![Gasmet GT5000 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/gasmet/gt5000/gt5000_quick-manual_3673991029.webp)
10/10/2023
Appendix 9 .
29
Creating new Application Libraries
Gasmet recommends that the Hazmat Application Library be kept with the 10 original gases only.
To create new application libraries, (must be in Calcmet EXPERT Mode)
–
Referencing Slide #17, Use the
follow steps to add and remove gases in the new application library :
1. Water Vapor, Carbon Dioxide, Methane and Carbon Monoxide must always be in the application.
2. Add the target gas or gases and any known other gases that maybe present in the sample such as solvents.
3. Remove any other gases from the application library that are not required.
4. Save New application : In Calcmet Expert : Options
→
Application
→
Create New Toluene_Application
Using the example of Toluene gas from slide #17 AND adding Ethanol & Isopropanol as known solvents used in the sampling area AND
removing Gases NO, SO2, NCN, HCl & HF as not deemed present in the sampling area .
Note _ When choosing an Application Name - Spaces are not allowed, use an underscore for multiple word application library names
5. Press OK to create the
new application library.
After 10
–
15 seconds the name of
the application library will change
from the original name “Hazmat” to
new name “Toluene_Application”
(This is now a new permanent
application library located in
C:\Identification Tool_SNxxxxx
Folder)