Magnum 6K32 & 6K32T Managed Switch Installation and User Guide (12/05)
26
www GarrettCom com
.
.
Fiber
Port
Module
Speed,
Std.
Mode
Std.
km
fdx
(hdx)
Wave
-
length
nm
Cable
Size
µ
m
X’mitr
Output
P
T ,
dB
R’cvr
Sens.
P
R ,
dB
Worst
OPB,
dB
Worst*
distance
Km, fdx
typical
OPB,
dB
typical*
distance
Km, fdx
6KP4-
F10ST
10Mb
FL
Multi-
Mode
2
(2)
850
62.5/125
100/140
50/125
-15.0
-9.5
-19.5
-31
-31
-31
14
19.5
19.5
5
5.9
3.4
17
23.5
13.5
6
7
4.8
6KPM-
MST, MSC
100Mb
FX
Multi-
mode
2
(0.4)
1300
62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
14
12
5
4
6KPM-
SS
C
100Mb
FX
Single-
mode
18+
(0.4) 1300
9/125 -15 -31 14
28
17.5
35
6KPM-
SSCL
100Mb
FX
Single-
mode
40
(0.4) 1300
9/125 -5 -34
29
58
32.5
65
6KPM-
MTRJ
100Mb
FX
Multi-
mode
2
(0.4)
1300
62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
6KPM-
MLC
100Mb
FX
Multi-
mode
2
(0.4) 1300 62.5/125
-19 -31 12
4
16
5.7
6KPM-
SLC
100Mb
FX
Single-
Mode
15+
(0.4)
1310
9/125 -15 -28 11
22
-
-
GBIC-
SXSC
1000Mb Multi-
mode
0.55
850 62.5/125
50/125
-9.5 -17 5.5
2
12.5
4
GBIC-
LXSC10
1000Mb Single-
mode
10
1300
9/125
-9.5 -20
8.5
17
10.5
21
GBIC-
LXSC25
1000Mb Single-
mode
25
1550
9/125
-4.0 -21
15
37.5 17.5
43
GBIC-
ZXSC40
1000Mb Single-
mode
40
1550
9/125
-4.0 -21
15
60 17.5
70
GBIC-
ZXSC70
1000Mb Single-
mode
70
1550
9/125
-3.0 -23
18
90 20.5
102
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed
over long distances (i.e., in excess of approx. 400 meters) can be achieved
only
if the following factors are both applied:
•
The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
and
•
The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)