- Controller set to 21°C
- Room temperature detected at 19°C
- Heater working at power level 6 to reach
the set temperature
- Controller set to 21°C
- Room temperature detected at 20°C
- Heater working at power level 3 to as it is close
to the set temperature
OPERATING MODE – TEMPERATURE CONTROL
In this mode (
) the heater is controlled based on
the difference between the set temperature and the
measured room temperature. The heater will automatically
adjust its heat level based on this difference.
Note: When using the heater in temperature control
mode, it is important that the controller is located within
the room or area being heated so the room temperature
is correctly monitored
The set temperature can be adjusted to a higher
temperature by pressing the UP ( ) button or to a lower
temperature by pressing the DOWN ( ) button.
When the temperature is lower than the set temperature,
the heater will operate at its maximum heat output.
As the room temperature gets closer to the set
temperature, the heater will adjust the heat output level
down. Once the room temperature reaches or exceeds
the set temperature, the heater will turn off.
OPERATING MODE – HEAT LEVEL
In this mode (
) the heater is controlled at one
of 6 levels – 1 being the lowest fan speed and heat
output, 6 being the maximum fan speed and heat output.
The heat level can be adjusted to a higher setting
by pressing the UP ( ) button or to a lower setting
by pressing the DOWN ( ) button.
- Heater operating on heat level 1
- Heater operating on heat level 3
- Heater operating on heat level 6