Instructions for GK SERIES
www.gatexpertstore.com
12
D E
T
C O
PT
O P
C O
C L
N O
N O
C O
N C
G N
D
24
V
5V
O P
N C
LS
ST
P C
O M
D E
T
C O
PT
O P
C O
C L
N O
24
V
24
V
O U
T C
O M
24
V
with the original cam rotation direction,
the close limit switch moves up and the close position will be higher. Otherwise
close position will be lower; under normal circumstances, if the hex wrench is rotated
90 °, the close position will differ by around 25mm.
b. Precise Adjustment of Open Limit:
With the same way, rotate the micrometer
adjusting screw of two green cams until the desired open limit position is reached.
Note:
1) During debugging of door operator, please use the buttons on the control
box for operation.
2) Test several times to ensure the normal opening or closing of door, and
control box should be installed in the wall or column of 1.4 meters where the
operation of door can be observed, and to prevent children from inadvertently
touching.
Fittings Wiring
1. The signal wire of infrared sensor should be connected with PT and CO (State as
delivered is N.O.), power with "24V" and GND";
2. Airbag switch should be connected with PT and CO (State as delivered is N.O.)