Note:
If using two displays (i.e. a primary and a secondary display),
then only the primary display should have a connection to the
LPG tank. If both displays are connected to an LPG tank, then an
incorrect reading will result. The primary display relays LPG levels
to the secondary display through the sender wiring.
To read the battery voltage:
1. Press the
BATT
button and release it, the display will show the
battery voltage on the LED display.
2. If no other button is pressed, then the display will shut down
after about 5 seconds. If the
BATT
button is held down,
the display will continuously recheck the voltage and show
the updated value. The reading may flicker back and forth
between two values, for example, 12.6 and 12.7 volts. This is
normal behavior for a digital voltage display.
3. If another button is pressed before the 5 second time is up
for the
BATT
button, the display will immediately switch to
showing the value for the new button. The 5 second timeout
is restarted every time a button is pressed.
4. There is no hold mode for the battery voltage.
Содержание SeeLeveL II 709-RVC
Страница 16: ...Page 16 709 RVC Manual 710ES AND 710SS SENDER PROGRAMMING...
Страница 17: ...Page 17 709 RVC Manual 710JS SENDER PROGRAMMING...
Страница 20: ...Page 20 709 RVC Manual 710ES AND 710SS SENDER...
Страница 21: ...Page 21 709 RVC Manual 710JS SENDER...
Страница 25: ...Page 25 709 RVC Manual Typical Double Stacked 710ES or 710SS Sender Installation...