TEST FIRING HEATER
Test fire heater, following the lighting instructions on heater post. Leak test all gas connections with soapy water. Soap
bubbles indicate gas leakage.
DO NOT
use a match to test for gas leaks.
WARNING:
White smoke may appear around the radiant head during the first minute of the initial firing.
TROUBLE SHOOTING
Problem
Possible Causes
Main burner won’t light
• No gas
• Low gas pressure
• Blockage in orifice
• Manual valve not in ‘LOW’ or ‘HIGH’ position
Note:
If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Any modifications or adjustments made to product without prior authority from the manufacturer will void any warranty claims.
Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
LIGHTING INSTRUCTIONS
Warning: White smoke may appear around the radiant
head during the first minutes of the initial firing.
Step 1.
Ensure that the control knob is off. Slowly open the gas
cylinder valve.
Step 2.
Push in control knob and turn anti-clockwise to ‘HIGH’
whilst simultaneously pushing the ignitor button several
times.
Step 3.
Check for flame at the burner. If burner does not light
immediately turn control knob to ‘OFF’ position and try
again from the start. Allow 30 seconds between ignition
attempts for gas to dissipate. Several attempts may
be necessary.
Failure to follow this lighting procedure may result
in flame roll out beyond the emitter grid.
Step 4.
With the burner alight keep control knob depressed for
15 seconds.
Step 5.
For minimum heat push in and turn the control knob to ‘LOW’.
Step 6.
To turn heater off, turn the control knob to ‘OFF’.
Pus
h to
tu
rn
OFF
Pus
h to
tu
rn
OFF
LOW
HIG
H
LOW
HIG
H
7