Gasmate GM142-157 Скачать руководство пользователя страница 3

2

3

Screw the coupling nut of regulator into the cylinder valve outlet.

Q.C.C. CYLINDER CONNECTION DEVICE

Type of Gas

I3B/P-30/ULPG

Consumption

52.8 MJ/h

Operating Pressure

2.75 kPa

Injector Size

1.88mm

Appliance specifications can be found on the data label.

7.  The hose assembly should be properly located out of

 

pathways where people may trip over it. The hose

 

must be protected from contact with hot or sharp

 

surfaces both during use and while in storage. The    

 

hose assembly should be visually inspected prior to    

 

each use of the appliance. If excessive abrasion or    

 

wear is evident, or the hose is cut, it must be  

 

 

replaced prior to operating the appliance. The  

 

 

replacement hose assembly may be obtained from    

 

the distributor.

8. 

DO NOT

 use any pressure regulator or hose  

 

 

assembly other than those supplied with the  

 

 

appliance. Replacement pressure regulator and hose  

 

assembly must be those specified. Replacement parts  

 

may be obtained from the distributor.

9.  Installation and use of this appliance must conform    
 

with New Zealand Standard 5601 “Gas Installations”.

10. This appliance is designed to operate with a standard
 

9Kg LPG cylinder to DOT 4BA-240 with Approved  

 

 

Cylinder Connection.

11. The valve outlet must be maintained in good  

 

 

condition. When the cylinder is not in use, be sure to  

 

cover it with a dust cap. A leak test should be  

 

 

performed with soapy water whenever connecting    

 

a new cylinder. 

NEVER

 use a flame to test for leaks.

12. The LPG cylinder must be turned off whenever the
 

appliance is not in use. When the appliance is to be

 

stored indoors, the LPG cylinder and the appliance    

 

must be disconnected and the cylinder stored in  

 

 

accordance with LPG Dangerous Goods Regulations.

13. Store the appliance upright in an area sheltered away
 

from weather conditions. The use of a cover is

 recommended. 

14. The appliance has been designed with several safety
 

features which include a tip over switch and a flame

 

safeguard system which means if the pilot goes out   

 

the unit will automatically turn off. 

REGULATOR SAFETY FEATURE

All QCC regulators (the part that attaches to the gas 

cylinder to regulate the flow of gas) have a safety feature 
included that restricts gas flow in the event of a gas leak. 

You can inadvertently activate this safety feature without 
having a gas leak. This typically occurs when you turn 

on the gas using the appliance control knob before you 

turn on the gas cylinder valve. If the gas regulator safety 
feature activates, the appliance will operate with reduced 

output as gas flow is restricted.

These steps should be taken first to reset the gas 

regulator safety device:

1.  Turn gas cylinder valve off.

2.  Turn appliance off.

3.  Disconnect the regulator from the gas cylinder.

4.  Wait 30 seconds. 

5.  Reconnect the regulator to the gas cylinder.

6.  Leak test the connection using a soapy water solution.

 

Ensure no bubbles appear before proceeding.

7.  Slowly open the gas cylinder valve all the way. Do not
 

put excessive force on the valve at the full open  

 

 

position, to avoid damaging the valve.

8. Light the appliance as per the instructions provided. 

Any modification to the appliance not described in the

installation instructions may compromise the safety of 
this appliance. Special concern is as follows:

 (1) 

DO NOT

 bypass thermocouple safety burner;

 (2) 

DO NOT

 operate appliance without the grate 

 

    in place;

Clothing or other flammable materials should not be hung

from the appliance, or placed on or near the appliance.

The area above the burner may be extremely hot.
Direct contact with these metal surfaces should be 
avoided in order to prevent burns or clothing ignition. 

Q.C.C. CYLINDER CONNECTION DEVICE

Содержание GM142-157

Страница 1: ... installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camp...

Страница 2: ...ly must be maintained at all times when the appliance is operating Installation Operation and Maintenance Instructions 3 Proper clearance from combustible materials must be maintained at all times The minimum clearances are as follows Minimum Clearance from Combustibles Sides 1000 mm Above 1500 mm DO NOT locate this appliance under any overhead enclosure Avoid using near or under overhanging trees...

Страница 3: ...pright in an area sheltered away from weather conditions The use of a cover is recommended 14 The appliance has been designed with several safety features which include a tip over switch and a flame safeguard system which means if the pilot goes out the unit will automatically turn off REGULATOR SAFETY FEATURE All QCC regulators the part that attaches to the gas cylinder to regulate the flow of ga...

Страница 4: ... connection or the hose NEVER attempt to use damaged equipment EXPLODED DIAGRAM 3 When connecting the hose to the cylinder tighten the nut to a positive stop by hand 4 Open cylinder valve fully If a leak can be heard at either end of the hose turn cylinder off and tighten joint Wait 5 minutes before re testing and use a soapy water solution to check the joint If bubbles appear the connection will ...

Страница 5: ...ight Leg Lid Front Left Leg Back Left Leg 1 3 1 1 1 1 1 1 2 Gas Valve Panel 1 3 9 Door Knob 1 10 Base Frame Ceramic Tile 1 4 11 12 Cushion Pad 16 13 Lava Rock 1 14 4 5 6 8 7 Picture Qty Part Picture Qty 4 18 M5 x 12 4 12 4 M5 x 20 M6 x 12 ST4 2 x 9 5 M5 x 12 Hardware E A C B D Picture Qty Dimensions ...

Страница 6: ...EP 1 Place the table top frame 1 upside down on to a level surface attach control panel assembly 3 to the table top frame 1 with 4 M5x12 bolts assembly E Insert valve into the injection pipe of burner as illustrated 1 Insert the end of electrode wire into valve as illustrated 2 Adjust the distance between the ignition pin and flame orifice to be 4 5mm in case of ignition failure If ignition failur...

Страница 7: ...12 Bolt M5 x 20 Bolt M6 x 12 Bolt ST4 2 x 9 5 Bolt Qty 4 Qty 20 Qty 4 Qty 16 Qty 4 AA CC DD EE BB 7 A 6 pcs STEP 4 Attach one side panel 2 to back right leg 4 and back left leg 7 with 6 M5x12 bolts A M5 x 12 Bolt Assembly M5 x 12 Bolt M5 x 20 Bolt M6 x 12 Bolt ST4 2 x 9 5 Bolt Qty 4 Qty 20 Qty 4 Qty 16 Qty 4 AA CC DD EE BB A 6 pcs 8 7 7 4 FL BR BL BL ...

Страница 8: ...bly M5 x 12 Bolt M5 x 20 Bolt M6 x 12 Bolt ST4 2 x 9 5 Bolt Qty 4 Qty 20 Qty 4 Qty 16 Qty 4 AA CC DD EE BB 7 A 6 pcs ASSEMBLY INSTRUCTIONS STEP 6 Attach base frame 11 to all four legs with 4 M5x20 bolts C ssembly M5 x 12 Bolt M5 x 20 Bolt M6 x 12 Bolt ST4 2 x 9 5 Bolt Qty 20 Qty 4 Qty 16 Qty 4 CC DD EE BB C 4 pcs 4 5 FR BR ...

Страница 9: ...to door 9 STEP 8 Attach door 9 to front left leg 8 assembly with 4 ST4 2x9 5 bolts D Note With the help of a friend turn the gas fire table into upright position after this step is finished 0 Bolt M6 x 12 Bolt ST4 2 x 9 5 Bolt 4 Qty 16 Qty 4 DD EE D 4 pcs 8 FL ...

Страница 10: ...S STEP 9 Peel and stick the 16 cushion pads 13 on to the table top frame 1 Note Before applying the adhesive cushion pads be sure to wipe down the metal surface and make sure it is free of any dust or debris STEP 10 Put four ceramic tiles 12 on table top frame 1 1 1 ...

Страница 11: ...o the burning area in the middle of the table top Place the cover lid 6 onto the table top when the gas fire table is not in use Note To avoid ignition failure do not cover the flame orifice with lava rocks see page 13 STEP 12 Connect the gas cylinder see next page ...

Страница 12: ...e a STEP 14a If the connection is leaking bubbles will start to grow in the soapy solution If this happens shut off the gas supply at the cylinder NS STEP 13 Use a solution of soapy water dishwashing liquid and water is fine Brush it on or use a spray bottle as shown in the drawing Ensure the connections have a good coating STEP If the in the supply STEP 14b Tighten the connections using a crescent...

Страница 13: ...creen when placing the lava rocks into the fire table Always keep ignition screen visible WARNING This screen must be clear and free of obstructions at all times to ensure proper operation DO NOT place Lava Rocks on the screen Keep screen clear Screen Correct Incorrect GAS CONNECTION INSTRUCTIONS t then repeat STEP 14c The connection is gas tight when no bubbles grow around the gas connection ...

Страница 14: ...t the electrode fire table can be lit by a long match Move lava rocks to gain access to the burner DO NOT touch unless completely cool Wearing heat resistant gloves position long lit match close to burner port DO NOT lean over burner while lighting Push and turn burner control knob to LOW position The burner should light within 5 seconds STORAGE MAINTENANCE To obtain the best performance from your...

Страница 15: ... bends or kinks Sudden drop in gas flow No gas flow Check if gas cylinder is empty If yes replace Excess flow safety valve has been activated Turn the control knob to OFF Close the gas cylinder valve and disconnect the regulator from the cylinder Turn the control knob to HIGH Wait 1 minute Turn the control knob to OFF Reconnect regulator to gas cylinder Open cylinder valve slowly Light appliance a...

Страница 16: ... the sea loss injury or damage occasioned by or as a result of the misuse or abuse negligent handling or if the product has not been installed and used in accordance with the instructions The warranty is void if there is evidence of the product being tampered with by unauthorised persons If the product includes one or a number of accessories only the defective accessory or part will be replaced eg...

Отзывы: