background image

Instructions for PY300DC

www.gatexpertstore.com

15

Setting the Open and Closed Position

1. Press and hold SET until digital dispalys “1”.
2. Press and hold OPEN until gate opens to a proper open position(The open position will

be determined by customer themselves. Note: Press OPEN, the gate will open, if it’s not
opening, please change the motor wire “T1” and “T2”)

3. Press SET to confirm the open position, the digital will dispaly “2”.
4. Press and hold CLOSE until gate closes to a proper closed position.(The closed position

will be determined by customer themselves.)

5. Press SET to confirm the closed position.
6. After these steps, the gate will automatically run a complete opening and closing cycle.

Figure 19

Adjusting the Auto-close Time:

1. Press and hold OPEN until digital display “

”.

2. Press OPEN to add the time for Auto-close, press CLOSE to reduce the time.
3. If the time setting is 0, there will be no Auto-close function.
4. Press SET to confirm.
5. The number increase by 1, the time will add by 10 seconds.

Note: The Auto-close function will work only after the sliding gate runs to open
position.

Содержание PY300DC

Страница 1: ...Sliding Gate Opener User Manual PY300DC Website www gatexpertstore com E mail sales gatexpertstore com...

Страница 2: ...tion When mounting and positioning this product please ensure the power cable is unplugged The motor cover will need to be removed to mount the motor to the mounting plate or directly to the concrete...

Страница 3: ...eplace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information in th...

Страница 4: ...moving Installing Motor Cover 6 Step 4 Motor Pad Footing 7 Step 5 Fitting Mounting Plate and Motor 7 Step 6 Gear Rack Motor Alignment 9 Step 7 Powering on 11 Step 8 Testing Travel and Limit Stops 11 P...

Страница 5: ...site direction This will give you an understanding of the way in which the opener will move the gate Figure 2 Note Ensure that the gate opener is unplugged before proceeding with installation Please k...

Страница 6: ...injury to person or damage to property Instruct all users about the control systems provided and the manual opening operation in case of emergency Ensure that the power cable is connected to a RCD pro...

Страница 7: ...l Release Keys 2 3 Remote Controls 2 4 Accessories Box 1 5 Manual Release Bar 1 6 Anchor Bolts M8 4 6 1 Nuts M8 8 6 2 Flat Washers 8 8 6 3 Spring Washers 8 8 Note Extra flat washers and spring washers...

Страница 8: ...g of the door through an external push button Alarm lamp Alerts people near the gate and users that the gate is in operation Technical Parameters Model PY300DC Power Supply 110VAC 60Hz 220VAC 50Hz Mot...

Страница 9: ...nly be completed by a licensed electrician Tools Required Tape measure Level 12mm concrete drill and hammer when uses expansion screws Phillips head screwdriver Straight screwdriver Example Sliding Ga...

Страница 10: ...able the motor get into manual mode and check that the motor output gear rotates freely by hand Figure 6 Figure 6 Step 3 Removing Installing Motor Cover Unscrew the two cover screws located at each si...

Страница 11: ...e is level and parallel to the driveway Mounting Plate Dimensions Figure 8 Step 5 Fitting Mounting Plate and Motor Without Mounting Plate Pre embed the anchor bolts according to holes in motor base be...

Страница 12: ...ht of the motor Figure 10 With Mounting Plate Pre embed the anchor bolts as per 10 holes in Figure 8 before concreting after hardening place the mounting plate fit and tighten anchor bolts as per figu...

Страница 13: ...utput gear has a minimum clearance of 1 2mm along the entire length of gear rack fitted to the gate as per Figure 14 Ensure output gear and gear rack are correctly aligned Under no circumstances shoul...

Страница 14: ...Instructions for PY300DC www gatexpertstore com 10 Figure 14 Figure 15 Open Position Output Gear Mounting Plate...

Страница 15: ...ding gate is in the middle position Please refer to control board setting page 15 to set the open limit stop position and closed limit stop position The ideal closed final position for the gate frame...

Страница 16: ...minal J4 Terminal Transformer Secondary AC24V 3 3A Programming and Wiring Any works to the 110V 220V AC must only be performed by a licensed electrician Ensure power is off before any modifications ar...

Страница 17: ...MP Alarm Lamp 24VDC Terminal LAMP Alarm Lamp 24VDC J3 Terminal Terminal GND Common Terminal for Photocell Terminal PE Photocell Input N C Terminal 24 Additional Accessories 24VDC Additional accessorie...

Страница 18: ...inal that you are looking to connect to Refer to Page 12 Tighten with a screwdriver to secure the wire in place Wiring to the Terminal Wiring to the Transformer Figure 18 Using a screwdriver to loosen...

Страница 19: ...LOSE until gate closes to a proper closed position The closed position will be determined by customer themselves 5 Press SET to confirm the closed position 6 After these steps the gate will automatica...

Страница 20: ...lowest level 3 Press SET to confirm the setting Note The sensivity should be set according to the gate weight to ensure the reverse function is workable or it may have potential safety concerns Figure...

Страница 21: ...red Photocell is blocked the gate will stop and reverse immediately to protect user and property security To install photocells connect wiring as per Figure 23 The distance between photocell receiver...

Страница 22: ...gate will open 1m wide to allow pedestrian access Single Button Mode Remote Control Figure 24 Remote Control Learning 1 Press CODE button once the red light on digital tube will be on 2 Press the butt...

Страница 23: ...9 Clearing Remote Controls To delete all paired remote controls press and hold the button CODE till digital displays C all previously paired remote controls will be deleted Figure 26 Connecting Storag...

Страница 24: ...ar charger charger Storage Storage battery battery Control Control board board Figure 28 Maintenance The gate should be checked every month to make sure it operates normally For the sake of safety eac...

Страница 25: ...ared port and GND short circuit if connect infrared sensor please make sure the wiring is correct and the photocell is N C 3 Make sure that the photocell mounting position can be mutually aligned 4 Re...

Страница 26: ...Instructions for PY300DC www gatexpertstore com 22 Drawing and Measurements Figure 29...

Отзывы: