GK380 Control Panel Wiring (AC 380V)
Wiring of power, motor and limit of GK60S, GK100S and GK150S three phase control box as shown below
①
Three Phase Power Wire L1, L2, L3
②
Power Neutral Wire N
③
Motor Wire (U RED, V WHITE, W BLACK)
④
Grounded Wire (E YELLOW GRENN double color)
⑤
LED2 Indicator Light
⑥
Close Limit Wire (CL RED)
⑦
Limit Common Wire (CO WHITE)
⑧
Open Limit Wire (OP GREEN)
Note: 1. Make sure the wires are securely connected. After the wiring is completed, please tighten the waterproof connector, so that the
wire is completely fixed.
2. If re-wiring, change in phase sequence which may cause the machine reverse should be avoided. Under the correct condition
of phase sequence, LED2 indicator light should be off rather than flashing.
WARNING: When connecting the power line, be sure power is off so as to avoid electric shock!