02_340_001_AJ_BE(Rev 11/05/11)
(from French version : 02_340_000_AJ_BE (Rev 11/05/11)
Portable Inspectra Laser
©Copyright Gazomat
33/48
8.1.2 G
EIGER ALARM
The Geiger alarm is a discontinuous alarm, where the frequency is proportional to the
measured concentration.
8.2 E
XPLOSIVE RISK ALARM
The explosive risk alarm is a continuous alarm, which is set off when the measured
concentration is greater than or equal to the LEL of methane gas (44000 ppm, i.e. 4.4% gas).
The alarm is not configurable. For safety reasons, the user cannot mute or disable this alarm.
8.3 M
ALFUNCTIONING OF THE MEASURING ELEMENT
Some sensor defects are identified and displayed on the LCD matrix:
ERR00X with X = 1 - 7.
The error display is accompanied by an audio signal: two beeps at a frequency that increases
gradually.
The sound alarm can be cleared by pressing keypad key 5.
8.4 10,000-
PPM MEASURING RANGE OVERRUN
With the 10,000-ppm version of the Inspectra
Laser detector, the maximum displayed value
is 12,000 ppm. Beyond that concentration value, the measuring range is exceeded, leading to
the following:
- the display remains blocked on 12,000 ppm and the value flashes.
- the sound alarm is activated.
- the limit alarm LED is activated at the same time with the explosive risk alarm
LED.