Gast R2303A Скачать руководство пользователя страница 2

Your safety and the safety of others

is extremely important.

We have provided many important safety messages
in this manual and on your product.  Always read
and obey all safety messages.

This is the safety alert symbol.  This symbol

alerts you to hazards that can kill or hurt you and
others.  The safety alert symbol and the words
“DANGER” and “WARNING” will precede all safety
messages.  These words mean:

You will be killed or seriously injured if you don’t
follow instructions.

You can be killed or seriously injured if you don’t
follow instructions.

All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you
what can happen if the safety instructions are not
followed.  

Correct installation is your responsibility.

Make sure

you have the proper installation conditions and that
installation clearances do not block air flow.

Blocking air flow over the product in any way can
cause the product to overheat.

The blower must be installed with the properly sized
inlet filter, gauge and relief valve to protect the
product from dirt and over-heating. 

I N S TA L L AT I O N

Accessories

Install two vacuum gauges, one before and one after
filter, to monitor restriction through filters.  As filters
become clogged, performance efficiency will be
reduced.  Filters should be checked periodically and
replaced when necessary.  See page 7 for installation.  

Install a relief valve to avoid changes in pressure or
vacuum that can cause overloading of large blowers.
Install an intake filter with a relief valve to prevent
foreign material from entering blower if blower is used in
a vacuum application in a dirty environment.  In
applications where there is high humidity or liquids
being used in the process, install a moisture separator.

See Recommended Accessories on pages 7-9 or
consult your Gast Distributor/Representative for
additional filter and accessories recommendations.  Do
Not install check valves that close with a strong spring.
The recommended check valves (page 7) provide
minimal pressure drop, positive sealing and are
resistant to the high discharge temperatures of large
blowers.

WARNING

DANGER

Plumbing
Remove any foreign material (burrs, chips, welding
drops, slag, pipe cuttings, excess sealant, sand or
lime) from plumbing.

Check motor mounting and rotation before connecting
to plumbing.  Inlet and outlet ports are not designed to
support plumbing.

Remove plugs from the IN and OUT ports.  Use a small
amount of pipe thread lubricant when connecting
plumbing to protect the aluminum blower threads.
Connect with pipe and fittings that are the same size or
larger than the product’s threaded ports.  When
installing two blowers in parallel, use plumbing that is
two whole pipe sizes larger in diameter than that of the
blower.  Be sure to connect the intake and exhaust
plumbing to the correct inlet and outlet ports.

Plumbing to remove the hot discharge air of larger
blowers may be required to help maintain proper room
ambient temperature.  Use a relief valve to discharge
excess air into the atmosphere.  If the blower will be
operated at 125mbar (50” H

2

O) or higher, metal pipe is

required for hot exhaust air.

Mounting

The single impeller blower should be oriented with the
shaft in a horizontal position, unless the model’s product
features state otherwise.  The dual impeller models must
be mounted with the shaft in a horizontal position.
Mounting the product to a stable, rigid operating surface
and using shock mounts will reduce noise and vibration.

Rotation

From the motor side of the blower, check that the blower is
rotating clockwise.  (The motor side is marked with an
arrow on most models.)  Proper rotation can also be
checked by the air flow at the IN and OUT ports.  On
blowers powered by a 3-phase motor, incorrectly
connecting any two power lines can reverse direction.

Motor Installation
It is your responsibility to contact a qualified
electrician and assure that the electrical installation
is adequate and in conformance with all national
and local codes and ordinances.

2

70-6000 REV J.qxd  7/23/07  2:54 PM  Page 2

Содержание R2303A

Страница 1: ...R6P350A Shown Model R7P Shown Product Use Criteria Pump only clean dry air Operate at 20ºF 104ºF 29ºC 40ºC Protect unit from dirt moisture Do not pump flammable or explosive gases or use in an atmosphere that contains such gases Protect all surrounding items from exhaust air This exhaust air can become very hot Corrosive gases and particulate material will damage unit Water vapor oil based contami...

Страница 2: ...install check valves that close with a strong spring The recommended check valves page 7 provide minimal pressure drop positive sealing and are resistant to the high discharge temperatures of large blowers WARNING DANGER Plumbing Remove any foreign material burrs chips welding drops slag pipe cuttings excess sealant sand or lime from plumbing Check motor mounting and rotation before connecting to ...

Страница 3: ...d that has a 3 blade grounding plug Connect extension cord plug to a matching 3 slot receptacle Do not use an adapter Make sure your extension cord is in good condition Check that the gage wire of the extension cord is the correct size wire to carry the current this product will draw An undersized cord is a potential fire hazard and will cause a drop in line voltage resulting in loss of power caus...

Страница 4: ...urning in the proper direction MAINTENANCE It is your responsibility to regularly inspect and make necessary repairs to this product in order to maintain proper operation Make sure that pressure and vacuum is released from product before starting maintenance Check filter elements and noise absorbing foam used in mufflers and clean motor and blower after first 500 hours of operation Replace filter ...

Страница 5: ...ther as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOODS SUPPLIED OR FOR NON DELIVERED GOODS OR FAILURE TO FURNISH GOODS WHETHER OR NOT BASED ON NEGLIGENCE STRICT LIABILITY OR BREACH OF EXPRESS OR IMPLIED WARRANTY IS LIMITED SOLELY AT GAST S OPTION TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON...

Страница 6: ... High Voltage Low Voltage High Voltage T14 T15 T16 T4 T5 T6 T7 T8 T9 T1 T2 T3 To reverse rotation on any 3 Phase motor interchange any two external motor line connections to any two line leads Models R2303A R3305A 1 R3305A 13 R4310A 2 R4P315A R6350A 2 R6P350A R6PP3110M R6PS3110M R7100A 3 R7P3180M R7S3180M R93150A Connections for 3 Phase 12 Leads Models R6335A 2 R6P335A Models R5325A 2 R6325A 2 BEF...

Страница 7: ...5 SDR4 R6 R6P SDR6P R7 R7S SDR4 R4P SDR6 R6PS Part Number AH326B AH326C AH326D AH326F AH326G Dimension A 3 57 4 19 4 50 5 25 8 00 Dimension B 2 32 2 69 2 94 3 82 5 07 Dimension C 1 00 NPT 1 25 NPT 1 50 NPT 2 00 NPT 2 50 NPT MOISTURE SEPARATOR FOR VACUUM This moisture separator removes liquids from the gas stream in a vacuum process This helps protect the blower from corrosion and the build up of m...

Страница 8: ...odel Number R1 R2 R3 R4 SDR4 R4P SDR5 SDR6 R6 R6PP SDR6P R7S R9 R4H R5 R6P R7M R6PS R7 R7S R9P R9S Part Number AJ151A AJ151B AJ151C AJ151D AJ151E AJ151G AJ151H AJ151M Dimension A 5 88 7 38 7 38 7 38 8 75 8 75 14 00 18 50 Dimension A1 16 25 20 75 Dimension B 4 50 6 81 6 81 6 81 10 25 10 50 27 13 28 13 Dimension C 2 75 4 62 4 62 4 62 5 00 5 50 18 50 19 50 Dimension D 1 00 FPT 1 00 FPT 1 25 FPT 1 50 ...

Страница 9: ...blowers are drip proof when mounted as shown MPT Male Pipe Thread FPT Female Pipe Thread MUFFLERS Designed to reduce noise by up to 5 dbA and remove high frequency sound associated with all blowers 9 PARTS ORDERING INFORMATION REF ITEM QTY R1102 R2103 R2105 R2305B R3105 1 R1102C R2303A R3305A 1 R1102K R3305B 1 1 COVER 1 AJ101A AJ101B AJ101B AJ101B AJ101C 2 LOCK NUT 1 BC187 BC187 BC181 BC181 BC181 ...

Страница 10: ...BB750 2 BB750 2 BB750 BB750 3 IMPELLER 1 AJ102K AJ102KA 2 AJ102KA 2 AJ102GZ AJ102GA 4 SQUARE KEY 1 AB136 AB136 2 AB136 2 AC628 AC628 5 SHIM SPACER AJ109 AJ169F AJ169F AJ110 AJ110 6 RETAINING RING 1 7 HOUSING 1 AJ103K AJ103KD 2 AJ103KD 2 AJ103GA AJ103GA 8 MUFFLER BOX 1 AJ104K AJ104GA AJ104GA 8A SCREEN 2 AJ998G AJ998G 9 SPRING 2 AJ113FQ 10A FOAM AJ112K 8 AJ112GA 8 AJ112GA 8 10B FOAM 2 11 MUFFLER EXT...

Страница 11: ...EXPLODED PRODUCT VIEW 11 ...

Страница 12: ...y Operating at too high a pressure or Install a relief valve and pressure or vacuum vacuum gauge Unusual sound Impeller is damaged or dirty Clean or replace impeller Bearing going bad Send unit to a Gast Authorized Service Facility Motor overload Low voltage Check power source Check wire size and wire connections Unit does not start Incorrect electrical connection or Check wiring diagram circuit f...