Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
Terminal DC Motor: Black connect to “T1”, red connect to “T2”, if the running
direction is opposite, please exchange “T1” and “T2”.
J4 Terminal:
Terminal LAMP+:
Alarm Lamp +24VDC
Terminal LAMP-:
Alarm Lamp -24VDC
J3 Terminal:
Terminal GND:
Common Terminal for Photocell
Terminal PE:
Photocell Input (N.C.).
Te24:
Additional Acces24VDC
Additional accessories sold separately.
J2 Terminal:
Terminal OSC:
Single Cycle for External Push Button
(open/stop/close)
Terminal COM:
Common Terminal for External Push Button.
Terminal OPEN:
External Open Push Button Switch.
Terminal STOP:
External Stop Push Button Switch.
Terminal CLOSE:
External Close Push Button Switch.