02_340_001_AJ_BE(Rev 11/05/11)
(from French version : 02_340_000_AJ_BE (Rev 11/05/11)
Portable Inspectra Laser
©Copyright Gazomat
37/48
7
View of the hydrophobic filter.
8
Clean the filter enclosure with a dry cloth and clean the
cap.
9
The hydrophobic filter must necessarily be replaced if it
is polluted by water; replace the o-ring seal if needed.
Place the seal on the filter, fit the filter and seal in the
housing and screw back the cap that shuts the housing of
the hydrophobic filter.
10
Tighten the cap of the hydrophobic filter housing
by
hand, without tightening it
.
11
Switch on the device and then
insert the
plugged quick coupler.
12
Use the pin wrench to tighten the cap till the pump stops
completely.
Do not tighten any more: that could
damage the seal of the cap.
Replacing the hydrophobic filter in the device