Magnum 6K32 & 6K32T Managed Switch                 Installation and User Guide (12/05) 

 

29 

www  GarrettCom  com

.

.

 
3.4 

Powering the Magnum 6K32T Managed Switch

 

 

The Magnum 6K32T Switches incorporate an internal universal power supply 

and have a recessed male IEC connector for the AC power cord at the left-rear.  A 

manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power 

cord is supplied with each unit shipped within the United States and Canada.         

 

The auto-ranging power supply supports installation environments where the 

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.  

The 32-port units will consume over 30 watts of power typically.  When connecting the 

Ethernet cabling, there is no need to power down the unit.  Individual segments can be 

connected or disconnected without concern for AC power-related problems or damage to 

the unit. 

 

Power supply options are available to suit the 6K32T Switches to special high-

availability communications and/or heavy industrial-grade applications, including: 

   *    -48VDC, 24VDC and 125VDC with single DC input, 

   *    -48VDC, 24VDC and 125VDC with dual-source DC input, 

See the Appendices of this manual for more details.  Use an RFQ for other variations. 

 

3.4.1    Alarm Contacts for monitoring internal power, and Software Traps  

The Alarm Contacts feature, optional on Magnum 6K32T’s, provides two 

Form C Normally Closed (NC) contacts to which the user can attach two sets of status 

monitoring wires at the green terminal block. When this option is present, the terminal 

block for Alarm Contacts is part of the Power Input panel in the Magnum 6K32T case. 

The AC or DC power input connection is in the same panel. A manual On-Off Switch for 

power to the unit is not available on 6K32T units with the Alarm Contacts option, as 

these two features occupy the same space in the case. 

The first NC Alarm Contact (top position) is a “Software Alarm”, operated 

by user settings in the MNS-6K software.  The user can disable the Software Alarm 

feature with a software configuration command if desired. When the Software Alarm is 

enabled, the Form C Normally Closed (NC) contact is held close during normal software 

operation. A user-defined software malfunction, such as an SNMP Trap or a Software 

Security violation or an S-Ring Fault, causes the contact to open and thus trigger an 

alarm in the user’s monitoring system 

The second (bottom position) NC Alarm Contact is held close when there is 

power on the main board inside of the 6K32T.  This provides a “Hardware Alarm” 

because the NC contacts will open when internal power is lost, either from an external 

power down condition or by the failure of the power supply inside of the Magnum 

6K32T Switch. Useful info. about Alarm contacts:  
1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply  
2. The top two pins (1,2) are software operated 
3. The bottom two pins (3,4) are hardware operated 

Содержание Magnum 6K32T

Страница 1: ...i www GarrettCom com Magnum 6K32T Managed Switch Installation and User Guide Hardware User Manual...

Страница 2: ...Personal Hub is a registered trademark of GarrettCom Inc GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Important The Magn...

Страница 3: ...ructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part...

Страница 4: ...s 17 3 0 INSTALLATION 22 3 1 Locating Magnum 6K32T Switches 22 3 2 Connecting Ethernet Media 23 3 2 1 Connecting Fiber Optic ST type twist lock 23 3 2 2 Connecting Fiber Optic SC type Snap In 24 3 2 3...

Страница 5: ...Factor 48 5 2 7 6KP8 MLC Small Form Factor 48 5 2 8 6KP8 45LC Combo factor and RJ 45 Connector 49 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8 PortError Bookmark not 5 2 10 6KP8 45 2MT multi mode FX MTRJ...

Страница 6: ...r ports mixed speed and mixed media types full switching performance Outdoor Ethernet Switches for temperature uncontrolled locations 6 10 100 and 2 100Mb fiber ports can be connected in strings and r...

Страница 7: ...1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking Maximum 10 Mbps Ethernet Segment Lengths Un...

Страница 8: ...d alone or rack mounting Dimensions 1 70in H x 17 0in W x 9 0in D 4 32cm H x 43 2cm W x 22 9cm D Cooling method Fan cooled 3 7 cfm ea Management Console connector DB 9 for RS 232 null modem cable some...

Страница 9: ...r MDIX on RJ 45 The copper daughter board has MDI MDIX Auto crossover on all the RJ 45 ports and eliminate the use of cross over cable between the devices Also port specific user settings such as FDX...

Страница 10: ...km mm FX ST s 6KP6 RJSSC 4 2 module w four RJ 45 ports and two 20km Sgl m FX SC s 6KP6 RJSSCL 4 2 module w four RJ 45 ports and two 40km Sgl m FX SC s 6KP8 MTRJ SFF Fiber module w eight 100Mb mm FX MT...

Страница 11: ...es front panel metal sheet GBIC LXSC10 GBIC transceiver module for use in GBPM xOTX One 1000BASE LX LH port with 1310nm single mode SC 10km fiber connector GBIC LXSC25 GBIC transceiver module for use...

Страница 12: ...ted port module option in modular slot 1 AC Power Cord U S and other 115 VAC only 1 Set of metal Ears for 19 rack mounting 1 Installation and User Guide this manual 1 Product Registration Card Remove...

Страница 13: ...It provides high performance switching services for both smooth streaming and bursty data traffic For redundant LANs it offers S ring Link Loss Learn STP and RSTP Security features include SNMPv3 SSL...

Страница 14: ...2 or two Gb GBPMV 2OTX port modules can be chosen The modular slot may be configured with a Gb module that accepts GBICs The port types configurable using the modular slots allows the 6K32T to effici...

Страница 15: ...ware includes MNS 6K with support for modular ports The modular option with two slots explores this managed switch s extra capability to meet any 10 or 100 or Gigabit requirement effectively satisfyin...

Страница 16: ...alf duplex mode per port through the set up of the software See the Magnum 6K32T MNS Software Manual for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices There are three LED s...

Страница 17: ...arate The LK Link LED indicates ready for operation on that port when lit The blinking ACT Activity LED indicates receiving Activity on that port when lit The 10 100 LED indicates operation at 100Mb s...

Страница 18: ...ur LED s for each RJ 45 port which indicate status the same as described for the 6K8 RJ45 in Section 2 2 3 above The fiber port s LEDs indicate status the same way as described for the SFF fiber modul...

Страница 19: ...onfigured with four Gigabit ports copper or Fiber maximum The Gigabit port option for the modular slot comes in a couple of different configurations The two Gigabit port modules have been offered as G...

Страница 20: ...Flow Control Magnum 6K32T s are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded...

Страница 21: ...abled features For additional information about MNS 6K see the Magnum 6K Series MNS Software User guide in pdf format a separate document normally accessed via your web browser at ftp ftp garrettcom c...

Страница 22: ...There are over 20 different modules in the family to choose from The port modules are normally factory installed and tested but may be changed in the field Rack mounting may be standard or reverse 19...

Страница 23: ...m 6K32T Switch for a VLAN application Equipped with lots of advanced management features the Magnum 6K32T Managed switch is able to handle a VLAN application and provide security and performance in an...

Страница 24: ...ia along with the higher bandwidth Magnum QS5116 Fiber Switch GARRETT Magnum QS5116 PW Managed Fiber Switch Magnum 6K32 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC 1 3 5 10 100 LK F H ACT 10 100 LK...

Страница 25: ...s security features are easily qualified for the application The 48VDC input power option with Dual Source is especially useful in telecom central offices The Magnum 6K32T with two Gigabit ports in th...

Страница 26: ...ach of the two slot add 4 Gigaport to handle the bandwidth requirement and 16 10 100 RJ 45 ports to feed the other needs of equipment connected to the 6K32T The robust Tag based vlan feature will able...

Страница 27: ...Magnum 6K32 6K32T Managed Switch Installation and User Guide 12 05 21 www GarrettCom com Figure 4 A multicast traffic through a 6K32T Switches with Gigabit redundancy...

Страница 28: ...er of 10Amps should shown on top of Rack This section describes installation of the Magnum 6K32T Switches as well as connection of the various Ethernet media types 3 1 Locating Magnum 6K32T Switches T...

Страница 29: ...allations using a PM with ST type fiber connectors This procedure applies to ports using a 6K32T module MST type port 1 Before connecting the fiber optic cable remove the protective dust caps from the...

Страница 30: ...ded The RJ 45 ports of the Magnum 6K32T can be connected to the following two media types 100BASE TX and 10BASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are used...

Страница 31: ...of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK...

Страница 32: ...X Multi mode 2 0 4 1300 62 5 125 19 31 12 4 16 5 7 6KPM SLC 100Mb FX Single Mode 15 0 4 1310 9 125 15 28 11 22 GBIC SXSC 1000Mb Multi mode 0 55 850 62 5 125 50 125 9 5 17 5 5 2 12 5 4 GBIC LXSC10 1000...

Страница 33: ...y mounted on a table top or any suitable horizontal surface They have four rubber feet to provide stability without scratching finished surfaces 3 3 1 Rack mounting for 19 RETMA racks Magnum 6K32T s I...

Страница 34: ...of the Magnum Switch unit They must be ordered as separate line items 3 3 2 Rack mounting Reverse version of the Magnum 6K32T s Not available as of October 2005 The optional Reverse Magnum 6K32T Mode...

Страница 35: ...des two Form C Normally Closed NC contacts to which the user can attach two sets of status monitoring wires at the green terminal block When this option is present the terminal block for Alarm Contact...

Страница 36: ...ower cord and connections for all powers single or dual is unplugged from the chassis before attempting to remove and or replace any PM cards Failure to do so may result in damage to the unit and will...

Страница 37: ...each on the front and rear sides First Remove the front panel screws total 12 as shown in the fig 3 5 1a Once these are removed the front panel can be easily pulled out to the front The top cover can...

Страница 38: ...tical placed Chassis cover of the unit there are one bracket with retaining screws 256 flat head which hold the PM Face plate card slot securely These six screws shown in the picture below are used to...

Страница 39: ...op of the granddaughter board and latch it securely Fig 3 5 2b Granddaughter Board placed in modular slot and secured with three 7 16 stand off s as shown with arrow mark Step 3 The figure here illust...

Страница 40: ...up 6KPM Cards into a Magnum 6K32T 6K32 NOTE When leaving 6KPM slots empty always use a face plate Magnum 6K8 BLNK to cover the slot opening in the front panel This will maintain proper cooling air fl...

Страница 41: ...ing 6KPM Cards To properly remove a 6KPM card from the 6K32T Managed Switch follow the 3 steps below Step 1 Remove chassis cover See procedures in Section 3 5 1 above Caution Be sure the power cord is...

Страница 42: ...idable substance otherwise can cause a failure in the Switch 2 If the PM module in the modular slot is not being installed properly or loose in connection the MNS 6K management software will not boot...

Страница 43: ...information enables a managed station a PC or Console terminal to connect directly to the switch using a straight through cable Note For using Console port to configure the managed switch a serial Nul...

Страница 44: ...er port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Traffic needed for maintaining the operation of the network such as occasional...

Страница 45: ...of the auto negotiation is changed in the managed switch by the manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in the 6K32T Switches will still work The...

Страница 46: ...established for a port or the LINK is re established on a port after being lost temporarily NOTE Some NIC cards only auto negotiate when the computer system that they are in is powered up These are ex...

Страница 47: ...packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6K32T Switch imp...

Страница 48: ...types refer to Section 1 2 Each 6K PM is individually described in the following sections NOTE The port 1 on the RJ 45 ports on all the modules either all RJ 45 ports or used for COMBO module is set...

Страница 49: ...h the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE standard 10Mbps distance limits i e typically 2km at full duplex...

Страница 50: ...bine 4 ST Fiber ports All four fiber ports are ST connectors and configured as 10Mb Half duplex by default for 10Mb fiber and 100Mb Full duplex for the 100Mb fiber The 10Mb ST fiber ports allow the us...

Страница 51: ...ed with 4 dual speed copper ports and 2 Single mode SC type connectors It provides an advantage through combining copper and Fiber functions in one module of the 6K32T Switch supporting four Copper an...

Страница 52: ...connectivity with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed for the copper port which is 100Mbps whe...

Страница 53: ...2 10Mb Multi mode ST Fiber port The 6KP6 RJ10ST is a combo module with two different kinds of fiber flavor with two different speeds The top four ports of MTRJ Small form factor fiber support at 100Mb...

Страница 54: ...ed on 5 2 3 and the LEDs also act similarly 5 2 7 6KP8 MLC 8 ports 100Mbps multi mode LC connector Small Form Factor Magnum 6KP8 MLC is a eight port multi mode fiber LC connector small form factor use...

Страница 55: ...ir segments of any standard length It is equipped with an eight port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to mini...

Страница 56: ...dard for up links using twisted pair wiring i e the transmit and the receive pairs are exchanged 1 transmit 2 transmit 3 receive 6 receive other pins not used 5 2 10 6KP8 45 2MT 6 10 100Mbps RJ 45 and...

Страница 57: ...OTX fiber or RJ 45 whereas the single Gigabit module comes in flavor of G 2 100Mb fiber ports or G 4 10 100 RJ 45 ports as shown in the above figure The GBIC transceiver is fastened using snap in clip...

Страница 58: ...nectors by easily snapped in and out The Gigabit fiber ports are most popular as server to switch and switch to switch applications It supports cable distances up to the IEEE 802 3z standard 1000Mbps...

Страница 59: ...t to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating t...

Страница 60: ...e that when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It...

Страница 61: ...formation Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units sho...

Страница 62: ...on Industrial Applications DC Power Connector 3 terminals GND Input Voltage 20 36 VDC Power Consumption Same as for AC models see Section 1 1 Power Supply Internal 125 VDC Option Industrial Applicatio...

Страница 63: ...the Industrial environment where it is common facilities to operate on 24VDC or 125VDC power The 125VDC solution is mainly used in power utilities such as electrical substations electrical generating...

Страница 64: ...the terminal block B5 0 OPERATION Operation of Magnum 6K32T Switches with the optional 48VDC 24VDC and 125VDC power supply is identical to that of the standard AC powered models B6 0 ORDERING INFORMAT...

Страница 65: ...the standard AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6K32T Switches C3 0 DUAL SOURCE OPTION THEORY OF OPERATION The Du...

Страница 66: ...a threaded post with a 6 nut The Dual Source terminal block for the 24VDC and 125VDC are similar Figure C5 0 48VDC Dual Source wiring connections to the External Terminal Block on a Magnum 48VDC with...

Страница 67: ...able to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block C6 0 ORDERING INFORMATION To order the optional Dual Source 48VDC power supply factory install...

Отзывы: