA:

• Recommended set point of 150 ppm

• TDS 4 - 5 grains hardness

• The Formula Mineral Concentrate:

       1 Gallon = 3200 Gallons Formulated Water

       2.5 Gallons = 8000 Gallons Formulated Water

WARNING:

Do not use where water is microbiologically unsafe or of unknown 

quality. Replacement components are to be manufactured or ap

-

proved by Global Customized Water to maintain efficiencies. Sys

-

tem is to be serviced at prescribed time/usage intervals according 

to this document, to maintain warranty.

 

Easy AB Formulator - Unit Guide

 

     

Page 3

Содержание Easy Series

Страница 1: ...info gcwater com 20 Opportunity Road Camdenton MO 65020 805 484 1589 www GlobalCustomizedWater com Easy AB Formulator Reverse Osmosis and Remineralization Unit Guide...

Страница 2: ...R P O S ES W I T H O U T S P EC I F I C W R I T T E N P E R M I S S I O N F RO M G LO BA L C U STO M I Z E D WAT E R Table of Contents Troubleshooting Guide Routine System Check Guide Production Rate...

Страница 3: ...footprint as many Global Reverse Osmosis RO systems a Global standard known to many industries OPERATING PARAMETERS Open Flow Rate 4 5 GPM 17 034 LPM Service Flow Rate 3 GPM 1 4 LPM Storage Tank Capac...

Страница 4: ...th the air gap device and back flow device are not supplied as part of the unit These devices are available through your standard plumbing supply house Alternate Bypass If preferred owner installer is...

Страница 5: ...R CITY WATER Easy Series AB Formulator from Global shown above FROM MANIFOLD TO ICE MACHINE TO ESPRESSO BREWER WALL WALL Back Flow Device TO Water Heater TO ICE MACHINE SOFT HARD WATER TO ESPRESSO BRE...

Страница 6: ...In Casters D AB Formula Caps with Siphon Tubes E 3 8 Blue Tubing F Elbow Connectors G Espresso Connectors 35 ft of 3 8 Tubing provided D J AB Formulator on Metro Rack K Tube Cutter J C E F H I K List...

Страница 7: ...e ties under two bars on the metro rack around the manifold and through the zip tie locking device The manifold can be attached on the left or the right of the system Use tube cutter to trim the exces...

Страница 8: ...g up the notches 7 Now the system is ready for you to turn on the water to the system Open the city feed to system Double check the A B Formula box connections It will take about 20 30 minutes to fill...

Страница 9: ...up System pressure gauge should go up to 60 psi 12 Verify that there are no leaks Filter change is now complete Emergency Bypass In some emergency situations it will be necessary to put the unit into...

Страница 10: ...Turn yellow lever on top not front of Easy System from normal mode to test mode Note water should immediately start to flow out of black 1 4 tube 4 Place the black tube into the 500 ml graduated cyli...

Страница 11: ...o bypass Emergency situations which require putting the bypass handle into the bypass position turning the bypass handle yellow handle to point towards the word bypass are 1 System pressure gauge read...

Страница 12: ...brew coffee during troubleshooting procedures equipment damage may result Y STEP INSTRUCTIONS Step 1 Step 1 Check the system pressure gauge reading If the pressure reading is normal 35 60 psi then the...

Страница 13: ...System Service Log Record DATE PRE FILTER POST FILTER MEMBRANE CLEANING OTHER TECH NAME START UP START UP TDS INCOMING DATE BY PPM PSI Easy AB Formulator Unit Guide Page 13...

Страница 14: ...s recommendations and applicable state and local codes The Global Customized Water Limited Warranty extends to the original purchaser of the system This warranty covers all parts and factory labor nee...

Страница 15: ...accompanies the system Neglect improper maintenance abuse or unapproved modifications may invalidate the Warranty Should your unit develop a defect or otherwise fail to perform in accordance with this...

Отзывы: