- 23 -
GB
The specifications of the power supply connection flexible cable must match or be superior to those of the cable with rubber
insulation H07RN-F. Introduce the cable through the cable clamp and secure it firmly. In addition, the supply voltage,
during operation, should not differ from the voltage rating by +/-10%.
The unit is supplied with a cable with the specifications given in Tab. 3; to access the terminal block or replace it,
you need to:
- Remove the terminal-block box on the back of the unit
- Connect the supply cable to the terminal block according to need, following the instructions given on the label located
near the terminal block and in this booklet.
CONNECTIONS TO THE ELECTRICITY MAINS
POWER SUPPLY CABLE
1N AC 220...240 V 50 Hz
PE
(Terra)
yellow-green
N
(NP)
blue
L
1
(R)
brown
MODEL
G4SF6 - G6SF6 - G6SFA6
TYPE OF VOLTAGE
AC 220...240 V 50 Hz
WIRING DIAGRAM
DRAWING No.
No. cabels
m m
2
Max.
A/f
7,8
* = 230 V ~ 50/60 Hz
3 x 1,5
3.1
HOB
Take off the grills, burner lid and burner body.
REPLACING THE PLATE BURNER NOZZLE
Replace the nozzle (Fig. 2 pos. 10) of the burner (size-8 wrench) with one corresponding to the type of gas chosen, following
Tables II Injectors Sect. 3.4.0.
REPLACING THE “BY-PASS” MINIMUM SCREW
- Replace the minimum thermal capacity screw, by-pass (Fig. 2 pos. 2) with the one corresponding to the type of gas chosen,
following Tables II Injectors Sect. 2.5
- The thermal capacity on the minimum position must be approximately 30% of the nominal thermal capacity.
- When you turn the knob fast from the maximum position ( ) to the minimum position ( ) the burner must neither go
out nor backfire.
3.
TRANSFORMATION FOR OPERATION WITH ANOTHER TYPE OF GAS