714 / 714-P Manual
b. The sender height is the number of receive segments
present in the sender. To determine the length of the
sender, multiply the calibration by 1.5 to get the length in
inches. The senders always auto calibrate to the length that
they are cut, so this diagnostic allows the user to confirm
the length and to make sure that the auto calibration is
working properly.
3. To check the diagnostics, press the button for the tank to be
checked until the display shows “dIA”.
4. Release the button, the display will then change to showing the
signal power diagnostic. This is indicated by a “P” showing on
the left digit, for example ”P26” indicates a 26% signal power.
5. The signal power will show for 4 seconds or until the button
is pressed again. The display will then change to showing the
sender height. This is indicated by a small “h” showing on the
left digit, for example “h 6” indicates that the sender has 6
receive segments, which is 9 inches high.
6. After 4 seconds of showing the height, or when the button is
pressed again, the display resume normal operation.
Troubleshooting Tips:
1. If the panel is unresponsive, try rebooting it by shutting off
the power to it for a few seconds.
2. For dual display console applications, if the consoles diagree
the most likely reason is a bad console ground.