Page 8
709-RVC Manual
RV-C Bus Communication:
RV-C is a communications
protocol based on CAN that is
used for control, coordination,
and diagnostics.
Note
: Anyone that intends on
connecting to the RV-C bus
should have a knowledge of the
RV-C specification. For more
information on RV-C protocol go
to: http://www.rv-c.com
The sensors use a default source address of 72 and SPN-ISB
instances are 0 for fresh, 1 for black, 2 for grey and 18 for galley
(depending how the display is equipped). The LPG sensor uses a
default source address of 73 and a SPN-ISB instance of 3.
1. By disabling the LPG or changing the FRESH/GREY/BLACK to
zero senders, you are disabling that sender’s updates over
the RV-C bus as well.
2. The primary display has priority over the RV-C bus to check
levels. The secondary display will wait until the primary
display releases the bus before getting level readings.
3. The RV-C has a 4-pin connector as shown in the red box in
the image above. The connector pins conform to the RV-C
standard.
4. Some displays have a wired connection as shown in the
red box in the image below. If this is what your display has,
connect the wiring according to the following table.
Wire colour
Function
Black
Ground
Blue
CAN Low (-)
White
CAN High (+)
Содержание SeeLeveL II 709-RVC
Страница 16: ...Page 16 709 RVC Manual 710ES AND 710SS SENDER PROGRAMMING...
Страница 17: ...Page 17 709 RVC Manual 710JS SENDER PROGRAMMING...
Страница 20: ...Page 20 709 RVC Manual 710ES AND 710SS SENDER...
Страница 21: ...Page 21 709 RVC Manual 710JS SENDER...
Страница 25: ...Page 25 709 RVC Manual Typical Double Stacked 710ES or 710SS Sender Installation...