7
SMS format: 5550000
Remarks: 0000 is the initial default password and the actual use s subject to the actual password.
6. Regular Upload Interval Setup
The defaulted factory upload interval of this device is 2 minutes for getting the point and 10 minutes for
uploading one piece of positioning information. The user may change such parameter according to actual
demand.
Command format: # command number 730# Sampling interval # Pieces of uploads # User password ##
For example: #730#20#4#0000##
Note: The parameter “20” indicates getting one point every 20s; after getting points accumulatively for 4
times, upload one piece of positioning information with the upload interval as 20*4=80s. The user may change
this parameter as the case may be.
7. Function of Changing Password
Send the SMS
“#770# User new password # User old password ##”
by mobile phone to the terminal
number, after successful sending, the mobile phone with such setup will receive one piece of config ok
response information, as shown in the following figure:
Send command to the terminal The terminal will return confirmation message to the mobile phone
8. Low-Voltage Alarming Function
If the terminal of the ward has a very low power and needs to be powered off, the terminal of the ward will
automatically upload one piece of low-voltage alarming command to the monitoring center number.
9. Set APN Command
Create the SMS “802#APN letters or digits, 4-20 bits # Log user name letters or digits 4-20 bits in #
Log password letter or digits 4-20 bits in # terminal password 4 bits ##” and send it to the terminal; after
executing this command, the terminal will automatically restart and connect to
GPRS with APN set.
Command example 1: #802#cmnet###0000##
Command example 2: #802#CCDLEN#QIUXIA.21#RX0000#0000##
After this command is executed, APN will be CCDLEN; the login user name is QIUXIA.21 and login
password is RX0000.
Note: The default APN of this product is CMNET.