RECOMMENDED A C C E S S O R I E S

Model Number

R1, R2

R3

R4, SDR4,  R4H, R6, R6P, R6PS

R7, R7S

R6PP, R9

R7P

R4P, R5 

SDR6P, SDR6

Exhaust

Exhaust

Part Number

AJ121B

AJ121C

AJ121D

AJ121F

AJ121G

AJ121H

AJ121M

Dimension (A)

7.46”

7.94”

12.75”

17.05”

17.44”

20.30”

33.60”

Dimension (B)

2.38”

2.62”

3.25”

3.63”

4.25”

4.75”

6.00”

Dimension (C)

1.00” NPT

1.25” NPT

1.50” NPT

2.00” NPT

2.50” NPT

3” NPT

4”NPT

Model Number

R1, R2

R3

R4, R4H, R4P

SDR5, R6, SDR6,

SDR6P, R7,

R9, R9P,

SDR4, R5

R5P, R6PP, R6PS R7P, R7S

R9S

Part Number

AJ126B

AJ126C

AJ126D

AJ126F

AJ126G

AJ126M

Dimension (A)

6.00”

6.00”

7.70”

10.62”

10.00”

16.00”

Dimension (B)

4.62”

7.12”

7.12”

4.81”

13.12”

14.62”

Dimension (C)

1.00” MPT

1.25” MPT

1.50” MPT

2.00” FPT

2.50” MPT

5” MPT

Replacement

AJ134B

AJ134C

AJ134E

AG340

AJ135A

AJ135H

Element

Micron

10

10

10

10

10

10

INLET FILTERS (FOR PRESSURE)

All filters are heavy duty for high-particulate service.  Inlet filters for
Regenair blowers are drip-proof when mounted as shown..

MPT = Male Pipe Thread
FPT = Female Pipe Thread

MUFFLERS

Designed to reduce noise by up to 5 dbA and remove
high-frequency sound associated with all blowers.

9

PARTS & ORDERING INFORMAT I O N

REF#

ITEM    

QTY

R1102        

R2103   

R2105    

R2305B    

R3105-1

R1102C          R2303A

R3305A-1

R1102K

R3305B-1

1

COVER

1

AJ101A

AJ101B

AJ101B

AJ101B

AJ101C

2

LOCK NUT

1

BC187

BC187

BC181

BC181

BC181

3

IMPELLER

1

AJ102A

AJ102BQ

AJ102B

AJ102B

AJ102C

4

SQUARE KEY

1

AH212C

AH212

AB136A

AB136A

AB136A

5

SHIM SPACER

AE686-5

AE686-3

AJ109

AE686-3

AJ109

6

RETAINING RING

1

AJ145

AJ145

AJ149

AJ145

AJ149

7

HOUSING

1

AJ103A

AJ103BQ

AJ103B

AJ103B

AJ103C

8

-

9

-

10A

FOAM

AJ112A(4)

AJ112BQ(6) AJ112BQ(6)

AJ112BQ(6)

AJ112C(4)

10B

FOAM

2

AJ112CQ

11

MUFFLER EXTENSION

1

AJ106A

AJ106BQ

AJ106BQ

AJ106BQ

AJ106CQ

Please reference the exploded view on Page 11 for the following model and parts table.

As required.

Parts listed are for stock models.  For specific OEM models, please consult the factory.

When corresponding or ordering parts, please give complete model and serial numbers.

70-6000 REV J.qxd  7/23/07  2:54 PM  Page 9

Содержание R2303A

Страница 1: ...R6P350A Shown Model R7P Shown Product Use Criteria Pump only clean dry air Operate at 20ºF 104ºF 29ºC 40ºC Protect unit from dirt moisture Do not pump flammable or explosive gases or use in an atmosphere that contains such gases Protect all surrounding items from exhaust air This exhaust air can become very hot Corrosive gases and particulate material will damage unit Water vapor oil based contami...

Страница 2: ...install check valves that close with a strong spring The recommended check valves page 7 provide minimal pressure drop positive sealing and are resistant to the high discharge temperatures of large blowers WARNING DANGER Plumbing Remove any foreign material burrs chips welding drops slag pipe cuttings excess sealant sand or lime from plumbing Check motor mounting and rotation before connecting to ...

Страница 3: ...d that has a 3 blade grounding plug Connect extension cord plug to a matching 3 slot receptacle Do not use an adapter Make sure your extension cord is in good condition Check that the gage wire of the extension cord is the correct size wire to carry the current this product will draw An undersized cord is a potential fire hazard and will cause a drop in line voltage resulting in loss of power caus...

Страница 4: ...urning in the proper direction MAINTENANCE It is your responsibility to regularly inspect and make necessary repairs to this product in order to maintain proper operation Make sure that pressure and vacuum is released from product before starting maintenance Check filter elements and noise absorbing foam used in mufflers and clean motor and blower after first 500 hours of operation Replace filter ...

Страница 5: ...ther as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOODS SUPPLIED OR FOR NON DELIVERED GOODS OR FAILURE TO FURNISH GOODS WHETHER OR NOT BASED ON NEGLIGENCE STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY IS LIMITED SOLELY AT GAST S OPTION TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON...

Страница 6: ... High Voltage Low Voltage High Voltage T14 T15 T16 T4 T5 T6 T7 T8 T9 T1 T2 T3 To reverse rotation on any 3 Phase motor interchange any two external motor line connections to any two line leads Models R2303A R3305A 1 R3305A 13 R4310A 2 R4P315A R6350A 2 R6P350A R6PP3110M R6PS3110M R7100A 3 R7P3180M R7S3180M R93150A Connections for 3 Phase 12 Leads Models R6335A 2 R6P335A Models R5325A 2 R6325A 2 BEF...

Страница 7: ...5 SDR4 R6 R6P SDR6P R7 R7S SDR4 R4P SDR6 R6PS Part Number AH326B AH326C AH326D AH326F AH326G Dimension A 3 57 4 19 4 50 5 25 8 00 Dimension B 2 32 2 69 2 94 3 82 5 07 Dimension C 1 00 NPT 1 25 NPT 1 50 NPT 2 00 NPT 2 50 NPT MOISTURE SEPARATOR FOR VACUUM This moisture separator removes liquids from the gas stream in a vacuum process This helps protect the blower from corrosion and the build up of m...

Страница 8: ...odel Number R1 R2 R3 R4 SDR4 R4P SDR5 SDR6 R6 R6PP SDR6P R7S R9 R4H R5 R6P R7M R6PS R7 R7S R9P R9S Part Number AJ151A AJ151B AJ151C AJ151D AJ151E AJ151G AJ151H AJ151M Dimension A 5 88 7 38 7 38 7 38 8 75 8 75 14 00 18 50 Dimension A1 16 25 20 75 Dimension B 4 50 6 81 6 81 6 81 10 25 10 50 27 13 28 13 Dimension C 2 75 4 62 4 62 4 62 5 00 5 50 18 50 19 50 Dimension D 1 00 FPT 1 00 FPT 1 25 FPT 1 50 ...

Страница 9: ...blowers are drip proof when mounted as shown MPT Male Pipe Thread FPT Female Pipe Thread MUFFLERS Designed to reduce noise by up to 5 dbA and remove high frequency sound associated with all blowers 9 PARTS ORDERING INFORMATION REF ITEM QTY R1102 R2103 R2105 R2305B R3105 1 R1102C R2303A R3305A 1 R1102K R3305B 1 1 COVER 1 AJ101A AJ101B AJ101B AJ101B AJ101C 2 LOCK NUT 1 BC187 BC187 BC181 BC181 BC181 ...

Страница 10: ...BB750 2 BB750 2 BB750 BB750 3 IMPELLER 1 AJ102K AJ102KA 2 AJ102KA 2 AJ102GZ AJ102GA 4 SQUARE KEY 1 AB136 AB136 2 AB136 2 AC628 AC628 5 SHIM SPACER AJ109 AJ169F AJ169F AJ110 AJ110 6 RETAINING RING 1 7 HOUSING 1 AJ103K AJ103KD 2 AJ103KD 2 AJ103GA AJ103GA 8 MUFFLER BOX 1 AJ104K AJ104GA AJ104GA 8A SCREEN 2 AJ998G AJ998G 9 SPRING 2 AJ113FQ 10A FOAM AJ112K 8 AJ112GA 8 AJ112GA 8 10B FOAM 2 11 MUFFLER EXT...

Страница 11: ...EXPLODED PRODUCT VIEW 11 ...

Страница 12: ...y Operating at too high a pressure or Install a relief valve and pressure or vacuum vacuum gauge Unusual sound Impeller is damaged or dirty Clean or replace impeller Bearing going bad Send unit to a Gast Authorized Service Facility Motor overload Low voltage Check power source Check wire size and wire connections Unit does not start Incorrect electrical connection or Check wiring diagram circuit f...