TS-1 Operation and Installation Manual
Page 8
Degaussing Instructions:
Step 1
Press power button ON.
Step 2
Lift up on the drawer to unlock it and slide the drawer out
until it stops
Step 3
Place the media into the drawer and push the drawer to the
closed position. Orientation of the media is not important as
long as the drawer closes freely and completely.
Step 4
Press the “Erase” button.
Note:
After approximately 45 seconds, the LCD will read
“Erase Successful Remove Media” indicating that the media
has been degaussed and is ready for removal from the
media drawer.
Step 5
Remove media by lifting up and sliding out the drawer.
Step 6
Insert another hard drive or turn the power off and close the
drawer.
Degaussing Instructions for DLT Media:
Remove the plastic protective cases. Simply follow the degaussing instructions above
for complete erasure.
Note: For DLT media that is to be re-used.
Although the data is completely degaussed in one operation, a second pass rotated at
90 degrees is required to smooth out any magnetic fluctuation.
Note
: If the second
pass is not completed, the tape drive may eject the tape from the tape drive and
indicate that the tape needs cleaning. The second pass at 90 degrees will correct this
condition.
If you have any questions, please call Garner Products, Inc. at 1-800-624-1903 or 916-
784-0200.
First Pass
Second Pass