Instructions for INDUS-E SERIES Industrial Door Operator
www.gatexpertstore.com
15
CLOSE
STOP
OPEN
O N
1 2 3 4 5
Working Mode Setting
After these 2 steps, please check if the door running condition is to your
standard, if it’s good, you don’t have to do any other settings, the door will work
properly. If it’s not good, you should adjust the relative parameters.
Note:
1) Please adjust the door operator with the buttons on the control unit.
2) After adjustment, please make some trial running first, make sure
everything is correct, fit the control unit on a post that can be observed by you
and should be 1.4 high from the ground to keep it away from Children.
DIP Switch Setting:
ON(Up Position); OFF(Down Position)
No.1: ON-Mechanical Limit Switch; OFF-Electronic Limit switch
No.2: No function
No.3: No function
No.4: ON-Remote Control in Single Button Mode;
OFF-Remote Control in Three Buttons Mode;
No.5: ON-Enable Phase Sequence Detection;
OFF-Disable Phase Sequence Detection
Press and hold “-” for 4 seconds, you can
select manual control or automatic control
mode.
1. Automatic(A): Press “OPEN”, the door
will run to the open limit switch position,
after
waiting
for
the
programmed
auto-close time, it’ll automatically close to
the closed limit switch position.
2. Manual(H): Press “OPEN”, the door will
run to the open limit switch position, press
“CLOSE” the door will run to the closed
limit switch position.