Gast R2303A Скачать руководство пользователя страница 5

Gast finished products, when properly installed and operated under normal conditions of use, are warranted by Gast to be free
from defects in material and workmanship for a period of twelve (12) months from the date of purchase from Gast or an
authorized Gast Representative or Distributor. In order to obtain performance under this warranty, the buyer must promptly (in no
event later than thirty (30) days after discovery of the defect) give written notice of the defect to Gast Manufacturing
Incorporated, PO Box 97, Benton Harbor Michigan USA 49023-0097 or an authorized Service Center (unless specifically agreed
upon in writing signed by both parties or specified in writing as part of a Gast OEM Quotation). Buyer is responsible for freight
charges both to and from Gast in all cases.

This warranty does not apply to electric motors, electrical controls, and gasoline engines not supplied by Gast. Gast’s warranties
also do not extend to any goods or parts which have been subjected to misuse, lack of maintenance, neglect, damage by
accident or transit damage.

THIS EXPRESS WARRANTY EXCLUDES ALL OTHER WARRANTIES OR REPRESENTATIONS EXPRESSED OR IMPLIED
BY ANY LITERATURE, DATA, OR PERSON. GAST’S MAXIMUM LIABILITY UNDER THIS EXCLUSIVE REMEDY SHALL
NEVER EXCEED THE COST OF THE SUBJECT PRODUCT AND GAST RESERVES THE RIGHT, AT ITS SOLE DISCRETION,
TO REFUND THE PURCHASE PRICE IN LIEU OF REPAIR OR REPLACEMENT.

GAST WILL NOT BE RESPONSIBLE OR LIABLE FOR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, however
arising, including but not limited to those for use of any products, loss of time, inconvenience, lost profit, labor charges, or other
incidental or consequential damages with respect to persons, business, or property, whether as a result of breach of warranty,
negligence or otherwise. Notwithstanding any other provision of this warranty, BUYER’S REMEDY AGAINST GAST FOR
GOODS SUPPLIED OR FOR NON-DELIVERED GOODS OR FAILURE TO FURNISH GOODS, WHETHER OR NOT BASED
ON NEGLIGENCE, STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY IS LIMITED SOLELY, AT
GAST’S OPTION, TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON-DELIVERED GOODS OR
RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND IN NO EVENT SHALL EXCEED THE PRICE OR CHARGE
FOR SUCH GOODS. GAST EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD. THERE ARE NO WARRANTIES WHICH
EXTEND BEYOND THE DESCRIPTIONS SET FORTH IN THIS WARRANTY, notwithstanding any knowledge of Gast regarding
the use or uses intended to be made of goods, proposed changes or additions to goods, or any assistance or suggestions that
may have been made by Gast personnel.

Unauthorized extensions of warranties by the customer shall remain the customer’s responsibility.

CUSTOMER IS RESPONSIBLE FOR DETERMINING THE SUITABILITY OF GAST PRODUCTS FOR CUSTOMER’S USE OR
RESALE, OR FOR INCORPORATING THEM INTO OBJECTS OR APPLICATIONS WHICH CUSTOMER DESIGNS,
ASSEMBLES, CONSTRUCTS OR MANUFACTURES.

This warranty can be modified only by authorized Gast personnel by signing a specific, written description of any modifications.

WA R R A N T Y

5

Models

R4P115, R5125-2, R6125-2

Low Voltage

High Voltage

Single Phase

Single Phase

Purple

L1

Purple                             

L1

Brown                             

Tie together

Brown                            

Insulate

Orange

& Insulate

White

Tie together

Blue

Orange

& Insulate

White

L2

Blue

Red

Red

L2

E L E C T R I C A L WIRING DIAGRAMS

Models

R1102, R2103, R2105, R3105-1, R3105-12, R4110-2

Low Voltage

High Voltage

Single Phase

Single Phase

Blue

P1

Line

P1

Line

Brown

P2

P2

Insulate

Black      

5

Tie together

5

Orange

3

& Insulate

3

Tie together

White

2

2

& Insulate

Yellow

4

Tie together Line

4

Line

70-6000 REV J.qxd  7/23/07  2:54 PM  Page 5

Содержание R2303A

Страница 1: ...R6P350A Shown Model R7P Shown Product Use Criteria Pump only clean dry air Operate at 20ºF 104ºF 29ºC 40ºC Protect unit from dirt moisture Do not pump flammable or explosive gases or use in an atmosphere that contains such gases Protect all surrounding items from exhaust air This exhaust air can become very hot Corrosive gases and particulate material will damage unit Water vapor oil based contami...

Страница 2: ...install check valves that close with a strong spring The recommended check valves page 7 provide minimal pressure drop positive sealing and are resistant to the high discharge temperatures of large blowers WARNING DANGER Plumbing Remove any foreign material burrs chips welding drops slag pipe cuttings excess sealant sand or lime from plumbing Check motor mounting and rotation before connecting to ...

Страница 3: ...d that has a 3 blade grounding plug Connect extension cord plug to a matching 3 slot receptacle Do not use an adapter Make sure your extension cord is in good condition Check that the gage wire of the extension cord is the correct size wire to carry the current this product will draw An undersized cord is a potential fire hazard and will cause a drop in line voltage resulting in loss of power caus...

Страница 4: ...urning in the proper direction MAINTENANCE It is your responsibility to regularly inspect and make necessary repairs to this product in order to maintain proper operation Make sure that pressure and vacuum is released from product before starting maintenance Check filter elements and noise absorbing foam used in mufflers and clean motor and blower after first 500 hours of operation Replace filter ...

Страница 5: ...ther as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOODS SUPPLIED OR FOR NON DELIVERED GOODS OR FAILURE TO FURNISH GOODS WHETHER OR NOT BASED ON NEGLIGENCE STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY IS LIMITED SOLELY AT GAST S OPTION TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON...

Страница 6: ... High Voltage Low Voltage High Voltage T14 T15 T16 T4 T5 T6 T7 T8 T9 T1 T2 T3 To reverse rotation on any 3 Phase motor interchange any two external motor line connections to any two line leads Models R2303A R3305A 1 R3305A 13 R4310A 2 R4P315A R6350A 2 R6P350A R6PP3110M R6PS3110M R7100A 3 R7P3180M R7S3180M R93150A Connections for 3 Phase 12 Leads Models R6335A 2 R6P335A Models R5325A 2 R6325A 2 BEF...

Страница 7: ...5 SDR4 R6 R6P SDR6P R7 R7S SDR4 R4P SDR6 R6PS Part Number AH326B AH326C AH326D AH326F AH326G Dimension A 3 57 4 19 4 50 5 25 8 00 Dimension B 2 32 2 69 2 94 3 82 5 07 Dimension C 1 00 NPT 1 25 NPT 1 50 NPT 2 00 NPT 2 50 NPT MOISTURE SEPARATOR FOR VACUUM This moisture separator removes liquids from the gas stream in a vacuum process This helps protect the blower from corrosion and the build up of m...

Страница 8: ...odel Number R1 R2 R3 R4 SDR4 R4P SDR5 SDR6 R6 R6PP SDR6P R7S R9 R4H R5 R6P R7M R6PS R7 R7S R9P R9S Part Number AJ151A AJ151B AJ151C AJ151D AJ151E AJ151G AJ151H AJ151M Dimension A 5 88 7 38 7 38 7 38 8 75 8 75 14 00 18 50 Dimension A1 16 25 20 75 Dimension B 4 50 6 81 6 81 6 81 10 25 10 50 27 13 28 13 Dimension C 2 75 4 62 4 62 4 62 5 00 5 50 18 50 19 50 Dimension D 1 00 FPT 1 00 FPT 1 25 FPT 1 50 ...

Страница 9: ...blowers are drip proof when mounted as shown MPT Male Pipe Thread FPT Female Pipe Thread MUFFLERS Designed to reduce noise by up to 5 dbA and remove high frequency sound associated with all blowers 9 PARTS ORDERING INFORMATION REF ITEM QTY R1102 R2103 R2105 R2305B R3105 1 R1102C R2303A R3305A 1 R1102K R3305B 1 1 COVER 1 AJ101A AJ101B AJ101B AJ101B AJ101C 2 LOCK NUT 1 BC187 BC187 BC181 BC181 BC181 ...

Страница 10: ...BB750 2 BB750 2 BB750 BB750 3 IMPELLER 1 AJ102K AJ102KA 2 AJ102KA 2 AJ102GZ AJ102GA 4 SQUARE KEY 1 AB136 AB136 2 AB136 2 AC628 AC628 5 SHIM SPACER AJ109 AJ169F AJ169F AJ110 AJ110 6 RETAINING RING 1 7 HOUSING 1 AJ103K AJ103KD 2 AJ103KD 2 AJ103GA AJ103GA 8 MUFFLER BOX 1 AJ104K AJ104GA AJ104GA 8A SCREEN 2 AJ998G AJ998G 9 SPRING 2 AJ113FQ 10A FOAM AJ112K 8 AJ112GA 8 AJ112GA 8 10B FOAM 2 11 MUFFLER EXT...

Страница 11: ...EXPLODED PRODUCT VIEW 11 ...

Страница 12: ...y Operating at too high a pressure or Install a relief valve and pressure or vacuum vacuum gauge Unusual sound Impeller is damaged or dirty Clean or replace impeller Bearing going bad Send unit to a Gast Authorized Service Facility Motor overload Low voltage Check power source Check wire size and wire connections Unit does not start Incorrect electrical connection or Check wiring diagram circuit f...

Отзывы: