Sperian Instrumentation Warranty Gas Detection Products 

General 

Sperian Protection Instrumentation, LLC (hereafter Sperian) warrants gas detectors, sensors and 
accessories manufactured and sold by Sperian, to be free from defects in materials and workmanship for 
the periods listed in the tables below.  
Damages to any Sperian products that result from abuse, alteration, power fluctuations including surges 
and lightning strikes, incorrect voltage settings, incorrect batteries, or repair procedures not made in 
accordance with the Instrument’s Reference Manual are not covered by the Sperian warranty. 
The obligation of Sperian under this warranty is limited to the repair or replacement of components 
deemed by the Sperian Instrument Service Department to have been defective under the scope of this 
standard warranty.  To receive consideration for warranty repair or replacement procedures, products 
must be returned with transportation and shipping charges prepaid to Sperian at its manufacturing 
location in Middletown, Connecticut, or to a Sperian Authorized Warranty Service Center.  It is necessary 
to obtain a return authorization number from Sperian prior to shipment. 
THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND 
REPRESENTATIONS, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE 
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. SPERIAN WILL NOT BE LIABLE FOR 
LOSS OR DAMAGE OF ANY KIND CONNECTED TO THE USE OF ITS PRODUCTS OR FAILURE OF 
ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY. 

Instrument & Accessory Warranty Periods 

Product(s) Warranty 

Period 

Biosystems PHD6, PhD

5

, PhD Lite, PhD Plus, PhD 

Ultra, Cannonball

3,

 MultiVision, Toxi, Toxi/Oxy Plus, 

Toxi/Oxy Ultra, ToxiVision, Ex Chek 

As long as the instrument is in service 

ToxiPro

®

, MultiPro 

2 years from date of purchase 

ToxiLtd

®

 

2 years after activation or 2 years after the 
“Must Be Activated By” date, whichever 
comes first 

Toxi3Ltd

®

 

3 years after activation or 3 years after the 
“Must Be Activated By” date, whichever 
comes first 

Mighty-Tox 2 
Prorated credit is given towards repair or purchase of a 
new unit of the same type.  

  0 –  6  months of use  100%  credit 
  6 – 12  months of use   75%  credit 
 12 – 18  months of use   50%  credit 
 18 – 24  months of use   25%  credit 

IQ Systems, Series 3000, Airpanel, Travelpanel, 
ZoneGuard, Gas

9

Chek1 and Gas

9

Chek4 

One year from the date of purchase 

Battery packs and chargers, sampling pumps and 
other components, which by their design are 
consumed or depleted during normal operation, or 
which may require periodic replacement 

One year from the date of purchase 

Sensor Warranty Periods 

Instrument(s) 

Sensor Type(s) 

Warranty Period 

O

2

, LEL**, CO, CO+, H

2

S & 

Duo-Tox 

2 Years 

Biosystems PHD6, PhD Plus, PhD Ultra, PhD

5

PhD Lite, Cannonball

3

, MultiVision,

 

MultiPro, 

ToxiVision,

 

ToxiPro

®

, Ex Chek 

All Other Sensors 

1 Year 

CO, CO+, H

2

S 2 

Years 

Toxi, Toxi/Oxy Plus, Toxi/Oxy Ultra 

All Other Sensors 

1 Year 

All Others 

All Sensors 

1 Year 

**  Damage to combustible gas sensors by acute or chronic exposure to known sensor poisons such 
as volatile lead (aviation gasoline additive), hydride gases such as phosphine, and volatile silicone 
gases emitted from silicone caulks/sealants, silicone rubber molded products, laboratory glassware 
greases, spray lubricants, heat transfer fluids, waxes & polishing compounds (neat or spray aerosols), 
mold release agents for plastics injection molding operations, waterproofing formulations, vinyl & 
leather preservatives, and hand lotions which may contain ingredients listed as cyclomethicone, 
dimethicone and polymethicone (at the discretion of Sperian’s Instrument Service department) void 
Sperian Instrumentation’s Standard Warranty as it applies to the replacement of combustible gas 
sensors. 

Содержание ToxiPro

Страница 1: ...ToxiPro S ing le G as Detec tor R eferenc e M anual GasTech Australia Pty Ltd 24 Baretta Rd Wangara Western Australia 6065 Tel 1800 999 902 Fax 1800 999 903 http www gastech com au ...

Страница 2: ...E INSTRUCTIONS IN THIS REFERENCE MANUAL BE READ FULLY UNDERSTOOD AND FOLLOWED ToxiPro Reference Manual Sperian Instrumentation Part Number 13 264 Version 2 01 Copyright 2008 by Sperian Protection Instrumentation LLC Middletown Connecticut 06457 All rights reserved No page or part of this operation manual may be reproduced in any form without written permission of the copyright owner shown above Sp...

Страница 3: ...kout 8 2 2 Backlight 8 2 3 Functions 8 2 4 Calibration and bump test due notices 8 2 5 Low battery alarms 9 2 6 Turning the ToxiPro off 9 2 7 Always On Mode 9 2 7 1 Turning Off in Always On Mode 9 2 8 Sampling 9 2 8 1 Sample draw kit usage 9 3 Calibration 10 3 1 Verification of accuracy 10 3 1 1 Verifying accuracy and response ToxiPro O2 10 3 1 2 Verifying accuracy ToxiPro with toxic gas sensor 10...

Страница 4: ...erian Instrumentation Warranty Gas Detection Products 18 Operating Temperature Range The safe operating temperature range of the gas detector is printed on the back label of the instrument Use of Sperian Gas Detectors outside of the instrument s specified operating temperature range may result in inaccurate and potentially dangerous readings Certifications The ToxiPro carries the following certifi...

Страница 5: ...accurate and potentially dangerous readings The ToxiPro O2 should be periodically calibrated in fresh air 5 A sensor that cannot be calibrated or is found to be out of tolerance must be replaced immediately An instrument equipped with a toxic gas sensor that fails calibration may not be used until testing with known concentration test gas determines that accuracy has been restored and the instrume...

Страница 6: ... B 1 2 2 ToxiPro O2 sensor ranges The oxygen sensor used in the ToxiPro O2 has a range of 0 30 by volume 1 2 3 ToxiPro O2 warm up phase The ToxiPro O2 requires a one time 15 minute warm up phase prior to initial activation See section 2 1 for further details 1 3 Alarm and warning logic 1 3 1 Gas alarms ToxiPro gas alarms are user adjustable and may be set anywhere within the range of the specific ...

Страница 7: ...n A built in manually activated backlight allows the display to be read even in low light conditions Visual alarm LED IrDA port A bright red LED Light Emitting Diode alarm light provides a visual indication of the alarm state The LED also functions as the IrDA port MODE button The large push button on the front of the instrument is called the MODE button The MODE button is used to turn the ToxiPro...

Страница 8: ...hat the 6 digit serial number can not fit on a single screen so it is shown on two screens In this case the instrument serial number is 481098 Datalogging versions will then show the dL screen Once the sensor is recognized the instrument will display the sensor type The warning alarm level will then be displayed followed by the danger alarm level During the display of the warning alarm level the L...

Страница 9: ...the MAX screen press the MODE button to view the time screen A dot below the colon between the hours and the minutes digits indicates afternoon evening hours pm 10 45 am 10 45 pm If the STEL Short Term Exposure Limit alarm is enabled press the MODE button once to view the STEL reading The STEL value displayed represents the average value of the instrument readings for the target gas for the most r...

Страница 10: ...re Note The ToxiPro must be turned off to replace the battery See section 2 7 1 2 7 1 Turning Off in Always On Mode BioTrak software must be used to turn the ToxiPro off when it is in Always on Mode BioTrak is available at http www biodownloads com 1 Open BioTrak and select ToxiPro 2 Select Configure in the software 3 Hold the MODE button down for about 10 seconds until IrDA is shown and establish...

Страница 11: ...ds then slowly exhale directly onto the face of the sensor in the same way you would to fog up a piece of glass If the descending oxygen alarm is set to 19 5 the instrument should go into alarm after a few seconds 3 1 2 Verifying accuracy ToxiPro with toxic gas sensor Verification of accuracy is a two step procedure for ToxiPro instruments equipped with a toxic gas sensor Step one is to take the T...

Страница 12: ... between the following two screens 3 For instruments equipped with a toxic gas sensor the fresh air zero calibration is complete when the instrument begins a second 5 second countdown for the span calibration If span calibration is not required allow the countdown to reach 0 without pressing the MODE button For further instructions concerning the span calibration of toxic sensor equipped models pr...

Страница 13: ...ibration is fully automatic from this point on Once the instrument successfully completes the span calibration it will emit three short beeps and display the maximum span calibration adjustment value for two seconds Note The maximum span calibration adjustment value shown is an indication of the relative health of the sensor As a sensor loses sensitivity the maximum adjustment level will approach ...

Страница 14: ...an calibration failure in which calibration gas is not detected the no and GAS screens will be alternately displayed as shown below with the calibration bottle icon highlighted When the instrument returns to the current gas readings screen the warning symbol and the calibration bottle icon will be shown which signifies that the last attempt to span calibrate the instrument has failed Note If the C...

Страница 15: ...utomatically restart with the hours digits blinking The next five steps describe programming the time and date 7 Press and release the MODE button to advance the setting by one Hold the MODE button down to scroll rapidly Afternoon and evening hours are differentiated by a dot below the colon on the display 10 a m 10 p m Once the appropriate hour setting is shown wait 5 seconds and the minutes sett...

Страница 16: ... instrument functionality 4 4 Storage ToxiPro detectors may be stored for long periods in a fresh air environment at temperatures between 10 C 50 F and 30 C 86 F 5 PC Instrument Communications 5 1 Event logging Each ToxiPro includes a built in event logger that stores instrument readings during alarm conditions calibration values and other data BioTrak software and an IrDA port are necessary to do...

Страница 17: ... 50 150 0 2 n d n d 0 Nitrogen Dioxide NO2 5 8 1 0 100 90 270 0 n d n d 0 n d n d Chlorine Cl2 specific 0 3 0 n d 12 100 20 0 0 0 0 0 0 Chlorine Dioxide ClO2 specific 0 25 0 n d n d 60 100 0 0 0 n d 0 0 Ammonia NH3 54 47 21 0 5 0 n d 0 0 n d 0 0 0 100 0 0 Phosphine PH3 0 5 25 20 n d 0 1 n d n d n d 1 0 5 Hydrogen Cyanide HCN 0 5 350 160 5 100 20 60 0 1 100 65 5 50 n d n d no data undetermined posi...

Страница 18: ...mmends the following procedure to establish a safe and prudent accuracy check schedule for your Sperian instruments 1 During a period of initial use of at least 10 days in the intended atmosphere check the sensor response daily to be sure there is nothing in the atmosphere that is poisoning the sensor s The period of initial use must be of sufficient duration to ensure that the sensors are exposed...

Страница 19: ... is in service ToxiPro MultiPro 2 years from date of purchase ToxiLtd 2 years after activation or 2 years after the Must Be Activated By date whichever comes first Toxi3Ltd 3 years after activation or 3 years after the Must Be Activated By date whichever comes first Mighty Tox 2 Prorated credit is given towards repair or purchase of a new unit of the same type 0 6 months of use 100 credit 6 12 mon...

Страница 20: ...xiPro c UL Version ATEX CQST Version IECEx Version Type O2 H2S SO2 CO CO H CO NH3 Cl2 ClO2 NO2 HCN PH3 SO2 Hi Software Version _____ Vibrating Motor Datalogging Belt Clip Serial Number ____________ MFG Date ...

Отзывы: