GBC Fusion Punch II with Offset and Bypass Stacker
Floor Load
Device
Uniform load
Point load
Fusion Punch II
51.67 lbs / sq.ft. (253 kg / sq. m)
Casters A:
108.5 lbs / sq.in. (7.63 kg / sq. cm)
Casters B:
201.5 lbs / sq.in. (14.2 kg / sq. cm)
Bypass Stacker
53 lbs / sq.ft. (259 kg / sq. m)
Casters:
80 lbs / sq.in. (5.62 kg / sq. cm)
Offset Stacker
45 lbs / sq.ft. (219 kg / sq. m)
Casters:
67.5 lbs / sq.in. (4.75 kg / sq. cm)
Fusion Punch II
Bypass
Stacker
Offset
Stacker
Caster
Feet
Note: The leveling feet on the Fusion Punch II and the Bypass /
Offset Stackers are only used to lock the solution in place after
installation. The casters will carry the entire load at all times and
therefore there are is no point load for the leveling feet.
Floor Level
X1
X2
Fusion Punch II
Offset
Stacker
Bypass
Stacker
Configuration
Measurement
Specification
X1
9 ft (2.74 m)
2 “ (50.8 mm) over entire length, or 0.22 in./ ft (15.2 mm / m)
X2
6.75 ft (2.1 m)
1.48 “ (37.6 mm) over entire length, or 0.22 in./ ft (15.2 mm / m)
Note: The floor level is based on a printer paper exit height
above the floor of 34” (860 mm).
1-5