Magnum 3000 Stackable Hubs Installation and User Guide (07/06)
2
www GarrettCom com
.
.
DC Power Supply (Options)
-48VDC Power
Input Voltage : 36 to 72 VDC
24VDC Power
Input Voltage : 20 to 36VDC
125VDC Power
Input Voltage : 120 to 300VDC
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above
For Dual Source and Redundant DC for –48VDC, 24VDC Power &
125VDC supply options (Optional), see Appendices.
Packaging
Enclosures: High strength sheet metal, suitable for wiring closet
shelf, rack or table-top mounting.
Dimensions: Models 3024, 3012, 3000-AGT: 9.0 in x 17.0 in x 1.75 in
(22.9 cm x 43.2 cm x 4.45 cm)
Weight: Model 3024: 5.0 lbs (2.3 Kg), Model 3012 and
3000-AGT:4.0 lbs (1.8 Kg)
Cooling method: Models 3024, 3012, 3000-AGT: Convection except
3012 and 3024 w/ embedded agent: Fan cooled, internal @ 7cfm
LED Indicators on Chassis Front
PWR
- Power, Green LED, steady on when AC power is applied.
LINK
- (Models 3024 & 3012) Per RJ-45 port, Steady On when twisted
pair link is operational, flashing if the port is partitioned by hardware
RX
- (Models 3024 and 3012) Per RJ-45 port, Receive, Green LED,
blinks to indicate activity of data being received on the port.
Agency
Approvals
UL Listed (UL 1950), cUL, CE
Emissions: meets FCC Part 15 Class A
Optional: ETSI and NEBS L3 Certified
Warranty
Three years, return to factory
Made in USA