background image

 

12 

 

number,  press  "  Call2"  can 

dial  the  third  number.  if  a 

new number is coming, you 

can  listen  by  hang  up 

button,    hang  down  button 

for close 

Monitor Function 

Send : 555+Password 

Eg: 5550000 

After  the  unit  receive  this 

command, the unit will call 

the sender   

SOS Alarm 

Send SOS Alarm Command : 720 

Eg

#720#3# Password ## 

This  command  is  mean  that  when  you  press  the  SOS 

Button,  the  unit  will  call  to  the  center  number  and  send 

SOS Alarm message to the center number   

The  default  state  is  close 

this funciton ,so if you don't 

set  720  command,  the  unit 

will  not  take  alarm  even 

press the SOS Button   

Geo Fence Function 

  Send 750 Command

 

#750#radiusmeters(5digits)#interval(minutes)#passwor

d## 

Choose the current point to the basic point. 

  #750#100#1#0000# 

   

 

 

 

 

(2)#751#500#5#2234.5848N#11354.028#0000## 

 

This  command  is  mean   

that the unit will get the gps 

satellite and get the correct, 

then  the  first  position  will 

be  the  basic  point,after 

configuration,the  unit  will 

check  whether  the  unit  is 

over  the  area  every  one 

minute  (the  time  you  can 

set it ) , if over the area, the 

unit  will  take  alarm  to  the 

sender 

(2)This  command  is  that 

get  the  single  latitude  and 

longitude  to  set  the  geo 

fence, 

put 

2234.5848N,11354.028E be 

the  origin  point,  and  the 

radius  is  500meters  for  the 

area . 

Cancel  or  Check  the 

Geo Fence Function 

1

#760# Password # 

 

 

 

2

#752# Password # 

1

This  command  can 

cancel 

the 

geo 

fence 

function  that  you  already 

set it ago.   

2

This  command  can 

check  the  information  of 

geo fence   

Change  the  password  of 

Unit   

#770#1111# Password ## 

Change 

0000(initial 

password)  to  1111  (new 

password) 

Other Function 

1

#901## 

2

#902## 

1    Read the User data 

2

Read 

the 

GPRS 

Содержание PT350

Страница 1: ...racker User Manual Edition 1 0 Copyright Feb 15 2009 GATOR GROUP CO LTD All rights reserved LA Brand http www gatorcn com China Printing WEB http www gatorcn com EMAIL vip12 gatorcn com Tel 86 755 230...

Страница 2: ...responding to and Operation Method of Basic Functions 5 1 Location Inquiry 5 1 SMS Inquiry 5 2 Setup of Center Number 6 3 Bi directional Call Function 6 5 Monitoring Function 6 6 Regular Upload Interv...

Страница 3: ...ose for the actual product the latter will prevail 3 The defaulted password of this product is 0000 Chapter II About the Device PT350 as a personal remote positioning device made up of GPS module and...

Страница 4: ...Technical Specifications GSM module GSM850 1900Hz or GSM900 1800MHz two combinations GPS chip Latest GPS sensitivity 159dBm GPS center frequency L1 1575 42MHz GPS positioning accuracy 5 25m GSM posit...

Страница 5: ...USB charging cable For the first charge in order to bring the performance of the battery into full play charge it above 12h Indicator of charging Red being charged Green charging completed III Instal...

Страница 6: ...function to be opened in real time Chapter IV Commands Corresponding to and Operation Method of Basic Functions 1 Location Inquiry 1 SMS Inquiry Create 666 password command defaulted password as 0000...

Страница 7: ...After the setup is successful press the CALL 1 button then the terminal will automatically dia the first phone number Press the CALL 2 button then the terminal will automatically dial the second phon...

Страница 8: ...umber after successful sending the mobile phone with such setup will receive one piece of config ok response information as shown in the following figure Send command to the terminal The terminal will...

Страница 9: ...Example 801 13900139000 0000 Notes After executing this command the user name of the terminal on GPRS mode is required to be set up according to actual demand After the setup is successful the termina...

Страница 10: ...messages to the user according to the alarming setup For example 740 0000 After the fence is set the terminal will alarm in the case where it is moved about 3 5km out of the fence 3 Fence Reading Fun...

Страница 11: ...to the server as the configuration way Point to Point Function1 Single Position 666 Password The unit will send the latitude and longitude information to the sender after send 666 Password in 700 Mod...

Страница 12: ...rd The parameter 20 indicates getting one point every 20s after getting points accumulatively for 4 times upload one piece of positioning information with the upload interval as 20 4 80s When you set...

Страница 13: ...asic point 750 100 1 0000 2 751 500 5 2234 5848N 11354 028 0000 This command is mean that the unit will get the gps satellite and get the correct then the first position will be the basic point after...

Страница 14: ...GPRS network 3 Make sure that the SIM card has sufficient balance in order to avoid inconvenience in use 4 This device will not be able to work in case of power off and out of the service area even if...

Отзывы: