background image

1. The product is repaired free of charge within the warranty period if a malfunction occurs 

through normal and proper use in accordance with the instruction manual. 

2. When asking for repairs within the warranty period, please make sure to bring and present the 

product and the warranty to the service provider.

3. If you received the product as a gift or moved overseas and cannot ask the service provider to 

do the repair, please contact GAURA Co., Ltd.

4. Repairs for the following cases will be accepted with a repair charge even if it is within the 

warranty period.

• This warranty guarantees free repairs during the warranty period under the conditions stated in 

the policy. 

• Please note that personal information entered in the warranty (as seen in the customer copy of 

the warranty) may be used for service activities and subsequent safety inspection activities 

within the warranty period.

① 

No warranty presented.

② 

The warranty does not include the date of purchase, name of customer and name of the 

service provider, or if such information has been altered on the warranty.

③ 

Malfunctions or damages caused by misuse and unauthorized repairs and modifications.

④ 

Malfunctions or damages caused during transportation, moving or dropping the product 

etc. after the product is purchased .

⑤ 

Malfunctions or damages caused by external causes such as fires, pollution, abnormal 

voltage, earthquakes, water hazards, lightning and other natural disasters.

⑥ 

Malfunctions and damages caused on vehicles and ships.

⑦ 

Malfunctions or damages caused from the product being used for purposes other than 

personal use (for example, commercial use or purpose).

⑧ 

Replacement of consumable parts.

Free Repair Policy

8

17

18

Product Name

Model Number

Color

Capacity

Operating mode

Number of uses after fully charged

Durable temperature

Rated voltage/current

Weight

Size

Accessories

Material

Hydrogen concentration

Charging time

Power consumption

Power

Rechargeable times  

Usable times

Water quality to use

Portable Hydrogen Water Bottle GAURA walk

Pearl White / G-WW-001, Metallic Black / G-WB-001, Rose Pink / G-WP-001,

Silver Blue / G-WS-001, Champagne Gold / G-WG-001

5 colors (Pearl White, Metallic Black, Rose Pink, Silver Blue, Champagne Gold)

380ml

5 minutes mode, cleaning mode, inhale mode

5 minutes mode : Approx.6 times, cleaning mode : Approx.10 times, 

inhale mode :Approx. 1 time

0-80℃ 

*CAUTION: HANDLE WITH CARE and be careful of burns when using the product with high temperatures

5V/1A

258g

Longest diameter of top(including opening button) 78mm, shortest diameter of top

68mm, longest diameter of bottom 70mm, height 237mm

USB AC/DC Adapter, USB Power Cable, Chlorine Removal Cartridge, 

Inhaler Cap, Inhaler Cannula. Instruction Manual 

PCTG, ABS, Silicon rubber

5 minutes 0.8~1.0 ppm (measured at water temperature 25℃)

Approx.5 hours

6-7.4W

Built-in Lithium Ion Battery 850mAh

Approx.500 times  

5 minutes mode: Approx.3000 times, inhale mode : Approx.500 times

*Usable time will vary depending on battery usage.

Hydrogen water : Drinkable tap water, Mineral water, 

Filtered water, RO (reverse osmosis)

 

water

Hydrogen gas inhalation: Mineral water, Refined water 

7

Water Leakage

• Make sure the cap is tightly closed.

• The button, spring and rubber seals of the cap are consumable parts and not covered by 

warranty (except for initial defects).

• Do not lay the bottle on its side or tilt the body of the bottle sideways while hydrogen water is 

being generated. This may cause water leakage.

• If you wish to suspend the generation of hydrogen water in the middle of the process, wait at 

least 5 seconds from the time hydrogen generation was started, and then press the power 

switch again.

• It is not possible to charge the bottle while generating hydrogen water. Disconnect the USB 

AC/DC adapter from the main body. (If water enters from the USB port, this causes 

malfunctions. Therefore, make sure to close the lid of the USB port when using or cleaning the 

bottle).

• If LED lights in the bottle turn red, this means there is not much battery left. Once the battery is 

exhausted (zero charge left), you cannot use the product so charge the bottle before use.

• Immediately after the generation of hydrogen water, the air pressure inside the bottle increases, 

so when you open the top of the cap, you may hear a "popping" sound.

• Calcium etc. (white solids) in drinking water may build up in the hydrogen generator. Run the 

cleaning mode or use commercially available citric acid solution and leave to clean.

*  Refer to 

How to Care for the Product

Precautions for Use

■ 

Specifications

Содержание G-WB-001

Страница 1: ......

Страница 2: ...GAURA walk 80 USB AC DC 100 240V 300 3 6 1 USB AC DC USB USB USB AC DC USB AC DC 1 2...

Страница 3: ...1 2 3 5 6 7 8 4 6 LED 1 5 LED 1 LED LED RO 10 USB AC DC LED USB AC DC 9 9 USB USB USB AC DC USB USB LED LED LED 2 3 4 5 USB USB AC DC USB 9 LED LED USB 5 3 4...

Страница 4: ...2 2 1 3 30 LED 1 LED LED LED 5 LED 3 LED 100ml 10 5g 100ml 2 3 1 0 LED USB AC DC USB AC DC USB 6 5 USB 5 6 9 9...

Страница 5: ...AC DC USB USB LED 0 7 V A GAURA walk G WW 001 G WB 001 G WP 001 G WS 001 G WG 001 5 380ml 5 5 6 10 1 0 80 5V 1A 258g 78mm 68mm 70mm 237mm USB AC DC USB PCTG ABS 5 0 8 1 0ppm 25 5 6 7 4W 850mAh 500 5...

Страница 6: ...Contents Safety Precautions Names of Parts How to Charge Preparations Before Use How to Use How to Care for the Product Precautions for Use Free Repair Policy Portable Hydrogen Water Bottle Instructi...

Страница 7: ...cause fires short circuits and electric shock Do not put the USB AC DC adapter in water or spray water on it This may cause short circuits and electric shock Stop use immediately if you do not feel we...

Страница 8: ...d Generating Hydrogen Water 4 5 9 Image of how to attach chlorine removal cartridge Attach by twisting clockwise Charge the product with the USB AC DC adapter included in the package After full charge...

Страница 9: ...cid solution is recommended Pour 100ml or more of citric acid solution into the bottle and leave for about 10 hours to make citric acid solution dissolve 5 g of citric acid in 100 ml of lukewarm water...

Страница 10: ...te Metallic Black Rose Pink Silver Blue Champagne Gold 380ml 5 minutes mode cleaning mode inhale mode 5 minutes mode Approx 6 times cleaning mode Approx 10 times inhale mode Approx 1 time 0 80 CAUTION...

Страница 11: ...ty Product Name Model Number Serial Number Customer Information Service Provider Warranty Period Importer Portable Hydrogen Water Bottle GAURA walk G WW 001 G WB 001 G WP 001 G WS 001 G WG 001 Name Ad...

Страница 12: ...GAURAwalk 80 C USB AC DC 100 240V 300 3 6 1 USB AC DC USB USB USB USB USB AC USB AC DC 21 22...

Страница 13: ...1 2 3 5 6 7 8 4 LED 5 LED 1 LED 7 LED 10 USB AC DC LED USB AC DC 90 90 USB 1 USB 2 USB AC DC 3 USB USB LED LED LED 2 3 4 5 USB 9 LED LED USB 5 23 24 USB AC DC USB 6...

Страница 14: ...3 30 LED 1 LED 7 LED LED 5 LED 3 LED 100ml 10 5 100 2 3 0 LED USB AC DC USB USB AC DC 6 5 USB 25 26 90 9...

Страница 15: ...AC DC USB USB LED 0 0 7 V A GAURAwalk G WW 001 G WB 001 G WP 001 G WS 001 G WG 001 5 380ml 5 5 6 10 1 0 80 5V 1A 258g 78mm 68mm 70mm 237mm USB AC DC USB PCTG ABS 5 0 8 1 0ppm 25 5 6 7 4W 850mAh 500 5...

Страница 16: ...gaura 150 0011 2 26 16 HANA 4F Tel 81 3 6805 0207 E mail info gaura co jp 2020 7 1 29 30 GAURA walk G WW 001 G WB 001 G WP 001 G WS 001 G WG 001...

Отзывы: