EN
13
■
Only connect the device to a plug
socket with a 16 A fuse that is pro-
perly installed. The mains voltage
must match the technical data of the
device.
The plug socket must also be readily
accessible after connection so that
the connection to the mains can
quickly be isolated.
■
Do not connect the device along with
other consumers with a high wat-
tage to a circuit in order to prevent
overloading and a possible short
circuit (fire). Make sure that the circuit
is designed to handle the power of
the device.
■
Do not use any multiple sockets,
extension cables more than 3 m long
or cable extension reels.
■
The water pressure of the water
supply pipe must be within the limits
which are specified in the “Technical
Data” chapter.
■
Check the device, the connecting
cable and all accessories for damage
prior to installation. Use the device
only if all components are undama-
ged and in working order.
We recommend connecting the water
inlet (10) of the device directly, or via
a quick coupling, to a tap, and not
to a hose.
To ensure it works perfectly,
you should avoid using a power cable or
water supply pipe which is too long.
1. Fit the main device (
1
) on the water
supply connection (preferably a tap).
To do this, insert the medium sealing
ring (
8
) into the water inlet (
10
) and ...
a) ... screw this onto the water supply
connection,
b) ... with a ¾“ thread (e.g. a quick
coupling) insert the large sealing
ring (
9
) into the ¾“ adapter (
3
) and
screw this in between (
Picture C
),
c) ... with a ½“ thread insert the
small sealing ring (
7
) into the
½“ adapter (
2
) and screw this in
between (
Picture C
),
d) ... with other water supply
connections, in addition to the ½“
adapter (
2
) with the sealing ring,
use the universal adapter (
5
) and
the metal clamp (
6
) (
Picture D
).
Screw the universal adapter
into the ½“ adapter. Plug the
other end onto the water supply
connection and fix it in place with
the metal clamp (
6
) by twisting it
tighter.
2. If a quick coupling is to be fitted on
the water outlet (
14
), unscrew the
flow regulator (
13
) and screw in the
¾“ plastic adapter. Screw a standard
quick coupling onto it.
Otherwise skip this step.
3. Open the water supply.
4. Turn the water regulator (
11
) of the
device to water flow (turn it down-
wards until you hear a click) and
check all connections for any leaks.
Fix any leaks.
5.
Only if there are no leaks
should
you plug the mains plug into the plug
socket.
USE
Picture E
shows the possible positions of
the water regulator (
11
) and the corres-
ponding settings:
• When the water regulator is turned
downwards, the flow of cold water
increases.
• When it is turned upwards, the flow
of hot water increases.
The water
temperature drops as the amount of
water flowing in the hot water range
increases.
When the device is operated in the