Magnum 10ETS / 10XTS Installation and User Guide
06/12
iii
www GarrettCom com
.
.
Complies with FDA radiation performance
standards, 21CFR Subchapter J.
Electrical Safety requirements:
1.
This product is to be installed Only in Restricted Access Areas
(Dedicated Equipment Rooms, Electrical Closets, or the like).
2.
All products shall be installed with a readily accessible disconnect device in
the building installation supply circuit to the product.
3.
This product shall be provided with a maximum 10A DC Listed fuse or
circuit breaker in the supply circuit when connected to a 48V
centralized
source.
4.
The external power supply for DC units shall be Listed, Direct Plug In
power unit, marked Class 2, or listed ITE Power Supply, marked LPS,
which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable
rated output current.
5.
Product does not contain user replaceable fuses. Any internal fuses can
ONLY be replaced by GarrettCom personnel through the RMA process.
6.
The chassis main earthing screw shall be connected to the supply protective
earthing
conductor.
This equipment has the ordering option of being supplied to the purchaser without a
Fiber Optic Class 1 Laser transceiver included. In this case, it is the responsibility of the
purchasing party to apply the proper labeling required to the product, in accordance
with US 21CFR Subchapter J Part 1040, if a transceiver is installed by the purchaser.
(See label example below)