Magnum 6KL Managed Edge Switch Installation and User Guide
11/09
21
www GarrettCom com
.
.
3.
Find the Transmit (TX) and Receive (RX) markings on the SFP transceiver to
verify the top side of it. Some of the transceiver marks arrow sign for up.
4.
Position the SFP transceiver correctly before insertion, and then insert the SFP
transceiver carefully, until the transceiver connector snap into the place in the
socket
connector.
5.
Connect the Transmit (TX) port on the Magnum PM to the Receive (RX) port
of the remote device. Connect the Receive (RX) port on the PM to the
Transmit (TX) port of the remote device.
The LINK LED on the front of the PM will illuminate and turn Green, when a proper
connection has been established at both ends (and when power is ON in the unit). If
LINK is not lit or OFF after cable connection, the normal cause is improper cable
polarity. Swap the fiber cables at the PM connector and also check the connectivity on
the target device to remedy this situation.
Reconfigure or reboot both of the devices if required.
If connected properly, you can check via (MNS-6K) software for verifying the validity of
SFP Gigabit ports.
3.3
DIN-Rail Mounting the Magnum 6KL
The
Magnum 6KL is designed for use in a
“factory floor” industrial environment. It is available
with an optional DIN-Rail bracket to mount it
securely in a metal factory floor enclosure, maintained
vertically for proper convection cooling of the unit.
The Magnum 6KL requires one DIN-Rail bracket for
secure mounting. This may be ordered as Model #
DIN-RAIL-6KL. See a 6KL viewed from the bottom,
at the rear, with model DIN-RAIL-6KL in place on
the unit.
The DIN Rail bracket is mounted to the
bottom of the 6KL unit, as shown. Four threaded
holes are provided on the bottom of the 6KL for DIN-
Rail mounting purposes. The required four screws are
included with the DIN-Rail bracket, and are no.4-40 x
9/32 PHIL. PAN Head.
To install the 6KL with the DIN-Rail bracket installed, hold the 6KL in the
side vertical position with the bottom out, and with the top moved in toward the DIN-
Rail. Position the DIN bracket over the top of the DIN-Rail. Then, snap the bracket into
holding position by moving the bottom of the 6KL inwards to a vertical position. The
DIN-Rail bracket is heavy duty, and will hold the 6KL securely in position, even with
cabling attached to the unit.