Instructions for INDUS-E SERIES Industrial Door Operator
www.gatexpertstore.com
19
Small door interlock
Small door
C
O
M
S
ig
na
l
Relay terminal
C
O
M
S
ig
na
l
External
accessory
C
O
M
P
ow
er
ne
ga
tiv
e
P
ow
er
po
siti
ve
Loop detector
S
ig
na
l
Loop detector
Safety aibag
Safety aibag
C
O
M
P
ow
er
ne
ga
tiv
e
P
ow
er
po
siti
ve
S
ig
na
l
4. Safety photocell terminal: terminal type is NO, if you need NC type, please modify
the setting of “P2-F4” to be “1”. The valid height of photocell can be adjusted under
“P3-F6”.
5. Safety airbag terminal: There are 2 signal types of safety airbag: level signal and
pulse signal, factory default is level single in NO type, if require NC type or pulse
signal, you can change it under setting of “P2-F6”. The valid height of airbag can be
adjusted under “P3-F7”
6. Loop detector terminal: default is NO, if require NC, please modify the setting of
“P2-F5” to be “1”. Loop detector signal is only valid under automatic control mode,
invalid under manual control mode.
7. Small door interlock terminal: default is NC, if require to connect with small door,
please remove the jumper wire between “DIND” and “COM”