Gate

 

“auto

 

close”

 

function

 

works

 

like

  

“auto

 

open

 

  

1.

 

The

 

first

 

operation

 

should

 

be

 

defined

 

as

 

gate

 

closing

 

during

 

the

 

learning

 

mode

 

no

 

matter

 

what

 

the

 

method

 

of

 

installation

 

is.

  

2.

 

If

 

the

 

gate

 

executes

 

the

 

contrary

 

action,

 

please

 

swap

 

the

 

wiring

 

of

 

the

 

motor

 

to

 

the

 

opposite

 

polarity.

 

Gate

 

doesn’t

 

stop

 

immediately

 

when

 

it

 

reaches

 

the

 

end

 

of

 

travel.

1.

 

Adjust

 

the

 

VR1

 

to

 

decrease

 

the

 

over

 

current

 

limit.

 

Flashing

 

light

 

doesn’t

 

work.

 

Check

 

the

 

wiring

 

of

 

the

 

flashing

 

light

 

to

 

make

 

sure

 

that

 

it

 

is

 

well

 

connected

 

and

 

using

 

the

 

correct

 

polarity.

 

 

Check

 

that

 

~18V

 

AC

 

is

 

present

 

on

 

the

 

output

 

side

 

of

 

the

 

transformer.

   

Check

 

that

 

~14VDC

 

is

 

present

 

on

 

the

 

terminals

 

of

 

the

 

battery

 

when

 

the

 

unit

 

is

 

plugged

 

into

 

AC

 

and

 

that

 

at

 

least

 

~12V

 

DC

 

is

 

present

 

when

 

it

 

is

 

not

 

plugged

 

into

 

AC

 

but

 

after

 

charging.

 

 

Содержание YG-5602/1U/E

Страница 1: ...YG 5602 1U E SWINGING GATE OPENER OWNER S MANUAL...

Страница 2: ...1 2011 Gatekeeper Ltd P O Box 752 Lacey s Spring AL 35754 http www gatekeeperltd com...

Страница 3: ...d 13 7 Stopper and Latch Installation 14 8 Electrical Installation 16 8 1 Connecting the AC Power 16 8 2 Wiring the Battery see Fig 7b 17 8 3 Wiring the Actuators 17 8 4 First Time Activation Test 18...

Страница 4: ...3 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...ke sure the battery inside the opener is charged fully before using Before installation the clutch should be unlocked The auto reverse function must be checked during installation to ensure that the g...

Страница 6: ...ng code technology prevents thieves from guessing your remote code Manual key release design for emergency purposes Supports Keypad interface and Magnetic Loop Detectors simultaneously 3 Specification...

Страница 7: ...ave not already done so wire a waterproof outlet near the gate following proper safety standards for your area If you are not experienced with this type of wiring or if your area requires it hire a pr...

Страница 8: ...Through beam type infra red photo sensor 5 Electric Latch with Keylock 6 Mounting bracket 7 Antenna 8 Control box 9 Cotter Pin 10 Clevis Pin 11 Keys and manual key lock 12 Remote key Not shown in pict...

Страница 9: ...ator to your gate No Description Quantity Single Dual 1 Actuator 1 2 2 Nest Pin 1 2 3 Fastener Screw 1 2 4 L Mounting Bracket 2 4 5 Bar Mounting Bracket 1 2 6 Nut for Bolt 2 4 7 Bolt 2 4 8 Release Key...

Страница 10: ...ents 1 Actuator Maximum Direct Force 1400N 315 lbs 2 Actuator Maximum Power Consumption 12V at 6A 72W 3 Duty Cycle 50 30mm 1 2 T Mounting Bracket 150mm 5 9 20mm 78 20mm 78 20mm 78 20mm 78 8mm 31 15mm...

Страница 11: ...moothly before installing the YG 5602 swinging gate opener The gate must be plumb level and move freely More detailed instructions on page 6 Sec 5 Site Preparation Conduit In order to protect the wire...

Страница 12: ...ace of the mounting post and the opener is mounted on the face 90 degrees from it Below are schematics of both push to open and pull to open configurations A PULL TO OPEN INWARD Use this setup to make...

Страница 13: ...hould always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 4 Opening Angle A cm A inch B cm B inc...

Страница 14: ...m should always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 5 Opening Angle A cm A inch B cm B...

Страница 15: ...ectrical Latch OPTIONAL 3 Install the Electrical Latch and the Slave Gate Stop on the gate as shown in the diagram 4 Install the L Bar on the opposite gate 5 Install Stopper 1 stops gate in closed pos...

Страница 16: ...al Maintenance Regularly verify that the gate swings freely Add grease to the gate as directed by the manufacturer of the gate Check that wiring and other electrical parts are weather proof Keep opene...

Страница 17: ...e the ground usually green to the terminal on the left Wire the hot usually black wire to the middle terminal Wire the neutral usually white wire to the terminal on the right Verify that all electrica...

Страница 18: ...ing light Gate is waiting for auto close execution Lamp fixed light 7 sec without gate movement Gate is in a waiting mode since the photocell has been covered by obstacle during the gate closing or op...

Страница 19: ...need to reverse the motor operating direction No matter which method of installation is used pull to open or push to open the first operation should be defined as gate closing phase during the proced...

Страница 20: ...main button one black one on the left of the transmitter it will then be memorized up to 15 different transmitters can be memorized After the LED light is turned off the receiver module will go back t...

Страница 21: ...entation for details The keypad device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers 10 2 Loop detector A magnetic loop detector detects vehicles that are wi...

Страница 22: ...photocell remove the short circuit wire between Terminals 14 and 15 Attach the normally closed wire to 14 and the other common normally closed wire to 15 COM Attach the 12VDC power for the photocell t...

Страница 23: ...gate operation J4 11 use with 12 Keypad Pushbutton for the single gate operation J4 12 Logical and Power Ground for external devices J4 13 Positive Supply 12V DC J4 14 15 Photo sensor contacts must b...

Страница 24: ...VDC Max current 3A J3 Terminal block 7 8 Connect to the flashing light 12VDC Max power 15W J4 Terminal block 13 ve 12 ve Connect to the external receiver board for the 12 V DC Positive and Gnd Negativ...

Страница 25: ...24 11 1 Visual Guide for Wiring...

Страница 26: ...hen an obstruction is placed in its path then the setting may be too high Start with just above the minimum value and tune it to use the minimum setting for which the gate will function WARNING Do not...

Страница 27: ...ON Auto close On waiting time 12 seconds Cancel auto close function Move the fourth and fifth DIP switches to the off position in order to disable the auto close feature 14 Additional Features LIGHT...

Страница 28: ...c If any command transmitter keypad or photocell or other abnormal case interrupts the leaf s motion before it moves to the end of travel the gate can only be operated with slow down speed for the res...

Страница 29: ...to make sure that the battery and transformer J7 J8 is well connected The gate stopped during the operation opening or closing 1 Check to make sure that the Reset switch is on and that the reset swit...

Страница 30: ...t stop immediately when it reaches the end of travel 1 Adjust the VR1 to decrease the over current limit Flashing light doesn t work Check the wiring of the flashing light to make sure that it is wel...

Страница 31: ...implied Gatekeeper Ltd specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose It is the purchaser s sole and exclusive responsibility to determine...

Страница 32: ...erltd com For updated versions of the manual see http www gatekeeperltd com For Additional Remotes Infrared Photo Cells or Parts please contact your dealer To locate a dealer please visit us at www ga...

Отзывы: