background image

7. 

Installation

   Warning!

 Mounting and installing of the fixture can only be executed by certified 

servicepersonnel, in accordance with the applicable local laws and regulations.

   Warning!

 The fitter is responsible for correct and safe installation.

   Warning!

 Ensure the local cabling can support the voltage and current 

requirements of the fixture.

   Warning!

 Avoid coiled cords and keep mains leads separated. This prevents 

electromagnetic interference.

   Warning!

 Do not disconnect the Wieland RST20i3 plug under load. 

7.1. 

Installation preparations

• 

Switch off mains power.

• 

Read the Gavita light distribution plan.

• 

If not done already, install the lamp in the fixture (see paragraph 10.1).

• 

If not done already, screw the mounting point into the fixture (3). 

7.2. 

Installing the fixture

• 

Mount the suspension bracket* according to the light distribution plan.

• 

Hang the fixture by its two mounting points onto the suspension bracket (4). The 

two mounting points are spaced 30 - 32 cm apart.

   Caution!

 Always hang the fixture horizontally. Adjustments can be made by 

screwing the mounting point in or out.

To install other fixtures, repeat the steps at paragraph 7.1 and 7.2.

* The suspension bracket is delivery dependent, it may differ from the image.

7.3. 

Connecting the fixture to the mains

   Warning!

 Make sure mains power is switched off.

   Warning!

 Always install the lamp before connecting the fixture to the mains.

 Warning!

 Ensure the cord is not coiled and does not touch any hot surfaces. 

 Warning!

 Connect the cables according to local rules and regulations.

   Warning!

 Ensure external switching gear can cope with the inrush current of 

the fixture (see paragraph 3.2). Always use a double throw contactor suitable for 

switching a capacitive load. Never use household timers to switch the fixture! 

• 

Connect the wires of the female Wieland RST20i3 cable with the distribution 

cable of the electrical installation.

   Caution!

 Use a suitable sealed joint to connect the cables.

• 

Cable description: 

Wire

230V

400V

Blue

Neutral

Phase

Brown

Phase

Phase

Green/yellow

Ground ( )

Ground ( )

   Warning!

 Make sure the wires are connected correctly to prevent short-circuit.

• 

Plug the Wieland RST20i3 female connection onto the Wieland RST20i3 male 

connection of the fixture (5). 

• 

Switch on mains power. 

   Warning!

 Do not disconnect the Wieland RST20i3 plug under load. 

B2

B1

3. 

4. 

5. 

B1

B2

B1

B2

600W

0,6 m -

23 5/8 in

Содержание GAN Electronic 600 W 230 V EU

Страница 1: ...or packaging indicates that this product may not be discarded as household waste Dispose of the equipment through a recycling centre that handles electronics and electrical appliances within the EU and in other European countries which use separate collection systems for used electronics and electrical appliances By disposing of the equipment in the proper way you will be helping to prevent possib...

Страница 2: ... condensating Total Harmonic Distortion 10 Frequency 48 63 Hz Certification CE Insulation Class 1 requires an earth connection IP21 Power inlet Wieland RST20i3 IP65 connector Ignition voltage 3 5 kV 3 3 Compatible products and accessories Product name Gavita part number Replacement reflector Ecomax HR96 30 46 02 10 Compatible lamps Gavita Pro 600 W Electronic HPS E40 26 64 40 02 Philips Master Gre...

Страница 3: ...or a cool down period of at least 30 minutes before touching the lamp or reflector Touching the lamp or the reflector when the lamp is lit or immediately afterwards will result in severe burns Never touch the lamp with bare hands as this will cause damage to the lamp Do not use the fixture near flammable explosive or reactive substances The lamp and the reflector of the fixture reach temperatures ...

Страница 4: ... out To install other fixtures repeat the steps at paragraph 7 1 and 7 2 The suspension bracket is delivery dependent it may differ from the image 7 3 Connecting the fixture to the mains Warning Make sure mains power is switched off Warning Always install the lamp before connecting the fixture to the mains Warning Ensure the cord is not coiled and does not touch any hot surfaces Warning Connect th...

Страница 5: ... lamp is working correctly EOL timer expired Maximum number of ignition attempts done without succes or a driver is locked or has failed Reset mains cycle manually Cycle error Maximum number of succesful ignition attempts done lamp stopped for unknown reason Reset mains cycle manually Low mains Mains voltage too low Mains cycle automatically resets Thermal overload Maximum driver temperature excee...

Страница 6: ...ecessary Contamination may couse overheating and decreased performance Clean the inside of the reflector with soapy water but use demineralised water to rinse the reflector Clean the electronic ballast and the outside of the fixture using a dry or damp cloth Check the lamp monthly for discolorations or black markings Always replace a damaged lamp Note Before initial use the lamp could have black m...

Страница 7: ...the new reflector Ensure the reflector lever is in the opened position to allow the reflector to pass Ensure the holes in the reflector are aligned with the pins in the fixture 11 Release the reflector lever so its two pins hold the reflector in place Insert the lamp in the lamp holder see paragraph 10 1 Switch on mains power 11 Storage and disposal Store the fixture in a dry and clean environment...

Страница 8: ...ta Nederland bv Oosteinderweg 127 1432 AH Aalsmeer The Netherlands Tel 31 0 297 380 450 Fax 31 0 297 380 451 E info gavita nl W www gavita nl Manual GAN Electronic 600W DE EU Changes reserved Version 15 05 ...

Отзывы: