Garnet SEELEVEL II 714 Скачать руководство пользователя страница 1

INSTRUMENTS LTD.

INSTRUMENTS LTD.

Printed in Canada

TM

S

EE

L

EVE

L II

Tank Monitor

MANUAL

IMPORTANT OPERATOR INFORMATION

DATE INSTALLED: _____________________________________________________________

 

Signal Level

Sender Height

Black Water Tank
Grey Water Tank
Fresh Water Tank

  

714

714-P

Содержание SEELEVEL II 714

Страница 1: ... in Canada TM SEELEVEL II Tank Monitor MANUAL IMPORTANT OPERATOR INFORMATION DATE INSTALLED ______________________________________________________________ Signal Level Sender Height Black Water Tank Grey Water Tank Fresh Water Tank 714 714 P ...

Страница 2: ...IONS 5 CHAPTER 4 DISPLAY CALIBRATION 6 CHAPTER 5 SENDER PROGRAMMING 9 CHAPTER 6 INSTALLATION GUIDE 12 NEW OEM INSTALLATIONS ONLY 12 CHAPTER 7 TROUBLESHOOTING GUIDE 18 CHAPTER 8 SERVICE AND WARRANTY INFORMATION 21 CHAPTER 9 SPECIFICATIONS 22 GARNET SEELEVEL II TM Tank Monitor MODEL 714 714 PH 714 714P Manual_v 3 1 22 Aug 14 ...

Страница 3: ...ability and diagnostic capability that have never been available before The 714 will monitor the battery voltage the water and sewer holding tanks the temperature and the LP Gas tank The information is displayed on 5 three digit alpha numeric LED displays In addition the system can display the operating characteristics of each of the tank sending units giving it unsurpassed diagnostic capability C...

Страница 4: ...udge buildup in the tank becomes extreme the gauge will cease to operate the tank will always read empty so by monitoring the signal power the tank can be cleaned before the buildup gets excessive If the tank is more than 12 inches tall two senders can be stacked to allow measurement of levels up to 24 inches The Display The display continuously shows the levels for the fresh grey and black tanks ...

Страница 5: ...display To read the outside temperature The temperature in degrees is continuously shown on the LED display and is updated every 10 seconds If there are 2 temperature senders installed then pressing the button to the right of the temperature display will toggle between the two temperatures The second temperature will be indicated by a decimal point on the right The temperature can be programmed to...

Страница 6: ...te the temperature readouts to degrees F or degrees C 1 Press and hold the bottom button and then the third button 2 The display will show either Set TEP F C t C dun or Set TEP F C t F dun depending on whether degrees F or C is currently shown When this occurs release the buttons 3 To alternate between Fahrenheit and Celsius press any of the top four buttons each time a button is pressed the displ...

Страница 7: ...ttom display will show dun 3 To change the number of senders press the tank button each time the button is pressed the display will store the value 4 When the display shows the correct number of senders press the bottom button this exits the menu and resumes scanning with that tank Each tank will need to be calibrated individually using this procedure To program the LED brightness 1 If the display...

Страница 8: ...nd then the fourth button the display will show CAL LPG HLd 5 SEC and counts down seconds for as long as the buttons are held 3 After holding the buttons for five seconds the display shows Let Go to CAL 4 When this occurs release both buttons the LPG display is now calibrated to 100 the other displays will show Sto Calibration is complete and normal operation resumes 5 The LPG can be recalibrated ...

Страница 9: ... you make an error you have one chance to correct it as described below 6 If the GRY tab has been removed and it should be a black tank sender or if the BLK tab has been removed and it should be a grey tank sender then cut out the recessed grey black correction tab that says GBC next to it This reverses the effect of the grey and black tabs 7 If either the GRY or BLK tabs have been removed and it ...

Страница 10: ...move the tab that says TOP next to it 4 This is all that is required to program the senders for single top or bottom use However if you make an error you have one chance to correct it as described below 5 If the TOP tab has been removed and it should be a single or bottom sender then cut out the recessed top correction tab that says TC next to it This reverses the effect of the top tab 6 Verify th...

Страница 11: ...Page 11 714 714 P Manual ...

Страница 12: ...Pump switch normally open White Orange 22 gauge Pump switch common White Blue 22 gauge Pump switch normally closed Yellow 22 gauge Pump LED 4 Determine where to mount the senders on the tanks They will need to have a flat area on the side of the tank large enough so the whole width of the sender is in contact with the side of the tank all the way from the top to the bottom of the tank Make sure th...

Страница 13: ...rom the bottom of the tank In addition there needs to be a gap of 1 16 to 1 8 to between the two senders Therefore total length of both senders will be tank height 1 4 1 4 1 8 then rounded down to the nearest 1 5 inches The top and bottom senders should be approximately the same length for best results For example if the tank height is 22 then 22 1 4 1 4 1 8 21 3 8 so the total length of both send...

Страница 14: ...Page 14 714 714 P Manual ...

Страница 15: ...s stuck the sender may be damaged by the sharp bending Carefully press the sender down to the tank so that all of the adhesive is contacting the tank wall 12 Connect all the blue wires from the senders together and to the blue wire from the display Connect the black wire from each sender to ground Use Marrette or crimp connectors to fasten the wires together Make sure that the wires from the sende...

Страница 16: ...teristics of the tank with use so the readings may be inaccurate when the tank is empty or almost empty when the system is first tested Once the tank has been filled at least 1 4 full the system will be properly taught and should read correctly after that 16 Calibrate the LPG by filling the tank and following the instructions in the chapter entitled DISPLAY CALIBRATION and the section To calibrate...

Страница 17: ...Page 17 714 714 P Manual Typical Dual Stacked Sender Installation ...

Страница 18: ...nnected the display will show StA In this case change the senders or reprogram the display as required If only a top sender has been connected the display will show nbo indicating that no bottom sender has been received If the tank should only have 1 sender correct the programming on the sender it should not be a top sender 5 If the display has been programmed for dual stacked senders for tall tan...

Страница 19: ... wires together at the sender locations If no short circuit is shown then the wiring is open If the display does show a short circuit then the senders must be bad 3 If a single sender is showing an open try shorting the wiring together right at that sender If a short now shows the sender is bad or not wired properly If no short circuit shows on the display the wiring to that sender is open To revi...

Страница 20: ...the signal power diagnostic This is indicated by a P showing on the left digit for example P26 indicates a 26 signal power 5 The signal power will show for 4 seconds or until the button is pressed again The display will then change to showing the sender height This is indicated by a small h showing on the left digit for example h 6 indicates that the sender has 6 receive segments which is 9 inches...

Страница 21: ...cations LIMITATION ON WARRANTIES These warranties are the only warranties expressed or implied upon which products are sold by Garnet and Garnet makes no warranty of merchantability or fitness for any particular purpose in respect to the products sold Garnet products or parts thereof assumed to be defective by the purchaser within the stipulated warranty period should be returned to the seller loc...

Страница 22: ... high Power requirements Display requires 12 volts from the RV battery the system will function from 11 volts to 16 volts Current drain is less than 200mA Pump switch The pump switch is rated for a maximum of 10 amps The use of a relay is required if more than 10 amps is needed We recommend using a 10 amp fuse inline with the switch Wiring A single two wire conductor required from the display to t...

Страница 23: ...NOTES ...

Страница 24: ......

Страница 25: ......

Отзывы: