Magnum 3000 Stackable Hubs Installation and User Guide (07/06)
3
www GarrettCom com
.
.
1.1
Specifications - Repeater Port Modules (RPMs); Bonus Ports
RPM Type :
BNC
AUI
DTE
Fiber-mm Fiber-sgl.m
TP*
Front
Access
yes
yes yes yes yes yes
Connector Type
BNC-f DB-15 f DB-15 m
Fiber-ST Fiber-ST
RJ-45
Partition
(PART)LED
yes
yes yes yes yes yes
Receive (RX) LED
yes
yes
yes
yes
yes
yes
LINK
LED
n.a.
n.a.
n.a.
yes
yes
yes
Switch on Face Plate yes** n.a.
n.a.
n.a.
n.a.
yes***
“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to
2.0Km.
“Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.
* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded
and shielded twisted pair wiring.
** Internal termination switch for BNC, no "T" connector is required.
*** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,
no crossover cable is required.
1.2
Specifications - Bridge Port Modules (BPMs); Bonus Ports
BPM Type :
BNC
AUI
Fiber
TP*
Connector
Type
BNC(f)
DB-15(f)
ST
RJ-45
Switch on FP
yes**
n.a.
n.a.
yes***
FWD-I
LED yes
yes
yes
yes
FWD-X
LED yes
yes
yes
yes
LINK
LED
n.a.
n.a.
yes
yes
* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded
and shielded twisted pair wiring.
** Internal termination switch for BNC, no "T" connector is required.
*** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,
no crossover cable is required.