3.2 TECHNICAL DATA
HCS
- Power supply voltage
10÷16 Vdc
- Max. energy consumption
250 mA
- Fuse
Internal, Self-restoring
Functioning characteristics
- Protection degree
IP 65
- Mechanic vibrations resistance
2 G
Functioning conditions
- Room temperature
-20°C / +70°C
- Weather conditions
Relative humidity 90%
Transport and storage
- Temperature
-25°C / +85°C
Speed sensor
- Power supply voltage
220 V (max)
- Max. working frequency
230 Hz (max)
- Working temperature
-20/+80 °C
- Max. operation distance
15-20 mm
- Protection degree
IP67
Cables
- Sensor connector
AMP Super seal 2-way
- Power connector
3 poles
- Functioning temperature
-20°C / +80°C
The technical data and the models provided must be consi-
dered as non binding. We reserve the right to change them
without notice.
3.0 INSTRUCTIONS FOR USE
3.1 DESCRIPTION OF HECTARE COUNTER HCS
GASPARDO hectare counters HCS
are the ideal equipment for
counting and viewing the tilled area (partial and total) as well as
for counting the hours of operation.
From software version 2.0 on, the GASPARDO HCS hectare
counter is equipped with the Self-calibration of constant “C” fun-
ction (see page 16).
A) 5-digit backlit display showing the total area, partial area and
the hours of operation.
B) Display section showing the partial area counter.
C) Display section showing the total area counter.
D) Key for partial area counter selection/resetting: during program-
ming this key is pressed to increase the value of the selected
constant.
E) ON/OFF button: hold this button pressed with the monitor on
to access the programming phase.
F) Key for total area counter selection/resetting; during program-
ming this key is pressed to reduce the value of the selected
constant.
We recommend installation of the monitor opposite the operator
so that it is easier to use during the working cycle.
Hectare counters HCS enable viewing of the following:
-
total area tilled
: 0000.0 ÷ 9999.9 Ha with 0.1 Ha pitches; if 9999.9
Ha is exceeded without resetting, the counter automatically starts
from 000.00 again.
-
partial area tilled
: 000.00 ÷ 999.99 Ha with 0.01Ha pitches; if
999.99 Ha is exceeded without resetting, the counter automati-
cally starts from 000.00 again.
-
hours of operation
: 0000.0 ÷ 9999.9 hours with 0.1 hour pitches
(6 minutes); if 9999.9 hours are exceeded without resetting, the
counter automatically starts from 0000.0 again. The hours of
operation are increased ONLY if pulses are received from the
speed sensor.
A
C
B
E
F
D
fig. 4
Содержание HCS
Страница 4: ... 4 cod G19502721 ...
Страница 12: ... 12 cod G19502721 ...
Страница 20: ... 20 cod G19502721 ...
Страница 28: ... 28 cod G19502721 ...
Страница 36: ... 36 cod G19502721 ...
Страница 44: ... 44 cod G19502721 ...
Страница 47: ...47 1 77 2 3 1 4 5 6 12 V G ...
Страница 49: ...49 1 3 6 2 9 9 ...
Страница 51: ...51 1 13 77 13 ...
Страница 52: ... 52 cod G19502721 ...
Страница 60: ... 60 cod G19502721 ...
Страница 68: ... 68 cod G19502721 ...
Страница 76: ... 76 cod G19502721 Notes ...
Страница 89: ......