Instructions for INDUS-E SERIES Industrial Door Operator
www.gatexpertstore.com
17
P2-F8
Restore to factory setting of P2
0=No
;
1=Yes
0
P3
P3-F1
Multi-function of F1
0=NO
;
1=NC
0
P3-F2
Multi-function of F2
0=NO
;
1=NC
0
P3-F3
F1
Close
0
0
Fault output
1
Door completely open in place
output
2
Door partially open in place output
3
Not open limit switch output
4
Closed in place output
5
Not closed limit switch output
6
Door in running output
7
Air curtain signal output
8
Force on
9
P3-F4
F2
Same as P3-F3
P3-F5
Inter-lock function
0=Disable
;
1=Enable
0
P3-F6
Limit height of infrared photocell valid
1-1500
100
P3-F7
Limit height of airbag valid
1-1500
50
P3-F8
Locked rotor time
1-7
4
P3-F9
Restore to factory setting of P3
0=No
;
1=Yes
0
P4
P4-F1
Alarm of running over the open limit
switch
10-200
80
P4-F2
Alarm of running over the closed limit
switch
10-200
100
P4-F3
Open limit switch position check
Read only
P4-F4
Closed limit switch position check
Read only
P4-F5
Current position check
Read only
P4-F6
Restore to factory setting of P4
0=No
;
1=Yes
0
P4-A3
Display backlight selection
0=60sec.
automatically
energy saving
;
1=always on
0
P5
(
Initial password
:
00000
)
P5-F1
Total running times setting
0-99999
99999
P5-F2
Total running days setting
0-99999
99999
P5-F3
Total running days checking
Read only
P5-F4
Total running times checking
Read only
P5-F5
Change your password
00000-99999
00000
P5-F6
Restore to factory setting of P1- P4
0=No
;
1=Yes
0