background image

10

Pro

 line

Pro

 line

9.2  

Error or warning indications

Status LED message

Status luminaire

Description

Action / Solution

Too low voltage

Input voltage is too low

Check mains voltage

Too low voltage occured 

in past

See above, reset

Too high voltage

Input voltage is too high

Check input voltage, check wiring 

and connection, check neutral in 

3 phase systems

Too high voltage occured 

in past

See above, reset

Too high temperature

Electronics temperature is too 

high (max. 115 °Celsius )

Disconnect from mains. Check 

installation, clean ballast, check 

environment temperature (max 

35 °Celsius). Make sure the 

luminaire is not heated by HPS 

lamp light. Wait until the lamp is 

cooled down, then reconnect to 

the mains.

Too high temperature 

occured in past

See above, reset

No signal from 

controller

Luminaire is connected to the 

mains and set to EXT but there is 

no signal on the control input.

If a controller is connected, 

search for loose connections, 

defect contacts or short-circuits.

10  

Inspection, maintenance and repair

 

6

Warning! 

Disconnect the product from mains before performing any maintenance or repairs.

 

6

Warning!

 Do not connect or disconnect the Wieland RST20i3 plug under load.

 

6

Warning!

 Do not open or disassemble the luminaire, it contains no servicable parts inside. Opening the luminaire can 

be dangerous and will void the warranty.

 

6

Warning!

 Always allow for a cool down period of at least 30 minutes before touching the lamp or reflector.

 

1

Caution!

 Do not clean the luminaire with detergents, abrasives or other agressive substances.

 

1

Caution!

 Do not touch the inside of the reflector during installation and do not use water, abrasives or detergents to 

clean it. This will damage the reflective surface.

 

2

Note:

 Gavita recommends to measure the lamp and reflector for aging every year. Replace the lamp and/or reflector 

when they are aged.

• 

Regularly check the luminaire for dust or dirt buildup. Clean if necessary. Contamination may couse overheating and 
decreased performance.

 

− Clean the inside of the reflector only with a soft, dry cloth;

 

− Clean the electronic ballast and the outside of the luminaire using a dry or damp cloth.

• 

Check the lamp monthly for discolorations or black markings. Always replace a damaged lamp.

 

1

Note:

 Before initial use, the lamp could have black markings. This will disappear when the lamp runs on full power. If 

not, replace the lamp.

• 

Regularly check the wiring of the product to ensure it is undamaged.

10.1  

How to disconnect the Wieland RST20i3 plug

 

6

Warning!

 Do not connect or disconnect the Wieland RST20i3 plug under 

load.

1.  Switch off mains power.
2.  Press the pin on the Wieland RST20i3 male connection inwards and pull the 

Wieland RST20i3 female connection from the luminaire (18).

B

B2

1

18 

Содержание Pro 1000e

Страница 1: ...possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes tot the conservation of natural resources Therefore please do not dispose of your old electronics and electrical appliances via household waste A B This symbol indicates the minimum distance B between the luminaire A and the lit surf...

Страница 2: ...on Gavita Pro 1000e 380 400V DE EU Product weight 3 8 kg Dimensions L W H 56 5 x 24 5 x 19 5 cm Temperature case 70 Celsius Temperature ambient 0 35 Celsius Input voltage 380 400 V AC 10 8 Input current typical 2 8 2 7 Amps Input power typical 1050 Watt Power factor 0 98 Total Harmonic Distortion 10 Frequency 50 60 Hz Certification EN 60598 1 EN 55015 2015 Insulation Class 1 requires an earth conn...

Страница 3: ... no servicable parts inside Opening the luminaire can be dangerous and will void the warranty This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0 45 30 MHz Do not use the luminaire when either its lamp or its power cord are damaged Replace the pow...

Страница 4: ...lectronic ballast 2 Lamp bracket 3 Lever to unlatch reflector 4 Lamp sockets 5 Reflector Gavita HR96 DE 6 Mounting points The reflector is delivery dependent it may differ from the image B Gavita Pro Plus 1000W EL DE C Interconnect cable 6PC6 modular jack delivered separately D Dummy E Wieland RST20i3 female connector with open end cable delivered separately A6 A1 A6 B A3 A5 A4 A2 C C C D C E 1 Ga...

Страница 5: ...ixture see paragraph 10 2 4 If not pre installed screw the mounting point into the luminaire 5 7 2 Installing the luminaire 1 Mount the suspension bracket according to the light distribution plan 2 Hang the fixture by its two mounting points onto the suspension bracket 4 The two mounting points are spaced 30 32 cm apart 1 Caution Always hang the fixture horizontally If necessary adjustments can be...

Страница 6: ...ontroller to connect the controller input port on the first luminaire 10A 3 Remove the dummy from the input port on the second luminaire 4 Use a grey 6P6C modular jack interconnect cable item C with integrated ferrite cores to connect the output port of the first luminaire to the input port of the second luminaire 10B The indicator light will blink when the connection is successful 5 Repeat these ...

Страница 7: ...f a splitter to the inport of the next 11B 8 Use the black secondary channel item comes with controller 10G to connect another 500 luminaires in the same way the luminaires are connected to the primary channel 6 Warning Ensure the power cord and the controller cables do not touch any of the reflectors 6 Warning Distribute number of luminaires evenly over daisy chains 6 Warning Ensure the repeater ...

Страница 8: ...the luminaire 1 Plug the Wieland RST20i3 female connection onto the Wieland RST20i3 male connection on the luminair 12 2 Switch on mains power 6 Warning Do not connect or disconnect the Wieland RST20i3 plug under load To install a new power cord 1 Remove the top part of Wieland RST 20i3 female connector from the bottom part 13 2 Pull the mains cable through the bottom part 14 3 Strip the wiring 15...

Страница 9: ...ED signals are represented by colored dots All operating modes include GREEN All warning codes include RED All history codes except the ignition code include ORANGE WARNINGS and history codes overrule operating mode display 9 1 Status indications Status LED message Status luminaire Description Action Solution No power off The luminaire is not connected to the mains or the power is off Check power ...

Страница 10: ...nside Opening the luminaire can be dangerous and will void the warranty 6 Warning Always allow for a cool down period of at least 30 minutes before touching the lamp or reflector 1 Caution Do not clean the luminaire with detergents abrasives or other agressive substances 1 Caution Do not touch the inside of the reflector during installation and do not use water abrasives or detergents to clean it ...

Страница 11: ... hours whichever one comes first 1 Switch off mains power 2 Hold the lamp with a fabric glove to prevent it from falling Use a protective glove if the lamp is damaged 3 Open the lamp holders by sliding them outwards 19 4 Carefully take the lamp out of the luminaire 20 5 Install the new lamp with the getter near the ballast 21 with the glass vacuum seal pointed downwards Philips lamps or sideways G...

Страница 12: ...The reflector is delivery dependent it may differ from the image 1 Switch off mains power 2 Remove the lamp from the luminaire see paragraph 10 2 3 Support the reflector on the side of the reflector lever to prevent it from falling 23 4 Move the reflector lever up to retract the two pins holding the reflector in place 24 5 Remove the reflector 25 6 Place the new reflector Ensure the reflector leve...

Страница 13: ...erial and workmanship if used under normal operating conditions for a period of three 3 years from the original date of purchase If the product shows any defects within this period and that defect is not due to user error or improper use Gavita International bv shall at its discretion either replace or repair the product using suitable new or reconditioned products or parts For HPS lamps the warra...

Страница 14: ......

Страница 15: ......

Страница 16: ...eg 8 1437 EL Rozenburg NH The Netherlands T 31 0 297 380 450 F 31 0 297 380 451 info gavita com www gavita com Pro line Pro line Manual Gavita Pro 1000e 380 400V Changes reserved Version 21 11 Not for sales or use in the Netherlands ...

Отзывы: