background image

5

  

2.

 

Features

 

Class

 

I:

 

A

 

vehicular

 

gate

 

opener

 

(or

 

system)

 

intended

 

solely

 

for

 

use

 

in

 

a

 

single

 

family

 

home,

 

or

 

an

 

associated

 

garage

 

or

 

parking

 

area.

 

 

ADDITIONAL FEATURES 

 

Supports

 

single

 

or

 

dual

 

gate

 

operation.

 

 

Adjustable

 

auto

 

reverse

 

function

 

for

 

safety

 

purposes.

 

 

Built

in

 

battery

 

backup

 

in

 

the

 

event

 

of

 

power

 

loss.

 

 

Auto

close

 

feature

 

with

 

3

 

wait

 

times:

 

12/25/50

 

selectable

 

by

 

dip

 

switch.

 

 

Battery

 

low

voltage

 

detection

 

to

 

avoid

 

battery

 

damage.

 

 

Automatic

 

slow

 

down

 

feature

 

to

 

decrease

 

noisy

 

closing.

 

 

Keypad

 

/

 

single

 

button

 

interface.

 

 

Infrared

 

safety

 

beam

 

interface.

 

 

Supports

 

up

 

to

 

15

 

RF

 

remotes,

 

2

 

included.

 

 

User

 

programmable

 

and

 

user

 

erasable

 

remote

 

codes.

 

 

RF

 

hopping

 

code

 

technology

 

prevents

 

thieves

 

from

 

guessing

 

your

 

remote

 

code.

 

 

Manual

 

key

 

release

 

design

 

for

 

emergency

 

purposes.

 

 

Supports

 

Keypad

 

interface

 

and

 

Magnetic

 

Loop

 

Detectors

 

simultaneously.

 

 

3.

 

Specifications

 

Power

 

Supply

 

U

 

Model

 

110V

 

AC

 

(60Hz)

 

E

 

Model

 

230V

 

AC

 

(50Hz)

 

Backup

 

Battery:

 

12VDC

 

/

 

4AH

 

Maximum

 

Number

 

of

 

Remote

 

Controls

 

15

 

(2

 

Included)

 

Maximum

 

Gate

 

Weight

 

300

 

KG

 

/

 

661

 

lbs

 

Maximum

 

Gate

 

Width

 

3.6

 

meters

 

/

 

12

 

feet

 

per

 

leaf

 

Duty

 

Cycle

 

50%

 

Working

 

Temperature

 

Range:

 

20°C

 ‐ 

~55°C,

 ‐

4°F

 

 

~131°F

 

Power

 

Consumption:

 

150W

 

(Max)

 

5W

 

(Standby)

 

Power

 

Supply

 

of

 

the

 

Motor

 

12VDC/8A,

 

96W

 

(MAX)

 

Power

 

Supply

 

of

 

the

 

Lamp:

 

12VDC,

 

21W

 

(MAX)

 

Power

 

Supply

 

of

 

the

 

Electric

 

Lock:

 

12VDC,

 

60W

 

(Max)

 

Power

 

Supply

 

of

 

the

 

Receiver:

 

12VDC,

 

2W

 

(Max)

 

Power

 

Supply

 

of

 

the

 

Accessories:

 

12VDC,

 

3W

 

(Max)

 

Over

current

protection:

 

3.5A~7.5A

 

Pause

 

Time:

 

Programmable,

 

0

 

sec

 

~

 

50

 

sec

 

2

nd

 

Leaf

 

Closing

 

Delay:

 

Programmable,

 

0

 

sec

 

~

 

8sec

 

Содержание YG-5602/1U/E

Страница 1: ...YG 5602 1U E SWINGING GATE OPENER OWNER S MANUAL...

Страница 2: ...1 2011 Gatekeeper Ltd P O Box 752 Lacey s Spring AL 35754 http www gatekeeperltd com...

Страница 3: ...d 13 7 Stopper and Latch Installation 14 8 Electrical Installation 16 8 1 Connecting the AC Power 16 8 2 Wiring the Battery see Fig 7b 17 8 3 Wiring the Actuators 17 8 4 First Time Activation Test 18...

Страница 4: ...3 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 5: ...ke sure the battery inside the opener is charged fully before using Before installation the clutch should be unlocked The auto reverse function must be checked during installation to ensure that the g...

Страница 6: ...ng code technology prevents thieves from guessing your remote code Manual key release design for emergency purposes Supports Keypad interface and Magnetic Loop Detectors simultaneously 3 Specification...

Страница 7: ...ave not already done so wire a waterproof outlet near the gate following proper safety standards for your area If you are not experienced with this type of wiring or if your area requires it hire a pr...

Страница 8: ...Through beam type infra red photo sensor 5 Electric Latch with Keylock 6 Mounting bracket 7 Antenna 8 Control box 9 Cotter Pin 10 Clevis Pin 11 Keys and manual key lock 12 Remote key Not shown in pict...

Страница 9: ...ator to your gate No Description Quantity Single Dual 1 Actuator 1 2 2 Nest Pin 1 2 3 Fastener Screw 1 2 4 L Mounting Bracket 2 4 5 Bar Mounting Bracket 1 2 6 Nut for Bolt 2 4 7 Bolt 2 4 8 Release Key...

Страница 10: ...ents 1 Actuator Maximum Direct Force 1400N 315 lbs 2 Actuator Maximum Power Consumption 12V at 6A 72W 3 Duty Cycle 50 30mm 1 2 T Mounting Bracket 150mm 5 9 20mm 78 20mm 78 20mm 78 20mm 78 8mm 31 15mm...

Страница 11: ...moothly before installing the YG 5602 swinging gate opener The gate must be plumb level and move freely More detailed instructions on page 6 Sec 5 Site Preparation Conduit In order to protect the wire...

Страница 12: ...ace of the mounting post and the opener is mounted on the face 90 degrees from it Below are schematics of both push to open and pull to open configurations A PULL TO OPEN INWARD Use this setup to make...

Страница 13: ...hould always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 4 Opening Angle A cm A inch B cm B inc...

Страница 14: ...m should always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 5 Opening Angle A cm A inch B cm B...

Страница 15: ...ectrical Latch OPTIONAL 3 Install the Electrical Latch and the Slave Gate Stop on the gate as shown in the diagram 4 Install the L Bar on the opposite gate 5 Install Stopper 1 stops gate in closed pos...

Страница 16: ...al Maintenance Regularly verify that the gate swings freely Add grease to the gate as directed by the manufacturer of the gate Check that wiring and other electrical parts are weather proof Keep opene...

Страница 17: ...e the ground usually green to the terminal on the left Wire the hot usually black wire to the middle terminal Wire the neutral usually white wire to the terminal on the right Verify that all electrica...

Страница 18: ...ing light Gate is waiting for auto close execution Lamp fixed light 7 sec without gate movement Gate is in a waiting mode since the photocell has been covered by obstacle during the gate closing or op...

Страница 19: ...need to reverse the motor operating direction No matter which method of installation is used pull to open or push to open the first operation should be defined as gate closing phase during the proced...

Страница 20: ...main button one black one on the left of the transmitter it will then be memorized up to 15 different transmitters can be memorized After the LED light is turned off the receiver module will go back t...

Страница 21: ...entation for details The keypad device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers 10 2 Loop detector A magnetic loop detector detects vehicles that are wi...

Страница 22: ...photocell remove the short circuit wire between Terminals 14 and 15 Attach the normally closed wire to 14 and the other common normally closed wire to 15 COM Attach the 12VDC power for the photocell t...

Страница 23: ...gate operation J4 11 use with 12 Keypad Pushbutton for the single gate operation J4 12 Logical and Power Ground for external devices J4 13 Positive Supply 12V DC J4 14 15 Photo sensor contacts must b...

Страница 24: ...VDC Max current 3A J3 Terminal block 7 8 Connect to the flashing light 12VDC Max power 15W J4 Terminal block 13 ve 12 ve Connect to the external receiver board for the 12 V DC Positive and Gnd Negativ...

Страница 25: ...24 11 1 Visual Guide for Wiring...

Страница 26: ...hen an obstruction is placed in its path then the setting may be too high Start with just above the minimum value and tune it to use the minimum setting for which the gate will function WARNING Do not...

Страница 27: ...ON Auto close On waiting time 12 seconds Cancel auto close function Move the fourth and fifth DIP switches to the off position in order to disable the auto close feature 14 Additional Features LIGHT...

Страница 28: ...c If any command transmitter keypad or photocell or other abnormal case interrupts the leaf s motion before it moves to the end of travel the gate can only be operated with slow down speed for the res...

Страница 29: ...to make sure that the battery and transformer J7 J8 is well connected The gate stopped during the operation opening or closing 1 Check to make sure that the Reset switch is on and that the reset swit...

Страница 30: ...t stop immediately when it reaches the end of travel 1 Adjust the VR1 to decrease the over current limit Flashing light doesn t work Check the wiring of the flashing light to make sure that it is wel...

Страница 31: ...implied Gatekeeper Ltd specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose It is the purchaser s sole and exclusive responsibility to determine...

Страница 32: ...erltd com For updated versions of the manual see http www gatekeeperltd com For Additional Remotes Infrared Photo Cells or Parts please contact your dealer To locate a dealer please visit us at www ga...

Отзывы: