Settings can be made for both Ampere (A) and power (kW).
Recommended setting is the available (A) or (kW) in the electrical
cabinet(s). GTB Twinbox will read the total consumed energy
from the energy meter(s) and reduce the Ampere to the vehicles to
avoid overload of the available Ampere/power.
In cases of multiple GTB Twinboxes connected in a grid, DLM
settings for each box is visible in this meny.
By choosing to not activate DLM on a GTB Twinbox, you will
have a “prioritized” GTB that always provide full power during
charging. Please note that you will risk overload in the electrical
cabinet if you don’t have enough available power.
USER MANUAL
28
EN