background image

Instructions for SW200DC

www.gatexpertstore.com

1

Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling
and using it. Please do not leave out the manual if you send this product to a third party.

1. Safety Instruction

Please read this manual carefully before installation, in which involves with important
information about installation

using

maintenance and safety.

Any undefined operations under this manual is not allowed, incorrect using may
damage the product even causing the injuries or property losses.

To consider the possible danger during the installation or using process of swing gate
operator, installation must strictly comply with the construction standard and electrical
operating procedure.

Before installation, please make sure that the power voltage being used matches with
the supply voltage of this product. Please check if the leakage protection switch is
installed and the grounding system is correct.

Please check if additional equipment or materials are required to meet the specific
requirements.

The disposal of packaging material must be complying with the local regulation.

Please do not change any parts except for those defined under this manual. Any
undefined changes may cause the malfunction. Any damages to the product arising
therefrom shall be beyond the liability of the company.

Please do not leak water or any liquid into the controller or any other open devices.
Please disconnect the power immediately if any mentioned cases happened.

Please keep this product away from heat and open fire. Or it may damage the
components; cause the failure or other hazards.

Please make sure there is no vehicles

passengers and objects passing through while

the swing gate is moving.

Anti-clip equipment like infrared protection switch must be installed to avoid injuries to
person and property losses. The company shall not be liable for any damage or
accident arising therefrom.

The installation

using and maintenance of this product must be carried out by

professionals.

Children are not allowed be touch the control devices or remote transmitters.

A warning sign must be placed somewhere on the swing gate according to the
national standard.

Please keep this instruction properly for future reference.

Содержание SW200DC

Страница 1: ...1 Swing Gate Opener User Manual SW200DC Website www gatexpertstore com E mail sales gatexpertstore com...

Страница 2: ...eplace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information in th...

Страница 3: ...meet the specific requirements The disposal of packaging material must be complying with the local regulation Please do not change any parts except for those defined under this manual Any undefined ch...

Страница 4: ...rd No Picture Name Quantity 1 Main machine 2 2 Control box 1 3 Manual release key 2 4 Remote control 2 5 Wall bracket 4 6 Front mounting bracket 2 7 Connecting bracket 2 8 Screw M8X25 4 9 Mounting scr...

Страница 5: ...rs and wall Please prepare the these installation accessories according to actual site situation 3 Technical Parameters Model SW200DC Power supply 220V 50Hz 110V 60Hz Motor power 30W Gate moving speed...

Страница 6: ...orter than 2m The drive mode adopts planetary transmission to combine with the screw rod transmission This gate opener must be installed inside the enclosure or yard for protection 5 Tools Needed for...

Страница 7: ...y 2 1 5mm 15m 3 Cable of infrared sensor 2 0 5mm 10m 4 Cable of alarm lamp 2 0 5mm 10m 5 Cable of electric lock 2 0 5mm 10m 6 Extension cable of storage battery 2 1 5mm 10m 7 Cable of solar power 2 1...

Страница 8: ...has interference after the gate completely open please install a gate safety stopper prepare by user to prevent injury to person or damage to property A B 100mm 120 mm 140 mm 160 mm 180 mm 200 mm 100...

Страница 9: ...111 5 108 5 106 5 105 103 100 5 140mm 118 5 115 112 5 106 96 5 160mm 121 110 101 5 93 5 180mm 106 98 5 92 200mm 96 5 90 5 Note If the interval between the gate and the wall is too small or it has int...

Страница 10: ...d to consider the distance between the two swings c The recommended mounting height of the 2 main machines is around 300 800mm above the ground and make sure there are reliable fixed points for mounti...

Страница 11: ...ll brackets please refer to Figure 5 Figure 5 B The connecting bracket and the wall bracket can be connected according to different conditions please refer to figure 6 Figure 6 C Before the installati...

Страница 12: ...ackets by screw and nut as shown in Figure 8 M8 45 M8 Figure 8 E As shown in figure 9 below connect wall bracket with wall according to marked position Then connect main machine with wall bracket by s...

Страница 13: ...Instructions for SW200DC www gatexpertstore com 11 M8 Figure 9 8 3 Dimension of Control Box 250mm 170mm 78 75mm Figure 10 Front mounting bracket Self locking nut Mouting screw short...

Страница 14: ...sition as shown in figure 2 Before installing the main machine please make sure the main machine and components are in good mechanical performance and the gate can be manually operated flexibly One co...

Страница 15: ...Instructions for SW200DC www gatexpertstore com 13 9 Wiring and Debugging 9 1 Wiring Instructions Figure 11...

Страница 16: ...Lock Output 10 BLK Alarm Lamp Output Note pay attention to the negative and positive 11 24V 24V Output Positive 12 12V 12V Output Positive No output under dormant state 13 EM1 Motor1 Hall Sensor Powe...

Страница 17: ...Instructions for SW200DC www gatexpertstore com 15 Photo Seneor Wiring Instructions Figure 13 WIFI Module Wiring Instructions Figure 14...

Страница 18: ...SU After this step the gate will firstly run towards the closing direction and stop and then the gate will automatically open When the two swing gates are fully open the gates will automatically clos...

Страница 19: ...lockwise to slow down The trimmer can be adjusted to change the opening and closing travel time This adjustment must be finished before travel setting Figure 15 9 6 Learning Remote Control Delete Remo...

Страница 20: ...tings 9 7 1 Base Menu Press PROG to enter into base menu Digital screen shows NE select other functions of this menu by and buttons Press SET to confirm or to enter into sub menu To exit menu press PR...

Страница 21: ...To switch single gate mode dual gates mode Single gate mode Open gate time interval 3 seconds default 15 seconds default Automati c closing time Remote control mode Dual gates single channel mode Four...

Страница 22: ...c closing function will be canceled Community mode with automatic closing function When the gate opens any gate command will not be responded until it closes automatically If user sends gate command d...

Страница 23: ...keys o p s Automatic closing with Single Gate Dual Gates Switch Dual gates mode default Single gate mode Dual gates mode Open Gate Time Interval 00 10 Open gate time interval is 0 10 seconds default...

Страница 24: ...rol board will automatically enter the low consumption mode after 1 minute Low consumption mode off Low consumption mode on 9 7 3 Advanced Menu Instruction Long press PROG 2 seconds to enter into adva...

Страница 25: ...off Electric lock normally on Alarm lamp Electric lock Alarm lamp normally flash Gate opener secection Stop block Hall sensor Limit switch mode Alarm lamp normally on SW400DC SW300DC Electric lock nor...

Страница 26: ...r SW200DC www gatexpertstore com 24 SW200DC Direction of the door Gate Opens Inwards Gate Opens Outwards Buzzer The buzzer is off The buzzer is on Factory initialization uninitialize Complete initiali...

Страница 27: ...under the resistance limit the farther the deceleration distance of the door And in the Hall limit the shorter the time the shorter the door travel Photo Sensor N C photo sensor normally is on Defaul...

Страница 28: ...ult Alarm lamp normally flashes 24V power supply Alarm lamp normally is on 24V power supply Limit Switch Mode Stop block Default Hall sensor Stop block Gate Opener Secection SW400DC SW300DC Default SW...

Страница 29: ...erve the right to change the instruction without prior notice 10 2 Error Message Errors that may occur when the door is operating properly Wrong Indication Cause of Error Solution Door 1 Obstructed in...

Страница 30: ...ensitivity appropriately 3 Increase deceleration distance appropriately Door 2 is closing with difficulty 1 Check whether there are obstacles when door 2 is closed 2 Adjust resistance sensitivity appr...

Страница 31: ...ng position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not...

Отзывы: