5.1.2
10TS2-RJ45, two 10/100Mb RJ45 ports (use in Slots A / B)
The 10TS2-RJ45 two-port copper module provides two 10/100Mb switched
RJ45 ports. (see Section 5.1.5 for more details)
5.1.3
10TS2-HSFP, two 100Mb open SFP ports (use in Slots A / B)
The 10TS2-HSFP two port module provides two 100Mb open SFP ports,
supporting distances up to 40km. This module provides the same functions as 10K4-
MLC (see Section 5.1.7 for more details).
SFP Transceivers are available with multimode 1310nm (2km), singlemode
1310nm (20km) and singlemode 1550nm (40km) fiber options, as well as RJ45 copper.
(see Sec. 1.2 of this manual for available part numbers)
5.1.4
IRIGB-TMODULE, two BNC connectors (use in Slot B)
The IRIG-B Timing module provides two BNC connectors (signal-in and
signal-out) to provide IRIG-B timing information to be transmitted to the IRIG-B
enabled serial modules for 10ETS/XTS. This provides the devices connected to the
10ETS/XTS serial module ports in Slots C-J to receive the timing signals and
synchronize their clocking from the IRIG-B signals.
The signal-out port can be used for cascading IRIG-B signals to other IRIG-B
capable devices. The signals used and transmitted are TTL signals. The IRIG-B signals
are propagated on RS232 or RS485 signals.
A low-loss Belden cable is recommended for IRIG-B connections.